{"api_version":"1","generated_at":"2026-07-23T08:11:51+00:00","cve":"CVE-2017-5144","urls":{"html":"https://cve.report/CVE-2017-5144","api":"https://cve.report/api/cve/CVE-2017-5144.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2017-5144","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2017-5144"},"summary":{"title":"CVE-2017-5144","description":"An issue was discovered in Carlo Gavazzi VMU-C EM prior to firmware Version A11_U05, and VMU-C PV prior to firmware Version A17. The access control flaw allows access to most application functions without authentication.","state":"PUBLIC","assigner":"ics-cert@hq.dhs.gov","published_at":"2017-02-13 21:59:00","updated_at":"2019-10-03 00:03:00"},"problem_types":["NVD-CWE-noinfo"],"metrics":[],"references":[{"url":"http://www.securityfocus.com/bid/95411","name":"95411","refsource":"BID","tags":["Third Party Advisory","VDB Entry"],"title":"Multiple Carlo Gavazzi Products ICSA-17-012-03 Multiple Security Vulnerabilities","mime":"text/html","httpstatus":"200","archivestatus":"0"},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-17-012-03","name":"https://ics-cert.us-cert.gov/advisories/ICSA-17-012-03","refsource":"MISC","tags":["Third Party Advisory","US Government Resource"],"title":"Carlo Gavazzi VMU-C EM and VMU-C PV | ICS-CERT","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2017-5144","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2017-5144","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2017","cve_id":"5144","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"carlosgavazzi","cpe5":"vmu-c_em","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"5144","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"carlosgavazzi","cpe5":"vmu-c_em","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"5144","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"carlosgavazzi","cpe5":"vmu-c_em_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"5144","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"carlosgavazzi","cpe5":"vmu-c_em_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"5144","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"carlosgavazzi","cpe5":"vmu-c_pv","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"5144","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"carlosgavazzi","cpe5":"vmu-c_pv","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"5144","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"carlosgavazzi","cpe5":"vmu-c_pv_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"5144","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"carlosgavazzi","cpe5":"vmu-c_pv_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","ID":"CVE-2017-5144","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Carlo Gavazzi VMU-C EM and VMU-C PV","version":{"version_data":[{"version_value":"Carlo Gavazzi VMU-C EM and VMU-C PV"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"An issue was discovered in Carlo Gavazzi VMU-C EM prior to firmware Version A11_U05, and VMU-C PV prior to firmware Version A17. The access control flaw allows access to most application functions without authentication."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"Carlo Gavazzi VMU-C EM and VMU-C PV access control flaw"}]}]},"references":{"reference_data":[{"name":"95411","refsource":"BID","url":"http://www.securityfocus.com/bid/95411"},{"name":"https://ics-cert.us-cert.gov/advisories/ICSA-17-012-03","refsource":"MISC","url":"https://ics-cert.us-cert.gov/advisories/ICSA-17-012-03"}]}},"nvd":{"publishedDate":"2017-02-13 21:59:00","lastModifiedDate":"2019-10-03 00:03:00","problem_types":["NVD-CWE-noinfo"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":9.8,"baseSeverity":"CRITICAL"},"exploitabilityScore":3.9,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:P/A:P","accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL","baseScore":7.5},"severity":"HIGH","exploitabilityScore":10,"impactScore":6.4,"acInsufInfo":true,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:carlosgavazzi:vmu-c_em_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:carlosgavazzi:vmu-c_em:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:carlosgavazzi:vmu-c_pv_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:carlosgavazzi:vmu-c_pv:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":{"CveYear":"2017","CveId":"5144","Ordinal":"101644","Title":"CVE-2017-5144","CVE":"CVE-2017-5144","Year":"2017"},"notes":[{"CveYear":"2017","CveId":"5144","Ordinal":"1","NoteData":"An issue was discovered in Carlo Gavazzi VMU-C EM prior to firmware Version A11_U05, and VMU-C PV prior to firmware Version A17. The access control flaw allows access to most application functions without authentication.","Type":"Description","Title":null},{"CveYear":"2017","CveId":"5144","Ordinal":"2","NoteData":"2017-02-13","Type":"Other","Title":"Published"},{"CveYear":"2017","CveId":"5144","Ordinal":"3","NoteData":"2017-02-14","Type":"Other","Title":"Modified"}]}}}