{"api_version":"1","generated_at":"2026-04-23T14:42:15+00:00","cve":"CVE-2017-5157","urls":{"html":"https://cve.report/CVE-2017-5157","api":"https://cve.report/api/cve/CVE-2017-5157.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2017-5157","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2017-5157"},"summary":{"title":"CVE-2017-5157","description":"An issue was discovered in Schneider Electric homeLYnk Controller, LSS100100, all versions prior to V1.5.0. The homeLYnk controller is susceptible to a cross-site scripting attack. User inputs can be manipulated to cause execution of JavaScript code.","state":"PUBLIC","assigner":"ics-cert@hq.dhs.gov","published_at":"2017-02-13 21:59:00","updated_at":"2022-01-31 20:16:00"},"problem_types":["CWE-79"],"metrics":[],"references":[{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-17-019-01","name":"https://ics-cert.us-cert.gov/advisories/ICSA-17-019-01","refsource":"MISC","tags":["Third Party Advisory","US Government Resource"],"title":"ICS-CERT Advisories | ICS-CERT","mime":"text/html","httpstatus":"404","archivestatus":"200"},{"url":"http://www.securityfocus.com/bid/95665","name":"95665","refsource":"BID","tags":["Third Party Advisory","VDB Entry"],"title":"Schneider homeLYnk Controller LSS1001003 CVE-2017-5157 Cross Site Scripting Vulnerability","mime":"text/html","httpstatus":"200","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2017-5157","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2017-5157","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2017","cve_id":"5157","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"schneider-electric","cpe5":"homelynk_controller_lss100100","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"5157","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"schneider_electric","cpe5":"homelynk_controller_lss100100","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"5157","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"schneider_electric","cpe5":"homelynk_controller_lss100100","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"5157","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"schneider_electric","cpe5":"homelynk_controller_lss100100_firmware","cpe6":"1.3.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"5157","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"schneider_electric","cpe5":"homelynk_controller_lss100100_firmware","cpe6":"1.3.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[{"cve":"CVE-2017-5157","qid":"590518","title":"Schneider Electric homeLYnk Controller (Update A) Multiple Vulnerabilities (ICSA-17-019-01A)"}]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","ID":"CVE-2017-5157","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Schneider Electric homeLYnk Controller prior to V1.5.0","version":{"version_data":[{"version_value":"Schneider Electric homeLYnk Controller prior to V1.5.0"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"An issue was discovered in Schneider Electric homeLYnk Controller, LSS100100, all versions prior to V1.5.0. The homeLYnk controller is susceptible to a cross-site scripting attack. User inputs can be manipulated to cause execution of JavaScript code."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"Schneider Electric homeLYnk Controller XSS"}]}]},"references":{"reference_data":[{"name":"95665","refsource":"BID","url":"http://www.securityfocus.com/bid/95665"},{"name":"https://ics-cert.us-cert.gov/advisories/ICSA-17-019-01","refsource":"MISC","url":"https://ics-cert.us-cert.gov/advisories/ICSA-17-019-01"}]}},"nvd":{"publishedDate":"2017-02-13 21:59:00","lastModifiedDate":"2022-01-31 20:16:00","problem_types":["CWE-79"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"CHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"NONE","baseScore":6.1,"baseSeverity":"MEDIUM"},"exploitabilityScore":2.8,"impactScore":2.7},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:N/I:P/A:N","accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"PARTIAL","availabilityImpact":"NONE","baseScore":4.3},"severity":"MEDIUM","exploitabilityScore":8.6,"impactScore":2.9,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:schneider_electric:homelynk_controller_lss100100_firmware:1.3.0:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:schneider-electric:homelynk_controller_lss100100:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":{"CveYear":"2017","CveId":"5157","Ordinal":"101657","Title":"CVE-2017-5157","CVE":"CVE-2017-5157","Year":"2017"},"notes":[{"CveYear":"2017","CveId":"5157","Ordinal":"1","NoteData":"An issue was discovered in Schneider Electric homeLYnk Controller, LSS100100, all versions prior to V1.5.0. The homeLYnk controller is susceptible to a cross-site scripting attack. User inputs can be manipulated to cause execution of JavaScript code.","Type":"Description","Title":null},{"CveYear":"2017","CveId":"5157","Ordinal":"2","NoteData":"2017-02-13","Type":"Other","Title":"Published"},{"CveYear":"2017","CveId":"5157","Ordinal":"3","NoteData":"2017-02-14","Type":"Other","Title":"Modified"}]}}}