{"api_version":"1","generated_at":"2026-04-23T05:14:09+00:00","cve":"CVE-2017-6026","urls":{"html":"https://cve.report/CVE-2017-6026","api":"https://cve.report/api/cve/CVE-2017-6026.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2017-6026","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2017-6026"},"summary":{"title":"CVE-2017-6026","description":"A Use of Insufficiently Random Values issue was discovered in Schneider Electric Modicon PLCs Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The session numbers generated by the web application are lacking randomization and are shared between several users. This may allow a current session to be compromised.","state":"PUBLIC","assigner":"ics-cert@hq.dhs.gov","published_at":"2017-06-30 03:29:00","updated_at":"2022-02-02 13:05:00"},"problem_types":["CWE-330"],"metrics":[],"references":[{"url":"http://www.securityfocus.com/bid/97254","name":"97254","refsource":"BID","tags":["Third Party Advisory","VDB Entry"],"title":"Multiple Schneider Electric Modicon Products Weak Cryptography Multiple Security Weaknesses","mime":"text/html","httpstatus":"200","archivestatus":"0"},{"url":"https://www.exploit-db.com/exploits/45918/","name":"45918","refsource":"EXPLOIT-DB","tags":[],"title":"Schneider Electric PLC - Session Calculation Authentication Bypass - Hardware webapps Exploit","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02","name":"https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02","refsource":"MISC","tags":["Third Party Advisory","US Government Resource"],"title":"Schneider Electric Modicon PLCs | ICS-CERT","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2017-6026","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2017-6026","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2017","cve_id":"6026","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"schneider-electric","cpe5":"modicon_m241","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"6026","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"schneider-electric","cpe5":"modicon_m241","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"6026","vulnerable":"1","versionEndIncluding":"4.0.3.20","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"schneider-electric","cpe5":"modicon_m241_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"6026","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"schneider-electric","cpe5":"modicon_m251","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"6026","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"schneider-electric","cpe5":"modicon_m251","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"6026","vulnerable":"1","versionEndIncluding":"4.0.3.20","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"schneider-electric","cpe5":"modicon_m251_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"6026","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"se","cpe5":"modicon_m241","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"6026","vulnerable":"1","versionEndIncluding":"4.0.3.20","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"se","cpe5":"modicon_m241_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"6026","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"se","cpe5":"modicon_m251","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"6026","vulnerable":"1","versionEndIncluding":"4.0.3.20","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"se","cpe5":"modicon_m251_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[{"cve":"CVE-2017-6026","qid":"590487","title":"Schneider Electric Modicon PLCs Multiple Vulnerabilities (ICSA-17-089-02)"}]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","ID":"CVE-2017-6026","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Schneider Electric Modicon PLCs","version":{"version_data":[{"version_value":"Schneider Electric Modicon PLCs"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"A Use of Insufficiently Random Values issue was discovered in Schneider Electric Modicon PLCs Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The session numbers generated by the web application are lacking randomization and are shared between several users. This may allow a current session to be compromised."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-330"}]}]},"references":{"reference_data":[{"name":"https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02","refsource":"MISC","url":"https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02"},{"name":"97254","refsource":"BID","url":"http://www.securityfocus.com/bid/97254"},{"name":"45918","refsource":"EXPLOIT-DB","url":"https://www.exploit-db.com/exploits/45918/"}]}},"nvd":{"publishedDate":"2017-06-30 03:29:00","lastModifiedDate":"2022-02-02 13:05:00","problem_types":["CWE-330"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"NONE","baseScore":9.1,"baseSeverity":"CRITICAL"},"exploitabilityScore":3.9,"impactScore":5.2},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:P/A:N","accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"NONE","baseScore":6.4},"severity":"MEDIUM","exploitabilityScore":10,"impactScore":4.9,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:schneider-electric:modicon_m251_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"4.0.3.20","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:schneider-electric:modicon_m251:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:schneider-electric:modicon_m241_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"4.0.3.20","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:schneider-electric:modicon_m241:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":{"CveYear":"2017","CveId":"6026","Ordinal":"102653","Title":"CVE-2017-6026","CVE":"CVE-2017-6026","Year":"2017"},"notes":[{"CveYear":"2017","CveId":"6026","Ordinal":"1","NoteData":"A Use of Insufficiently Random Values issue was discovered in Schneider Electric Modicon PLCs Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The session numbers generated by the web application are lacking randomization and are shared between several users. This may allow a current session to be compromised.","Type":"Description","Title":null},{"CveYear":"2017","CveId":"6026","Ordinal":"2","NoteData":"2017-06-29","Type":"Other","Title":"Published"},{"CveYear":"2017","CveId":"6026","Ordinal":"3","NoteData":"2018-12-01","Type":"Other","Title":"Modified"}]}}}