{"api_version":"1","generated_at":"2026-07-23T10:40:30+00:00","cve":"CVE-2017-6015","urls":{"html":"https://cve.report/CVE-2017-6015","api":"https://cve.report/api/cve/CVE-2017-6015.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2017-6015","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2017-6015"},"summary":{"title":"CVE-2017-6015","description":"Without quotation marks, any whitespace in the file path for Rockwell Automation FactoryTalk Activation version 4.00.02 remains ambiguous, which may allow an attacker to link to or run a malicious executable. This may allow an authorized, but not privileged local user to execute arbitrary code with elevated privileges on the system. CVSS v3 base score: 8.8, CVSS vector string: (AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H). Rockwell Automation has released a new version of FactoryTalk Activation, Version 4.01, which addresses the identified vulnerability. Rockwell Automation recommends upgrading to the latest version of FactoryTalk Activation, Version 4.01 or later.","state":"PUBLIC","assigner":"ics-cert@hq.dhs.gov","published_at":"2018-05-11 13:29:00","updated_at":"2019-10-09 23:28:00"},"problem_types":["CWE-74"],"metrics":[],"references":[{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-17-047-02","name":"https://ics-cert.us-cert.gov/advisories/ICSA-17-047-02","refsource":"MISC","tags":["Third Party Advisory","US Government Resource"],"title":"Rockwell Automation FactoryTalk Activation | ICS-CERT","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"http://www.securityfocus.com/bid/96996","name":"96996","refsource":"BID","tags":["Third Party Advisory","VDB Entry"],"title":"Rockwell Automation FactoryTalk Activation CVE-2017-6015 Local Privilege Escalation Vulnerability","mime":"text/html","httpstatus":"200","archivestatus":"0"},{"url":"https://rockwellautomation.custhelp.com/app/answers/detail/a_id/939382","name":"https://rockwellautomation.custhelp.com/app/answers/detail/a_id/939382","refsource":"MISC","tags":["Permissions Required","Vendor Advisory"],"title":"This is the Legacy Answer page, redirecting you to the new page.","mime":"text/html","httpstatus":"200","archivestatus":"500"},{"url":"https://www.cve.org/CVERecord?id=CVE-2017-6015","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2017-6015","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2017","cve_id":"6015","vulnerable":"1","versionEndIncluding":"4.00.02","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"rockwellautomation","cpe5":"factorytalk_activation","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","DATE_PUBLIC":"2017-03-21T00:00:00","ID":"CVE-2017-6015","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"FactoryTalk Activation","version":{"version_data":[{"version_value":"FactoryTalk Activation Service, Version 4.00.02 and prior versions."}]}}]},"vendor_name":"Rockwell Automation"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Without quotation marks, any whitespace in the file path for Rockwell Automation FactoryTalk Activation version 4.00.02 remains ambiguous, which may allow an attacker to link to or run a malicious executable. This may allow an authorized, but not privileged local user to execute arbitrary code with elevated privileges on the system. CVSS v3 base score: 8.8, CVSS vector string: (AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H). Rockwell Automation has released a new version of FactoryTalk Activation, Version 4.01, which addresses the identified vulnerability. Rockwell Automation recommends upgrading to the latest version of FactoryTalk Activation, Version 4.01 or later."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"Unquoted search path or element CWE-428"}]}]},"references":{"reference_data":[{"name":"96996","refsource":"BID","url":"http://www.securityfocus.com/bid/96996"},{"name":"https://rockwellautomation.custhelp.com/app/answers/detail/a_id/939382","refsource":"MISC","url":"https://rockwellautomation.custhelp.com/app/answers/detail/a_id/939382"},{"name":"https://ics-cert.us-cert.gov/advisories/ICSA-17-047-02","refsource":"MISC","url":"https://ics-cert.us-cert.gov/advisories/ICSA-17-047-02"}]}},"nvd":{"publishedDate":"2018-05-11 13:29:00","lastModifiedDate":"2019-10-09 23:28:00","problem_types":["CWE-74"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.0","vectorString":"CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:L/AC:L/Au:N/C:C/I:C/A:C","accessVector":"LOCAL","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE","baseScore":7.2},"severity":"HIGH","exploitabilityScore":3.9,"impactScore":10,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:rockwellautomation:factorytalk_activation:*:*:*:*:*:*:*:*","versionEndIncluding":"4.00.02","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2017","CveId":"6015","Ordinal":"102642","Title":"CVE-2017-6015","CVE":"CVE-2017-6015","Year":"2017"},"notes":[{"CveYear":"2017","CveId":"6015","Ordinal":"1","NoteData":"Without quotation marks, any whitespace in the file path for Rockwell Automation FactoryTalk Activation version 4.00.02 remains ambiguous, which may allow an attacker to link to or run a malicious executable. This may allow an authorized, but not privileged local user to execute arbitrary code with elevated privileges on the system. CVSS v3 base score: 8.8, CVSS vector string: (AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H). Rockwell Automation has released a new version of FactoryTalk Activation, Version 4.01, which addresses the identified vulnerability. Rockwell Automation recommends upgrading to the latest version of FactoryTalk Activation, Version 4.01 or later.","Type":"Description","Title":null},{"CveYear":"2017","CveId":"6015","Ordinal":"2","NoteData":"2018-05-11","Type":"Other","Title":"Published"},{"CveYear":"2017","CveId":"6015","Ordinal":"3","NoteData":"2018-05-12","Type":"Other","Title":"Modified"}]}}}