{"api_version":"1","generated_at":"2026-07-23T14:18:56+00:00","cve":"CVE-2017-6020","urls":{"html":"https://cve.report/CVE-2017-6020","api":"https://cve.report/api/cve/CVE-2017-6020.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2017-6020","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2017-6020"},"summary":{"title":"CVE-2017-6020","description":"Leao Consultoria e Desenvolvimento de Sistemas (LCDS) LTDA ME LAquis SCADA software versions prior to version 4.1.0.3237 do not neutralize external input to ensure that users are not calling for absolute path sequences outside of their privilege level.","state":"PUBLIC","assigner":"ics-cert@hq.dhs.gov","published_at":"2018-04-17 14:29:00","updated_at":"2019-10-09 23:28:00"},"problem_types":["CWE-22"],"metrics":[],"references":[{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-17-082-01","name":"https://ics-cert.us-cert.gov/advisories/ICSA-17-082-01","refsource":"MISC","tags":["Third Party Advisory","US Government Resource"],"title":"LCDS - Leão Consultoria e Desenvolvimento de Sistemas LTDA ME LAquis SCADA | ICS-CERT","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"http://www.securityfocus.com/bid/97055","name":"97055","refsource":"BID","tags":["Third Party Advisory","VDB Entry"],"title":"","mime":"text/html","httpstatus":"200","archivestatus":"0"},{"url":"https://www.exploit-db.com/exploits/42885/","name":"42885","refsource":"EXPLOIT-DB","tags":["Third Party Advisory","VDB Entry"],"title":"LAquis SCADA 4.1.0.2385 - Directory Traversal (Metasploit) - Multiple remote Exploit","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2017-6020","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2017-6020","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2017","cve_id":"6020","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"lcds","cpe5":"laquis_scada","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"6020","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"lcds","cpe5":"laquis_scada","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","DATE_PUBLIC":"2017-03-23T00:00:00","ID":"CVE-2017-6020","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"LAquis SCADA software","version":{"version_data":[{"version_value":"versions prior to version 4.1.0.3237"}]}}]},"vendor_name":"LCDS - LeÃ£o Consultoria e Desenvolvimento de Sistemas LTDA ME"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Leao Consultoria e Desenvolvimento de Sistemas (LCDS) LTDA ME LAquis SCADA software versions prior to version 4.1.0.3237 do not neutralize external input to ensure that users are not calling for absolute path sequences outside of their privilege level."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"Path traversal CWE-22"}]}]},"references":{"reference_data":[{"name":"42885","refsource":"EXPLOIT-DB","url":"https://www.exploit-db.com/exploits/42885/"},{"name":"97055","refsource":"BID","url":"http://www.securityfocus.com/bid/97055"},{"name":"https://ics-cert.us-cert.gov/advisories/ICSA-17-082-01","refsource":"MISC","url":"https://ics-cert.us-cert.gov/advisories/ICSA-17-082-01"}]}},"nvd":{"publishedDate":"2018-04-17 14:29:00","lastModifiedDate":"2019-10-09 23:28:00","problem_types":["CWE-22"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"NONE","availabilityImpact":"NONE","baseScore":5.3,"baseSeverity":"MEDIUM"},"exploitabilityScore":3.9,"impactScore":1.4},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:L/Au:S/C:P/I:N/A:N","accessVector":"NETWORK","accessComplexity":"LOW","authentication":"SINGLE","confidentialityImpact":"PARTIAL","integrityImpact":"NONE","availabilityImpact":"NONE","baseScore":4},"severity":"MEDIUM","exploitabilityScore":8,"impactScore":2.9,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:lcds:laquis_scada:*:*:*:*:*:*:*:*","versionEndExcluding":"4.1.0.3237","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2017","CveId":"6020","Ordinal":"102647","Title":"CVE-2017-6020","CVE":"CVE-2017-6020","Year":"2017"},"notes":[{"CveYear":"2017","CveId":"6020","Ordinal":"1","NoteData":"Leao Consultoria e Desenvolvimento de Sistemas (LCDS) LTDA ME LAquis SCADA software versions prior to version 4.1.0.3237 do not neutralize external input to ensure that users are not calling for absolute path sequences outside of their privilege level.","Type":"Description","Title":null},{"CveYear":"2017","CveId":"6020","Ordinal":"2","NoteData":"2018-04-17","Type":"Other","Title":"Published"},{"CveYear":"2017","CveId":"6020","Ordinal":"3","NoteData":"2018-04-18","Type":"Other","Title":"Modified"}]}}}