{"api_version":"1","generated_at":"2026-07-23T18:57:04+00:00","cve":"CVE-2017-6867","urls":{"html":"https://cve.report/CVE-2017-6867","api":"https://cve.report/api/cve/CVE-2017-6867.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2017-6867","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2017-6867"},"summary":{"title":"CVE-2017-6867","description":"A vulnerability was discovered in Siemens SIMATIC WinCC (V7.3 before Upd 11 and V7.4 before SP1), SIMATIC WinCC Runtime Professional (V13 before SP2 and V14 before SP1), SIMATIC WinCC (TIA Portal) Professional (V13 before SP2 and V14 before SP1) that could allow an authenticated, remote attacker who is member of the \"administrators\" group to crash services by sending specially crafted messages to the DCOM interface.","state":"PUBLISHED","assigner":"siemens","published_at":"2017-05-11 10:29:00","updated_at":"2025-04-20 01:37:25"},"problem_types":["CWE-787","CWE-20","CWE-787 CWE-787: Out-of-bounds Write"],"metrics":[{"version":"3.0","source":"nvd@nist.gov","type":"Primary","score":"4.9","severity":"MEDIUM","vector":"CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H","data":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H","baseScore":4.9,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"}},{"version":"2.0","source":"nvd@nist.gov","type":"Primary","score":"4","severity":"","vector":"AV:N/AC:L/Au:S/C:N/I:N/A:P","data":{"version":"2.0","vectorString":"AV:N/AC:L/Au:S/C:N/I:N/A:P","baseScore":4,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"SINGLE","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"PARTIAL"}}],"references":[{"url":"https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-156872.pdf","name":"https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-156872.pdf","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"],"title":"Siemens","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-523365.pdf","name":"https://cert-portal.siemens.com/productcert/pdf/ssa-523365.pdf","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":[],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"200"},{"url":"http://www.securityfocus.com/bid/98368","name":"http://www.securityfocus.com/bid/98368","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","VDB Entry"],"title":"Malformed Request","mime":"text/html","httpstatus":"200","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2017-6867","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2017-6867","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"n/a","product":"Siemens SIMATIC WinCC","version":"affected Siemens SIMATIC WinCC","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2017","cve_id":"6867","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"7.3","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"6867","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc","cpe6":"7.4","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"6867","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc_runtime","cpe6":"13","cpe7":"sp1","cpe8":"*","cpe9":"*","cpe10":"professional","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"6867","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc_runtime","cpe6":"14","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"professional","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"6867","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc_\\(tia_portal\\)","cpe6":"13","cpe7":"sp1","cpe8":"*","cpe9":"*","cpe10":"professional","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"6867","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_wincc_\\(tia_portal\\)","cpe6":"14","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"professional","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"providerMetadata":{"dateUpdated":"2024-08-05T15:41:17.675Z","orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE"},"references":[{"name":"98368","tags":["vdb-entry","x_refsource_BID","x_transferred"],"url":"http://www.securityfocus.com/bid/98368"},{"tags":["x_refsource_CONFIRM","x_transferred"],"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-523365.pdf"},{"tags":["x_refsource_CONFIRM","x_transferred"],"url":"https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-156872.pdf"}],"title":"CVE Program Container"}],"cna":{"affected":[{"product":"Siemens SIMATIC WinCC","vendor":"n/a","versions":[{"status":"affected","version":"Siemens SIMATIC WinCC"}]}],"datePublic":"2017-05-10T00:00:00.000Z","descriptions":[{"lang":"en","value":"A vulnerability was discovered in Siemens SIMATIC WinCC (V7.3 before Upd 11 and V7.4 before SP1), SIMATIC WinCC Runtime Professional (V13 before SP2 and V14 before SP1), SIMATIC WinCC (TIA Portal) Professional (V13 before SP2 and V14 before SP1) that could allow an authenticated, remote attacker who is member of the \"administrators\" group to crash services by sending specially crafted messages to the DCOM interface."}],"problemTypes":[{"descriptions":[{"cweId":"CWE-787","description":"CWE-787: Out-of-bounds Write","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2018-06-13T09:57:01.000Z","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","shortName":"siemens"},"references":[{"name":"98368","tags":["vdb-entry","x_refsource_BID"],"url":"http://www.securityfocus.com/bid/98368"},{"tags":["x_refsource_CONFIRM"],"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-523365.pdf"},{"tags":["x_refsource_CONFIRM"],"url":"https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-156872.pdf"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"productcert@siemens.com","ID":"CVE-2017-6867","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Siemens SIMATIC WinCC","version":{"version_data":[{"version_value":"Siemens SIMATIC WinCC"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"A vulnerability was discovered in Siemens SIMATIC WinCC (V7.3 before Upd 11 and V7.4 before SP1), SIMATIC WinCC Runtime Professional (V13 before SP2 and V14 before SP1), SIMATIC WinCC (TIA Portal) Professional (V13 before SP2 and V14 before SP1) that could allow an authenticated, remote attacker who is member of the \"administrators\" group to crash services by sending specially crafted messages to the DCOM interface."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-787: Out-of-bounds Write"}]}]},"references":{"reference_data":[{"name":"98368","refsource":"BID","url":"http://www.securityfocus.com/bid/98368"},{"name":"https://cert-portal.siemens.com/productcert/pdf/ssa-523365.pdf","refsource":"CONFIRM","url":"https://cert-portal.siemens.com/productcert/pdf/ssa-523365.pdf"},{"name":"https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-156872.pdf","refsource":"CONFIRM","url":"https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-156872.pdf"}]}}}},"cveMetadata":{"assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","assignerShortName":"siemens","cveId":"CVE-2017-6867","datePublished":"2017-05-11T10:00:00.000Z","dateReserved":"2017-03-13T00:00:00.000Z","dateUpdated":"2024-08-05T15:41:17.675Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"},"nvd":{"publishedDate":"2017-05-11 10:29:00","lastModifiedDate":"2025-04-20 01:37:25","problem_types":["CWE-787","CWE-20","CWE-787 CWE-787: Out-of-bounds Write"],"metrics":{"cvssMetricV30":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H","baseScore":4.9,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"},"exploitabilityScore":1.2,"impactScore":3.6}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:S/C:N/I:N/A:P","baseScore":4,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"SINGLE","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":8,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:simatic_wincc:7.3:*:*:*:*:*:*:*","matchCriteriaId":"8D6229A2-9B8E-4F76-8425-589D2CE58B16"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:simatic_wincc:7.4:*:*:*:*:*:*:*","matchCriteriaId":"F64B795A-7E66-49AE-BE40-E8EEAC12D280"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):13:sp1:*:*:professional:*:*:*","matchCriteriaId":"F8FA6B17-FA61-44FC-BAA7-AAC63ECBD996"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):14:*:*:*:professional:*:*:*","matchCriteriaId":"B0E21465-76ED-4803-A40A-539500B993F9"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:simatic_wincc_runtime:13:sp1:*:*:professional:*:*:*","matchCriteriaId":"57CE0216-AA81-416B-88D2-3321D2A2A16D"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:simatic_wincc_runtime:14:*:*:*:professional:*:*:*","matchCriteriaId":"D8893E54-CF26-448A-9C32-90E5F8D8CC84"}]}]}]},"legacy_mitre":{"record":{"CveYear":"2017","CveId":"6867","Ordinal":"1","Title":"CVE-2017-6867","CVE":"CVE-2017-6867","Year":"2017"},"notes":[{"CveYear":"2017","CveId":"6867","Ordinal":"1","NoteData":"A vulnerability was discovered in Siemens SIMATIC WinCC (V7.3 before Upd 11 and V7.4 before SP1), SIMATIC WinCC Runtime Professional (V13 before SP2 and V14 before SP1), SIMATIC WinCC (TIA Portal) Professional (V13 before SP2 and V14 before SP1) that could allow an authenticated, remote attacker who is member of the \"administrators\" group to crash services by sending specially crafted messages to the DCOM interface.","Type":"Description","Title":"CVE-2017-6867"},{"CveYear":"2017","CveId":"6867","Ordinal":"2","NoteData":"2017-05-11","Type":"Other","Title":"Published"},{"CveYear":"2017","CveId":"6867","Ordinal":"3","NoteData":"2018-06-13","Type":"Other","Title":"Modified"}]}}}