{"api_version":"1","generated_at":"2026-07-23T14:50:47+00:00","cve":"CVE-2017-17691","urls":{"html":"https://cve.report/CVE-2017-17691","api":"https://cve.report/api/cve/CVE-2017-17691.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2017-17691","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2017-17691"},"summary":{"title":"CVE-2017-17691","description":"Homeputer CL Studio fur HomeMatic 4.0 Rel 160808 and earlier uses cleartext to exchange the username and password between server and client instances, which allows remote attackers to obtain sensitive information via a man in the middle attack.","state":"PUBLIC","assigner":"cve@mitre.org","published_at":"2018-09-07 22:29:00","updated_at":"2019-10-03 00:03:00"},"problem_types":["CWE-522"],"metrics":[],"references":[{"url":"https://www.compass-security.com/fileadmin/Datein/Research/Advisories/CSNC-2017-031_homematic.txt","name":"https://www.compass-security.com/fileadmin/Datein/Research/Advisories/CSNC-2017-031_homematic.txt","refsource":"MISC","tags":["Exploit","Mitigation","Third Party Advisory"],"title":"","mime":"text/plain","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2017-17691","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2017-17691","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2017","cve_id":"17691","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"contronics","cpe5":"homeputer_cl_studio_fur_homematic","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"17691","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"contronics","cpe5":"homeputer_cl_studio_fur_homematic","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"cve@mitre.org","ID":"CVE-2017-17691","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"n/a","version":{"version_data":[{"version_value":"n/a"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Homeputer CL Studio fur HomeMatic 4.0 Rel 160808 and earlier uses cleartext to exchange the username and password between server and client instances, which allows remote attackers to obtain sensitive information via a man in the middle attack."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"n/a"}]}]},"references":{"reference_data":[{"name":"https://www.compass-security.com/fileadmin/Datein/Research/Advisories/CSNC-2017-031_homematic.txt","refsource":"MISC","url":"https://www.compass-security.com/fileadmin/Datein/Research/Advisories/CSNC-2017-031_homematic.txt"}]}},"nvd":{"publishedDate":"2018-09-07 22:29:00","lastModifiedDate":"2019-10-03 00:03:00","problem_types":["CWE-522"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H","attackVector":"NETWORK","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":8.1,"baseSeverity":"HIGH"},"exploitabilityScore":2.2,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:P/I:N/A:N","accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"NONE","availabilityImpact":"NONE","baseScore":4.3},"severity":"MEDIUM","exploitabilityScore":8.6,"impactScore":2.9,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:contronics:homeputer_cl_studio_fur_homematic:*:*:*:*:*:*:*:*","versionEndExcluding":"4.0","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2017","CveId":"17691","Ordinal":"117908","Title":"CVE-2017-17691","CVE":"CVE-2017-17691","Year":"2017"},"notes":[{"CveYear":"2017","CveId":"17691","Ordinal":"1","NoteData":"Homeputer CL Studio fur HomeMatic 4.0 Rel 160808 and earlier uses cleartext to exchange the username and password between server and client instances, which allows remote attackers to obtain sensitive information via a man in the middle attack.","Type":"Description","Title":null},{"CveYear":"2017","CveId":"17691","Ordinal":"2","NoteData":"2018-09-07","Type":"Other","Title":"Published"},{"CveYear":"2017","CveId":"17691","Ordinal":"3","NoteData":"2018-09-07","Type":"Other","Title":"Modified"}]}}}