{"api_version":"1","generated_at":"2026-06-13T18:10:55+00:00","cve":"CVE-2017-7898","urls":{"html":"https://cve.report/CVE-2017-7898","api":"https://cve.report/api/cve/CVE-2017-7898.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2017-7898","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2017-7898"},"summary":{"title":"CVE-2017-7898","description":"An Improper Restriction of Excessive Authentication Attempts issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. There are no penalties for repeatedly entering incorrect passwords.","state":"PUBLISHED","assigner":"icscert","published_at":"2017-06-30 03:29:00","updated_at":"2026-06-03 14:16:19"},"problem_types":["CWE-307","CWE-307 CWE-307"],"metrics":[{"version":"3.1","source":"ADP","type":"DECLARED","score":"9.8","severity":"CRITICAL","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","data":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":9.8,"baseSeverity":"CRITICAL","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"}},{"version":"3.1","source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","score":"9.8","severity":"CRITICAL","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"}},{"version":"3.0","source":"nvd@nist.gov","type":"Primary","score":"9.8","severity":"CRITICAL","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","data":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"}},{"version":"2.0","source":"nvd@nist.gov","type":"Primary","score":"5","severity":"","vector":"AV:N/AC:L/Au:N/C:P/I:N/A:N","data":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:N/A:N","baseScore":5,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"NONE","availabilityImpact":"NONE"}}],"references":[{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-17-115-04","name":"https://ics-cert.us-cert.gov/advisories/ICSA-17-115-04","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Patch","Third Party Advisory","US Government Resource"],"title":"Rockwell Automation Allen-Bradley MicroLogix 1100 and 1400 | CISA","mime":"text/html","httpstatus":"200","archivestatus":"0"},{"url":"http://www.securitytracker.com/id/1038546","name":"http://www.securitytracker.com/id/1038546","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":[],"title":"Rockwell Automation MicroLogix PLC Multiple Flaws Let Remote Users Guess Passwords, Replay Commands, and Deny Service and Let Local Users Obtain Passwords - SecurityTracker","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2017-7898","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2017-7898","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"n/a","product":"Rockwell Automation Allen-Bradley MicroLogix 1100 and 1400","version":"affected Rockwell Automation Allen-Bradley MicroLogix 1100 and 1400","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2017","cve_id":"7898","vulnerable":"1","versionEndIncluding":"16.000","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"rockwellautomation","cpe5":"1763-l16awa_series_a","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"7898","vulnerable":"1","versionEndIncluding":"16.000","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"rockwellautomation","cpe5":"1763-l16awa_series_b","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"7898","vulnerable":"1","versionEndIncluding":"16.000","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"rockwellautomation","cpe5":"1763-l16bbb_series_a","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"7898","vulnerable":"1","versionEndIncluding":"16.000","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"rockwellautomation","cpe5":"1763-l16bbb_series_b","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"7898","vulnerable":"1","versionEndIncluding":"16.000","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"rockwellautomation","cpe5":"1763-l16bwa_series_a","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"7898","vulnerable":"1","versionEndIncluding":"16.000","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"rockwellautomation","cpe5":"1763-l16bwa_series_b","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"7898","vulnerable":"1","versionEndIncluding":"16.000","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"rockwellautomation","cpe5":"1763-l16dwd_series_a","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"7898","vulnerable":"1","versionEndIncluding":"16.000","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"rockwellautomation","cpe5":"1763-l16dwd_series_b","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"7898","vulnerable":"1","versionEndIncluding":"16.000","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"rockwellautomation","cpe5":"1766-l32awaa_series_a","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"7898","vulnerable":"1","versionEndIncluding":"16.000","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"rockwellautomation","cpe5":"1766-l32awaa_series_b","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"7898","vulnerable":"1","versionEndIncluding":"16.000","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"rockwellautomation","cpe5":"1766-l32awa_series_a","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"7898","vulnerable":"1","versionEndIncluding":"16.000","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"rockwellautomation","cpe5":"1766-l32awa_series_b","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"7898","vulnerable":"1","versionEndIncluding":"16.000","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"rockwellautomation","cpe5":"1766-l32bwaa_series_a","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"7898","vulnerable":"1","versionEndIncluding":"16.000","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"rockwellautomation","cpe5":"1766-l32bwaa_series_b","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"7898","vulnerable":"1","versionEndIncluding":"16.000","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"rockwellautomation","cpe5":"1766-l32bwa_series_a","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"7898","vulnerable":"1","versionEndIncluding":"16.000","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"rockwellautomation","cpe5":"1766-l32bwa_series_b","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"7898","vulnerable":"1","versionEndIncluding":"16.000","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"rockwellautomation","cpe5":"1766-l32bxba_series_a","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"7898","vulnerable":"1","versionEndIncluding":"16.000","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"rockwellautomation","cpe5":"1766-l32bxba_series_b","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"7898","vulnerable":"1","versionEndIncluding":"16.000","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"rockwellautomation","cpe5":"1766-l32bxb_series_a","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"7898","vulnerable":"1","versionEndIncluding":"16.000","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"rockwellautomation","cpe5":"1766-l32bxb_series_b","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"7898","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"rockwellautomation","cpe5":"ab_micrologix_controller","cpe6":"1100","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"7898","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"rockwellautomation","cpe5":"ab_micrologix_controller","cpe6":"1400","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":{"cve_year":"2017","cve_id":"7898","cve":"CVE-2017-7898","epss":"0.011380000","percentile":"0.787410000","score_date":"2026-06-08","updated_at":"2026-06-09 00:12:52"},"legacy_qids":[]},"source_records":{"cve_program":{"containers":{"adp":[{"providerMetadata":{"dateUpdated":"2024-08-05T16:19:29.263Z","orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE"},"references":[{"name":"1038546","tags":["vdb-entry","x_refsource_SECTRACK","x_transferred"],"url":"http://www.securitytracker.com/id/1038546"},{"tags":["x_refsource_MISC","x_transferred"],"url":"https://ics-cert.us-cert.gov/advisories/ICSA-17-115-04"}],"title":"CVE Program Container"},{"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":9.8,"baseSeverity":"CRITICAL","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"}},{"other":{"content":{"id":"CVE-2017-7898","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"total"}],"role":"CISA Coordinator","timestamp":"2026-06-03T13:20:17.293957Z","version":"2.0.3"},"type":"ssvc"}}],"providerMetadata":{"dateUpdated":"2026-06-03T13:20:28.427Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"product":"Rockwell Automation Allen-Bradley MicroLogix 1100 and 1400","vendor":"n/a","versions":[{"status":"affected","version":"Rockwell Automation Allen-Bradley MicroLogix 1100 and 1400"}]}],"datePublic":"2017-06-29T00:00:00.000Z","descriptions":[{"lang":"en","value":"An Improper Restriction of Excessive Authentication Attempts issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. There are no penalties for repeatedly entering incorrect passwords."}],"problemTypes":[{"descriptions":[{"cweId":"CWE-307","description":"CWE-307","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2017-07-07T09:57:01.000Z","orgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","shortName":"icscert"},"references":[{"name":"1038546","tags":["vdb-entry","x_refsource_SECTRACK"],"url":"http://www.securitytracker.com/id/1038546"},{"tags":["x_refsource_MISC"],"url":"https://ics-cert.us-cert.gov/advisories/ICSA-17-115-04"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","ID":"CVE-2017-7898","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Rockwell Automation Allen-Bradley MicroLogix 1100 and 1400","version":{"version_data":[{"version_value":"Rockwell Automation Allen-Bradley MicroLogix 1100 and 1400"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"An Improper Restriction of Excessive Authentication Attempts issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. There are no penalties for repeatedly entering incorrect passwords."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-307"}]}]},"references":{"reference_data":[{"name":"1038546","refsource":"SECTRACK","url":"http://www.securitytracker.com/id/1038546"},{"name":"https://ics-cert.us-cert.gov/advisories/ICSA-17-115-04","refsource":"MISC","url":"https://ics-cert.us-cert.gov/advisories/ICSA-17-115-04"}]}}}},"cveMetadata":{"assignerOrgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","assignerShortName":"icscert","cveId":"CVE-2017-7898","datePublished":"2017-06-30T02:35:00.000Z","dateReserved":"2017-04-18T00:00:00.000Z","dateUpdated":"2026-06-03T13:20:28.427Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2017-06-30 03:29:00","lastModifiedDate":"2026-06-03 14:16:19","problem_types":["CWE-307","CWE-307 CWE-307"],"metrics":{"cvssMetricV31":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":5.9}],"cvssMetricV30":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:N/A:N","baseScore":5,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"NONE","availabilityImpact":"NONE"},"baseSeverity":"MEDIUM","exploitabilityScore":10,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:rockwellautomation:1763-l16awa_series_a:*:*:*:*:*:*:*:*","versionEndIncluding":"16.000","matchCriteriaId":"E44D0CCE-EDA7-4DF2-B67B-C59DFAE7F888"},{"vulnerable":true,"criteria":"cpe:2.3:a:rockwellautomation:1763-l16awa_series_b:*:*:*:*:*:*:*:*","versionEndIncluding":"16.000","matchCriteriaId":"58E4AB51-E136-4AA3-AFF9-50F240489856"},{"vulnerable":true,"criteria":"cpe:2.3:a:rockwellautomation:1763-l16bbb_series_a:*:*:*:*:*:*:*:*","versionEndIncluding":"16.000","matchCriteriaId":"6006CE1E-08EC-4AFC-8F35-73B24AA7F08D"},{"vulnerable":true,"criteria":"cpe:2.3:a:rockwellautomation:1763-l16bbb_series_b:*:*:*:*:*:*:*:*","versionEndIncluding":"16.000","matchCriteriaId":"F52398D3-996E-4291-887F-6B8E0AF24AFF"},{"vulnerable":true,"criteria":"cpe:2.3:a:rockwellautomation:1763-l16bwa_series_a:*:*:*:*:*:*:*:*","versionEndIncluding":"16.000","matchCriteriaId":"61603F24-7505-4A9E-BA9E-57C7B5A60A6E"},{"vulnerable":true,"criteria":"cpe:2.3:a:rockwellautomation:1763-l16bwa_series_b:*:*:*:*:*:*:*:*","versionEndIncluding":"16.000","matchCriteriaId":"9558148B-3000-4D83-9AB0-380D7FBB0C9A"},{"vulnerable":true,"criteria":"cpe:2.3:a:rockwellautomation:1763-l16dwd_series_a:*:*:*:*:*:*:*:*","versionEndIncluding":"16.000","matchCriteriaId":"C805AFD6-481C-4A32-9CE8-281F9B793263"},{"vulnerable":true,"criteria":"cpe:2.3:a:rockwellautomation:1763-l16dwd_series_b:*:*:*:*:*:*:*:*","versionEndIncluding":"16.000","matchCriteriaId":"DC9E1F42-4F17-4EA4-8D0F-30220F560A0E"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:rockwellautomation:ab_micrologix_controller:1100:*:*:*:*:*:*:*","matchCriteriaId":"FA98842B-9D09-4C37-AB34-4E9FA566BAD8"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:rockwellautomation:1766-l32awa_series_a:*:*:*:*:*:*:*:*","versionEndIncluding":"16.000","matchCriteriaId":"8C8E3AF6-1017-4A18-99CA-854F1022ED66"},{"vulnerable":true,"criteria":"cpe:2.3:a:rockwellautomation:1766-l32awa_series_b:*:*:*:*:*:*:*:*","versionEndIncluding":"16.000","matchCriteriaId":"A093AA8B-7DB9-4373-AE8F-F8B879A4BE5E"},{"vulnerable":true,"criteria":"cpe:2.3:a:rockwellautomation:1766-l32awaa_series_a:*:*:*:*:*:*:*:*","versionEndIncluding":"16.000","matchCriteriaId":"25DA9309-964B-4C1C-8B95-9C1CD80DDC74"},{"vulnerable":true,"criteria":"cpe:2.3:a:rockwellautomation:1766-l32awaa_series_b:*:*:*:*:*:*:*:*","versionEndIncluding":"16.000","matchCriteriaId":"6D51D3F6-ABB3-4FFD-81D5-B3D3C29F0A46"},{"vulnerable":true,"criteria":"cpe:2.3:a:rockwellautomation:1766-l32bwa_series_a:*:*:*:*:*:*:*:*","versionEndIncluding":"16.000","matchCriteriaId":"DC05C3A1-1042-46AD-83D8-765AF4C9BCD9"},{"vulnerable":true,"criteria":"cpe:2.3:a:rockwellautomation:1766-l32bwa_series_b:*:*:*:*:*:*:*:*","versionEndIncluding":"16.000","matchCriteriaId":"6218A006-1F60-4E29-85CC-7D1BCBD7C734"},{"vulnerable":true,"criteria":"cpe:2.3:a:rockwellautomation:1766-l32bwaa_series_a:*:*:*:*:*:*:*:*","versionEndIncluding":"16.000","matchCriteriaId":"6B863572-CECF-47DF-AF6F-C25F88200DBE"},{"vulnerable":true,"criteria":"cpe:2.3:a:rockwellautomation:1766-l32bwaa_series_b:*:*:*:*:*:*:*:*","versionEndIncluding":"16.000","matchCriteriaId":"59BEBB0E-8C6E-4663-9E0C-E755C2EF0041"},{"vulnerable":true,"criteria":"cpe:2.3:a:rockwellautomation:1766-l32bxb_series_a:*:*:*:*:*:*:*:*","versionEndIncluding":"16.000","matchCriteriaId":"1303D987-4A44-4F33-992E-0C7E683EC7A9"},{"vulnerable":true,"criteria":"cpe:2.3:a:rockwellautomation:1766-l32bxb_series_b:*:*:*:*:*:*:*:*","versionEndIncluding":"16.000","matchCriteriaId":"1E7D8E09-D97D-45FF-9AD0-A9B0A846E600"},{"vulnerable":true,"criteria":"cpe:2.3:a:rockwellautomation:1766-l32bxba_series_a:*:*:*:*:*:*:*:*","versionEndIncluding":"16.000","matchCriteriaId":"9D9C64FB-A613-4940-86E6-95431B907159"},{"vulnerable":true,"criteria":"cpe:2.3:a:rockwellautomation:1766-l32bxba_series_b:*:*:*:*:*:*:*:*","versionEndIncluding":"16.000","matchCriteriaId":"B5C50D4A-EB32-4BE4-B9E6-D25494E2EF55"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:rockwellautomation:ab_micrologix_controller:1400:*:*:*:*:*:*:*","matchCriteriaId":"FFF2EF59-F451-490D-A7AF-E66D11493948"}]}]}]},"legacy_mitre":{"record":{"CveYear":"2017","CveId":"7898","Ordinal":"1","Title":"CVE-2017-7898","CVE":"CVE-2017-7898","Year":"2017"},"notes":[{"CveYear":"2017","CveId":"7898","Ordinal":"1","NoteData":"An Improper Restriction of Excessive Authentication Attempts issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. There are no penalties for repeatedly entering incorrect passwords.","Type":"Description","Title":"CVE-2017-7898"},{"CveYear":"2017","CveId":"7898","Ordinal":"2","NoteData":"2017-06-29","Type":"Other","Title":"Published"},{"CveYear":"2017","CveId":"7898","Ordinal":"3","NoteData":"2017-07-07","Type":"Other","Title":"Modified"}]}}}