{"api_version":"1","generated_at":"2026-05-13T11:43:29+00:00","cve":"CVE-2017-17974","urls":{"html":"https://cve.report/CVE-2017-17974","api":"https://cve.report/api/cve/CVE-2017-17974.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2017-17974","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2017-17974"},"summary":{"title":"CVE-2017-17974","description":"BA SYSTEMS BAS Web on BAS920 devices (with Firmware 01.01.00*, HTTPserv 00002, and Script 02.*) and ISC2000 devices allows remote attackers to obtain sensitive information via a request for isc/get_sid_js.aspx or isc/get_sid.aspx, as demonstrated by obtaining administrative access by subsequently using the credential information for the Supervisor/Administrator account.","state":"PUBLISHED","assigner":"mitre","published_at":"2017-12-29 21:29:00","updated_at":"2025-04-20 01:37:25"},"problem_types":["NVD-CWE-noinfo","n/a"],"metrics":[{"version":"3.0","source":"nvd@nist.gov","type":"Primary","score":"9.8","severity":"CRITICAL","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","data":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"}},{"version":"2.0","source":"nvd@nist.gov","type":"Primary","score":"5","severity":"","vector":"AV:N/AC:L/Au:N/C:P/I:N/A:N","data":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:N/A:N","baseScore":5,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"NONE","availabilityImpact":"NONE"}}],"references":[{"url":"http://misteralfa-hack.blogspot.cl/2017/12/ba-system-improper-access-control.html","name":"http://misteralfa-hack.blogspot.cl/2017/12/ba-system-improper-access-control.html","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Exploit","Third Party Advisory"],"title":"Capitan Alfa: BA SYSTEM; “Improper Access Control (Authorization)”.","mime":"text/html","httpstatus":"404","archivestatus":"200"},{"url":"https://github.com/ezelf/baCK_system","name":"https://github.com/ezelf/baCK_system","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory"],"title":"GitHub - ezelf/baCK_system: scada \"ba_system\": improper access control. get passwd","mime":"text/html","httpstatus":"404","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2017-17974","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2017-17974","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"n/a","product":"n/a","version":"affected n/a","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2017","cve_id":"17974","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"basystems","cpe5":"bas920","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"17974","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"basystems","cpe5":"bas920_firmware","cpe6":"01.01.00","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"17974","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"basystems","cpe5":"isc2000","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"17974","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"basystems","cpe5":"isc2000_firmware","cpe6":"01.01.00","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"providerMetadata":{"dateUpdated":"2024-08-05T21:06:49.959Z","orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE"},"references":[{"tags":["x_refsource_MISC","x_transferred"],"url":"http://misteralfa-hack.blogspot.cl/2017/12/ba-system-improper-access-control.html"},{"tags":["x_refsource_MISC","x_transferred"],"url":"https://github.com/ezelf/baCK_system"}],"title":"CVE Program Container"}],"cna":{"affected":[{"product":"n/a","vendor":"n/a","versions":[{"status":"affected","version":"n/a"}]}],"descriptions":[{"lang":"en","value":"BA SYSTEMS BAS Web on BAS920 devices (with Firmware 01.01.00*, HTTPserv 00002, and Script 02.*) and ISC2000 devices allows remote attackers to obtain sensitive information via a request for isc/get_sid_js.aspx or isc/get_sid.aspx, as demonstrated by obtaining administrative access by subsequently using the credential information for the Supervisor/Administrator account."}],"problemTypes":[{"descriptions":[{"description":"n/a","lang":"en","type":"text"}]}],"providerMetadata":{"dateUpdated":"2017-12-29T21:00:00.000Z","orgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","shortName":"mitre"},"references":[{"tags":["x_refsource_MISC"],"url":"http://misteralfa-hack.blogspot.cl/2017/12/ba-system-improper-access-control.html"},{"tags":["x_refsource_MISC"],"url":"https://github.com/ezelf/baCK_system"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"cve@mitre.org","ID":"CVE-2017-17974","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"n/a","version":{"version_data":[{"version_value":"n/a"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"BA SYSTEMS BAS Web on BAS920 devices (with Firmware 01.01.00*, HTTPserv 00002, and Script 02.*) and ISC2000 devices allows remote attackers to obtain sensitive information via a request for isc/get_sid_js.aspx or isc/get_sid.aspx, as demonstrated by obtaining administrative access by subsequently using the credential information for the Supervisor/Administrator account."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"n/a"}]}]},"references":{"reference_data":[{"name":"http://misteralfa-hack.blogspot.cl/2017/12/ba-system-improper-access-control.html","refsource":"MISC","url":"http://misteralfa-hack.blogspot.cl/2017/12/ba-system-improper-access-control.html"},{"name":"https://github.com/ezelf/baCK_system","refsource":"MISC","url":"https://github.com/ezelf/baCK_system"}]}}}},"cveMetadata":{"assignerOrgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","assignerShortName":"mitre","cveId":"CVE-2017-17974","datePublished":"2017-12-29T21:00:00.000Z","dateReserved":"2017-12-29T00:00:00.000Z","dateUpdated":"2024-09-17T02:27:43.984Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"},"nvd":{"publishedDate":"2017-12-29 21:29:00","lastModifiedDate":"2025-04-20 01:37:25","problem_types":["NVD-CWE-noinfo","n/a"],"metrics":{"cvssMetricV30":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:N/A:N","baseScore":5,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"NONE","availabilityImpact":"NONE"},"baseSeverity":"MEDIUM","exploitabilityScore":10,"impactScore":2.9,"acInsufInfo":true,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:basystems:bas920_firmware:01.01.00:*:*:*:*:*:*:*","matchCriteriaId":"01041B98-330D-47BE-8D6C-938A3507E6DF"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:basystems:bas920:-:*:*:*:*:*:*:*","matchCriteriaId":"C3ADFDDE-374C-4A3C-AC31-61A73E24AF66"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:basystems:isc2000_firmware:01.01.00:*:*:*:*:*:*:*","matchCriteriaId":"D5BBF686-8368-4571-9EBB-866B0A3AD3D6"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:basystems:isc2000:-:*:*:*:*:*:*:*","matchCriteriaId":"6D54BD94-6B60-426F-A48A-215C6043326C"}]}]}]},"legacy_mitre":{"record":{"CveYear":"2017","CveId":"17974","Ordinal":"1","Title":"CVE-2017-17974","CVE":"CVE-2017-17974","Year":"2017"},"notes":[{"CveYear":"2017","CveId":"17974","Ordinal":"1","NoteData":"BA SYSTEMS BAS Web on BAS920 devices (with Firmware 01.01.00*, HTTPserv 00002, and Script 02.*) and ISC2000 devices allows remote attackers to obtain sensitive information via a request for isc/get_sid_js.aspx or isc/get_sid.aspx, as demonstrated by obtaining administrative access by subsequently using the credential information for the Supervisor/Administrator account.","Type":"Description","Title":"CVE-2017-17974"},{"CveYear":"2017","CveId":"17974","Ordinal":"2","NoteData":"2017-12-29","Type":"Other","Title":"Published"}]}}}