{"api_version":"1","generated_at":"2026-04-23T11:30:09+00:00","cve":"CVE-2017-8414","urls":{"html":"https://cve.report/CVE-2017-8414","api":"https://cve.report/api/cve/CVE-2017-8414.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2017-8414","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2017-8414"},"summary":{"title":"CVE-2017-8414","description":"An issue was discovered on D-Link DCS-1100 and DCS-1130 devices. The binary orthrus in /sbin folder of the device handles all the UPnP connections received by the device. It seems that the binary performs a sprintf operation at address 0x0000A3E4 with the value in the command line parameter \"-f\" and stores it on the stack. Since there is no length check, this results in corrupting the registers for the function sub_A098 which results in memory corruption.","state":"PUBLIC","assigner":"cve@mitre.org","published_at":"2019-07-02 20:15:00","updated_at":"2021-04-23 18:47:00"},"problem_types":["CWE-119"],"metrics":[],"references":[{"url":"https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Dlink_DCS_1130_security.pdf","name":"https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Dlink_DCS_1130_security.pdf","refsource":"MISC","tags":["Exploit","Third Party Advisory"],"title":"IoT_vulnerabilities/Dlink_DCS_1130_security.pdf at master · ethanhunnt/IoT_vulnerabilities · GitHub","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"http://packetstormsecurity.com/files/153226/Dlink-DCS-1130-Command-Injection-CSRF-Stack-Overflow.html","name":"http://packetstormsecurity.com/files/153226/Dlink-DCS-1130-Command-Injection-CSRF-Stack-Overflow.html","refsource":"MISC","tags":["Third Party Advisory","VDB Entry"],"title":"Dlink DCS-1130 Command Injection / CSRF / Stack Overflow ≈ Packet Storm","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://seclists.org/bugtraq/2019/Jun/8","name":"20190609 Newly releases IoT security issues","refsource":"BUGTRAQ","tags":["Mailing List","Third Party Advisory"],"title":"Bugtraq: Newly releases IoT security issues","mime":"text/html","httpstatus":"200","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2017-8414","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2017-8414","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2017","cve_id":"8414","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"d-link","cpe5":"dcs-1100","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"8414","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"d-link","cpe5":"dcs-1100_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"8414","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"d-link","cpe5":"dcs-1130","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"8414","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"d-link","cpe5":"dcs-1130_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"8414","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"dlink","cpe5":"dcs-1100","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"8414","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"dlink","cpe5":"dcs-1100","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"8414","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"dlink","cpe5":"dcs-1100_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"8414","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"dlink","cpe5":"dcs-1100_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"8414","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"dlink","cpe5":"dcs-1130","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"8414","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"dlink","cpe5":"dcs-1130","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"8414","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"dlink","cpe5":"dcs-1130_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2017","cve_id":"8414","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"dlink","cpe5":"dcs-1130_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"cve@mitre.org","ID":"CVE-2017-8414","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"n/a","version":{"version_data":[{"version_value":"n/a"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"An issue was discovered on D-Link DCS-1100 and DCS-1130 devices. The binary orthrus in /sbin folder of the device handles all the UPnP connections received by the device. It seems that the binary performs a sprintf operation at address 0x0000A3E4 with the value in the command line parameter \"-f\" and stores it on the stack. Since there is no length check, this results in corrupting the registers for the function sub_A098 which results in memory corruption."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"n/a"}]}]},"references":{"reference_data":[{"refsource":"BUGTRAQ","name":"20190609 Newly releases IoT security issues","url":"https://seclists.org/bugtraq/2019/Jun/8"},{"refsource":"MISC","name":"http://packetstormsecurity.com/files/153226/Dlink-DCS-1130-Command-Injection-CSRF-Stack-Overflow.html","url":"http://packetstormsecurity.com/files/153226/Dlink-DCS-1130-Command-Injection-CSRF-Stack-Overflow.html"},{"refsource":"MISC","name":"https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Dlink_DCS_1130_security.pdf","url":"https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Dlink_DCS_1130_security.pdf"}]}},"nvd":{"publishedDate":"2019-07-02 20:15:00","lastModifiedDate":"2021-04-23 18:47:00","problem_types":["CWE-119"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:L/AC:L/Au:N/C:C/I:C/A:C","accessVector":"LOCAL","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE","baseScore":7.2},"severity":"HIGH","exploitabilityScore":3.9,"impactScore":10,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:dlink:dcs-1100_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:dlink:dcs-1100:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:dlink:dcs-1130_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:dlink:dcs-1130:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":{"CveYear":"2017","CveId":"8414","Ordinal":"105312","Title":"CVE-2017-8414","CVE":"CVE-2017-8414","Year":"2017"},"notes":[{"CveYear":"2017","CveId":"8414","Ordinal":"1","NoteData":"An issue was discovered on D-Link DCS-1100 and DCS-1130 devices. The binary orthrus in /sbin folder of the device handles all the UPnP connections received by the device. It seems that the binary performs a sprintf operation at address 0x0000A3E4 with the value in the command line parameter \"-f\" and stores it on the stack. Since there is no length check, this results in corrupting the registers for the function sub_A098 which results in memory corruption.","Type":"Description","Title":null},{"CveYear":"2017","CveId":"8414","Ordinal":"2","NoteData":"2019-07-02","Type":"Other","Title":"Published"},{"CveYear":"2017","CveId":"8414","Ordinal":"3","NoteData":"2019-07-02","Type":"Other","Title":"Modified"}]}}}