{"api_version":"1","generated_at":"2026-07-23T10:16:41+00:00","cve":"CVE-2017-6866","urls":{"html":"https://cve.report/CVE-2017-6866","api":"https://cve.report/api/cve/CVE-2017-6866.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2017-6866","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2017-6866"},"summary":{"title":"CVE-2017-6866","description":"A vulnerability was discovered in Siemens XHQ server 4 and 5 (4 before V4.7.1.3 and 5 before V5.0.0.2) that could allow an authenticated low-privileged remote user to gain read access to data in the XHQ solution exceeding his configured permission level.","state":"PUBLISHED","assigner":"siemens","published_at":"2017-08-07 23:29:00","updated_at":"2025-04-20 01:37:25"},"problem_types":["CWE-284","NVD-CWE-noinfo","CWE-284 CWE-284: Improper Access Control"],"metrics":[{"version":"3.0","source":"nvd@nist.gov","type":"Primary","score":"6.5","severity":"MEDIUM","vector":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N","data":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N","baseScore":6.5,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE"}},{"version":"2.0","source":"nvd@nist.gov","type":"Primary","score":"4","severity":"","vector":"AV:N/AC:L/Au:S/C:P/I:N/A:N","data":{"version":"2.0","vectorString":"AV:N/AC:L/Au:S/C:P/I:N/A:N","baseScore":4,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"SINGLE","confidentialityImpact":"PARTIAL","integrityImpact":"NONE","availabilityImpact":"NONE"}}],"references":[{"url":"http://www.securityfocus.com/bid/99247","name":"http://www.securityfocus.com/bid/99247","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","VDB Entry"],"title":"Siemens XHQ CVE-2017-6866 Access Bypass Vulnerability","mime":"text/html","httpstatus":"200","archivestatus":"0"},{"url":"https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-945660.pdf","name":"https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-945660.pdf","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"],"title":"Siemens","mime":"application/pdf","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2017-6866","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2017-6866","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"n/a","product":"XHQ 4 (All versions before V4.7.1.3), XHQ 5 (All versions before V5.0.0.2)","version":"affected XHQ 4 (All versions before V4.7.1.3), XHQ 5 (All versions before V5.0.0.2)","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2017","cve_id":"6866","vulnerable":"1","versionEndIncluding":"4.7.1.2","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"xhq_server","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"6866","vulnerable":"1","versionEndIncluding":"5.0.0.1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"xhq_server","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"providerMetadata":{"dateUpdated":"2024-08-05T15:41:17.651Z","orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE"},"references":[{"name":"99247","tags":["vdb-entry","x_refsource_BID","x_transferred"],"url":"http://www.securityfocus.com/bid/99247"},{"tags":["x_refsource_CONFIRM","x_transferred"],"url":"https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-945660.pdf"}],"title":"CVE Program Container"}],"cna":{"affected":[{"product":"XHQ 4 (All versions before V4.7.1.3), XHQ 5 (All versions before V5.0.0.2)","vendor":"n/a","versions":[{"status":"affected","version":"XHQ 4 (All versions before V4.7.1.3), XHQ 5 (All versions before V5.0.0.2)"}]}],"datePublic":"2017-08-07T00:00:00.000Z","descriptions":[{"lang":"en","value":"A vulnerability was discovered in Siemens XHQ server 4 and 5 (4 before V4.7.1.3 and 5 before V5.0.0.2) that could allow an authenticated low-privileged remote user to gain read access to data in the XHQ solution exceeding his configured permission level."}],"problemTypes":[{"descriptions":[{"cweId":"CWE-284","description":"CWE-284: Improper Access Control","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2017-08-08T09:57:01.000Z","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","shortName":"siemens"},"references":[{"name":"99247","tags":["vdb-entry","x_refsource_BID"],"url":"http://www.securityfocus.com/bid/99247"},{"tags":["x_refsource_CONFIRM"],"url":"https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-945660.pdf"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"productcert@siemens.com","ID":"CVE-2017-6866","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"XHQ 4 (All versions before V4.7.1.3), XHQ 5 (All versions before V5.0.0.2)","version":{"version_data":[{"version_value":"XHQ 4 (All versions before V4.7.1.3), XHQ 5 (All versions before V5.0.0.2)"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"A vulnerability was discovered in Siemens XHQ server 4 and 5 (4 before V4.7.1.3 and 5 before V5.0.0.2) that could allow an authenticated low-privileged remote user to gain read access to data in the XHQ solution exceeding his configured permission level."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-284: Improper Access Control"}]}]},"references":{"reference_data":[{"name":"99247","refsource":"BID","url":"http://www.securityfocus.com/bid/99247"},{"name":"https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-945660.pdf","refsource":"CONFIRM","url":"https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-945660.pdf"}]}}}},"cveMetadata":{"assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","assignerShortName":"siemens","cveId":"CVE-2017-6866","datePublished":"2017-08-07T23:00:00.000Z","dateReserved":"2017-03-13T00:00:00.000Z","dateUpdated":"2024-08-05T15:41:17.651Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"},"nvd":{"publishedDate":"2017-08-07 23:29:00","lastModifiedDate":"2025-04-20 01:37:25","problem_types":["CWE-284","NVD-CWE-noinfo","CWE-284 CWE-284: Improper Access Control"],"metrics":{"cvssMetricV30":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N","baseScore":6.5,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE"},"exploitabilityScore":2.8,"impactScore":3.6}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:S/C:P/I:N/A:N","baseScore":4,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"SINGLE","confidentialityImpact":"PARTIAL","integrityImpact":"NONE","availabilityImpact":"NONE"},"baseSeverity":"MEDIUM","exploitabilityScore":8,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:xhq_server:*:*:*:*:*:*:*:*","versionEndIncluding":"4.7.1.2","matchCriteriaId":"3DF7D4D0-548A-4E45-A279-FA2A0F32EA9C"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:xhq_server:*:*:*:*:*:*:*:*","versionEndIncluding":"5.0.0.1","matchCriteriaId":"0204E2A9-AA1D-42D8-A5B3-939DB37D581C"}]}]}]},"legacy_mitre":{"record":{"CveYear":"2017","CveId":"6866","Ordinal":"1","Title":"CVE-2017-6866","CVE":"CVE-2017-6866","Year":"2017"},"notes":[{"CveYear":"2017","CveId":"6866","Ordinal":"1","NoteData":"A vulnerability was discovered in Siemens XHQ server 4 and 5 (4 before V4.7.1.3 and 5 before V5.0.0.2) that could allow an authenticated low-privileged remote user to gain read access to data in the XHQ solution exceeding his configured permission level.","Type":"Description","Title":"CVE-2017-6866"},{"CveYear":"2017","CveId":"6866","Ordinal":"2","NoteData":"2017-08-07","Type":"Other","Title":"Published"},{"CveYear":"2017","CveId":"6866","Ordinal":"3","NoteData":"2017-08-08","Type":"Other","Title":"Modified"}]}}}