{"api_version":"1","generated_at":"2026-07-23T02:54:54+00:00","cve":"CVE-2017-7972","urls":{"html":"https://cve.report/CVE-2017-7972","api":"https://cve.report/api/cve/CVE-2017-7972.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2017-7972","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2017-7972"},"summary":{"title":"CVE-2017-7972","description":"A vulnerability exists in Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 that allows the ability to escape out of remote PowerSCADA Anywhere applications and launch other processes.","state":"PUBLIC","assigner":"cybersecurity@schneider-electric.com","published_at":"2017-09-26 01:29:00","updated_at":"2019-10-03 00:03:00"},"problem_types":["NVD-CWE-noinfo"],"metrics":[],"references":[{"url":"http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/","name":"http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/","refsource":"CONFIRM","tags":["Mitigation","Patch","Vendor Advisory"],"title":"Security Notification - PowerSCADA  | Download Schneider Electric","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9071-security-notification-citect-anywhere","name":"https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9071-security-notification-citect-anywhere","refsource":"CONFIRM","tags":["Issue Tracking","Mitigation","Patch","Vendor Advisory"],"title":"AVEVA Global Customer Support - Login","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"http://www.securityfocus.com/bid/99913","name":"99913","refsource":"BID","tags":["Third Party Advisory","VDB Entry"],"title":"Schneider Electric PowerSCADA Anywhere and Citect Anywhere Multiple Security Vulnerabilities","mime":"text/html","httpstatus":"200","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2017-7972","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2017-7972","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2017","cve_id":"7972","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"citect_anywhere","cpe6":"1.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"7972","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"citect_anywhere","cpe6":"1.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"7972","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"powerscada_anywhere","cpe6":"1.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"7972","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"powerscada_anywhere","cpe6":"1.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"7972","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"powerscada_expert","cpe6":"8.1","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"7972","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"powerscada_expert","cpe6":"8.2","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"7972","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"powerscada_expert","cpe6":"8.1","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"7972","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"powerscada_expert","cpe6":"8.2","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"cybersecurity@schneider-electric.com","DATE_PUBLIC":"2017-06-22T00:00:00","ID":"CVE-2017-7972","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"PowerSCADA Anywhere","version":{"version_data":[{"version_value":"Version 1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2"}]}},{"product_name":"Citect Anywhere","version":{"version_data":[{"version_value":"version 1.0"}]}}]},"vendor_name":"Schneider Electric SE"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"A vulnerability exists in Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 that allows the ability to escape out of remote PowerSCADA Anywhere applications and launch other processes."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"Escaping PowerSCADA Application"}]}]},"references":{"reference_data":[{"name":"99913","refsource":"BID","url":"http://www.securityfocus.com/bid/99913"},{"name":"https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9071-security-notification-citect-anywhere","refsource":"CONFIRM","url":"https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9071-security-notification-citect-anywhere"},{"name":"http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/","refsource":"CONFIRM","url":"http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/"}]}},"nvd":{"publishedDate":"2017-09-26 01:29:00","lastModifiedDate":"2019-10-03 00:03:00","problem_types":["NVD-CWE-noinfo"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.0","vectorString":"CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L","attackVector":"ADJACENT_NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"LOW","baseScore":5.5,"baseSeverity":"MEDIUM"},"exploitabilityScore":2.1,"impactScore":3.4},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:A/AC:L/Au:S/C:P/I:P/A:P","accessVector":"ADJACENT_NETWORK","accessComplexity":"LOW","authentication":"SINGLE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL","baseScore":5.2},"severity":"MEDIUM","exploitabilityScore":5.1,"impactScore":6.4,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:schneider-electric:powerscada_anywhere:1.0:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:a:schneider-electric:powerscada_expert:8.1:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":false,"cpe23Uri":"cpe:2.3:a:schneider-electric:powerscada_expert:8.2:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:schneider-electric:citect_anywhere:1.0:*:*:*:*:*:*:*","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2017","CveId":"7972","Ordinal":"104855","Title":"CVE-2017-7972","CVE":"CVE-2017-7972","Year":"2017"},"notes":[{"CveYear":"2017","CveId":"7972","Ordinal":"1","NoteData":"A vulnerability exists in Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 that allows the ability to escape out of remote PowerSCADA Anywhere applications and launch other processes.","Type":"Description","Title":null},{"CveYear":"2017","CveId":"7972","Ordinal":"2","NoteData":"2017-09-25","Type":"Other","Title":"Published"},{"CveYear":"2017","CveId":"7972","Ordinal":"3","NoteData":"2017-09-26","Type":"Other","Title":"Modified"}]}}}