{"api_version":"1","generated_at":"2026-07-23T22:21:17+00:00","cve":"CVE-2017-3741","urls":{"html":"https://cve.report/CVE-2017-3741","api":"https://cve.report/api/cve/CVE-2017-3741.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2017-3741","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2017-3741"},"summary":{"title":"CVE-2017-3741","description":"In the Lenovo Power Management driver before 1.67.12.24, a local user may alter the trackpoint's firmware and stop the trackpoint from functioning correctly. This issue only affects ThinkPad X1 Carbon 5th generation.","state":"PUBLISHED","assigner":"lenovo","published_at":"2017-06-04 21:29:00","updated_at":"2025-04-20 01:37:25"},"problem_types":["NVD-CWE-noinfo","Alter trackpoint functionality"],"metrics":[{"version":"3.0","source":"nvd@nist.gov","type":"Primary","score":"3.3","severity":"LOW","vector":"CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N","data":{"version":"3.0","vectorString":"CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N","baseScore":3.3,"baseSeverity":"LOW","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"LOW","availabilityImpact":"NONE"}},{"version":"2.0","source":"nvd@nist.gov","type":"Primary","score":"2.1","severity":"","vector":"AV:L/AC:L/Au:N/C:N/I:P/A:N","data":{"version":"2.0","vectorString":"AV:L/AC:L/Au:N/C:N/I:P/A:N","baseScore":2.1,"accessVector":"LOCAL","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"PARTIAL","availabilityImpact":"NONE"}}],"references":[{"url":"https://support.lenovo.com/us/en/product_security/LEN-14440","name":"https://support.lenovo.com/us/en/product_security/LEN-14440","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"],"title":"Local User Can Alter Trackpoint Functionality in Lenovo Power Management Driver - US","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2017-3741","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2017-3741","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Lenovo Group Ltd.","product":"Power Management Driver","version":"affected ThinkPad X1 Carbon 5th Generation running versions 1.67.12.19 through 1.67.12.23","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2017","cve_id":"3741","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"lenovo","cpe5":"power_management","cpe6":"1.67.12.19","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"3741","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"lenovo","cpe5":"power_management","cpe6":"1.67.12.23","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"3741","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"lenovo","cpe5":"thinkpad_x1_carbon_5","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"providerMetadata":{"dateUpdated":"2024-08-05T14:39:40.937Z","orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE"},"references":[{"tags":["x_refsource_CONFIRM","x_transferred"],"url":"https://support.lenovo.com/us/en/product_security/LEN-14440"}],"title":"CVE Program Container"}],"cna":{"affected":[{"product":"Power Management Driver","vendor":"Lenovo Group Ltd.","versions":[{"status":"affected","version":"ThinkPad X1 Carbon 5th Generation running versions 1.67.12.19 through 1.67.12.23"}]}],"datePublic":"2017-04-27T00:00:00.000Z","descriptions":[{"lang":"en","value":"In the Lenovo Power Management driver before 1.67.12.24, a local user may alter the trackpoint's firmware and stop the trackpoint from functioning correctly. This issue only affects ThinkPad X1 Carbon 5th generation."}],"problemTypes":[{"descriptions":[{"description":"Alter trackpoint functionality","lang":"en","type":"text"}]}],"providerMetadata":{"dateUpdated":"2017-06-02T23:57:01.000Z","orgId":"da227ddf-6e25-4b41-b023-0f976dcaca4b","shortName":"lenovo"},"references":[{"tags":["x_refsource_CONFIRM"],"url":"https://support.lenovo.com/us/en/product_security/LEN-14440"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"psirt@lenovo.com","ID":"CVE-2017-3741","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Power Management Driver","version":{"version_data":[{"version_value":"ThinkPad X1 Carbon 5th Generation running versions 1.67.12.19 through 1.67.12.23"}]}}]},"vendor_name":"Lenovo Group Ltd."}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"In the Lenovo Power Management driver before 1.67.12.24, a local user may alter the trackpoint's firmware and stop the trackpoint from functioning correctly. This issue only affects ThinkPad X1 Carbon 5th generation."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"Alter trackpoint functionality"}]}]},"references":{"reference_data":[{"name":"https://support.lenovo.com/us/en/product_security/LEN-14440","refsource":"CONFIRM","url":"https://support.lenovo.com/us/en/product_security/LEN-14440"}]}}}},"cveMetadata":{"assignerOrgId":"da227ddf-6e25-4b41-b023-0f976dcaca4b","assignerShortName":"lenovo","cveId":"CVE-2017-3741","datePublished":"2017-06-03T00:00:00.000Z","dateReserved":"2016-12-16T00:00:00.000Z","dateUpdated":"2024-08-05T14:39:40.937Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"},"nvd":{"publishedDate":"2017-06-04 21:29:00","lastModifiedDate":"2025-04-20 01:37:25","problem_types":["NVD-CWE-noinfo","Alter trackpoint functionality"],"metrics":{"cvssMetricV30":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N","baseScore":3.3,"baseSeverity":"LOW","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"LOW","availabilityImpact":"NONE"},"exploitabilityScore":1.8,"impactScore":1.4}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:L/AC:L/Au:N/C:N/I:P/A:N","baseScore":2.1,"accessVector":"LOCAL","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"PARTIAL","availabilityImpact":"NONE"},"baseSeverity":"LOW","exploitabilityScore":3.9,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:lenovo:power_management:1.67.12.19:*:*:*:*:*:*:*","matchCriteriaId":"3418B80A-8FDA-4442-B8DA-0FE391C9FD53"},{"vulnerable":true,"criteria":"cpe:2.3:a:lenovo:power_management:1.67.12.23:*:*:*:*:*:*:*","matchCriteriaId":"5DEE20CF-C6C5-4602-B352-E08F44D4B19C"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:lenovo:thinkpad_x1_carbon_5:-:*:*:*:*:*:*:*","matchCriteriaId":"0A3B5592-2BC9-449C-A562-D178572716DA"}]}]}]},"legacy_mitre":{"record":{"CveYear":"2017","CveId":"3741","Ordinal":"1","Title":"CVE-2017-3741","CVE":"CVE-2017-3741","Year":"2017"},"notes":[{"CveYear":"2017","CveId":"3741","Ordinal":"1","NoteData":"In the Lenovo Power Management driver before 1.67.12.24, a local user may alter the trackpoint's firmware and stop the trackpoint from functioning correctly. This issue only affects ThinkPad X1 Carbon 5th generation.","Type":"Description","Title":"CVE-2017-3741"},{"CveYear":"2017","CveId":"3741","Ordinal":"2","NoteData":"2017-06-02","Type":"Other","Title":"Published"},{"CveYear":"2017","CveId":"3741","Ordinal":"3","NoteData":"2017-06-02","Type":"Other","Title":"Modified"}]}}}