{"api_version":"1","generated_at":"2026-07-23T18:58:04+00:00","cve":"CVE-2017-9939","urls":{"html":"https://cve.report/CVE-2017-9939","api":"https://cve.report/api/cve/CVE-2017-9939.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2017-9939","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2017-9939"},"summary":{"title":"CVE-2017-9939","description":"A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker with network access to the SiPass integrated server to bypass the authentication mechanism and perform administrative operations.","state":"PUBLIC","assigner":"productcert@siemens.com","published_at":"2017-08-08 00:29:00","updated_at":"2019-10-09 23:30:00"},"problem_types":["CWE-287"],"metrics":[],"references":[{"url":"http://www.securityfocus.com/bid/99578","name":"99578","refsource":"BID","tags":["Third Party Advisory","VDB Entry"],"title":"Malformed Request","mime":"text/html","httpstatus":"200","archivestatus":"0"},{"url":"https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-339433.pdf","name":"https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-339433.pdf","refsource":"CONFIRM","tags":["Vendor Advisory"],"title":"Siemens","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"https://www.cve.org/CVERecord?id=CVE-2017-9939","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2017-9939","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2017","cve_id":"9939","vulnerable":"1","versionEndIncluding":"2.65","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"sipass_integrated","cpe6":"*","cpe7":"sp2","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"productcert@siemens.com","ID":"CVE-2017-9939","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"SiPass integrated All versions before V2.70","version":{"version_data":[{"version_value":"SiPass integrated All versions before V2.70"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker with network access to the SiPass integrated server to bypass the authentication mechanism and perform administrative operations."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-287: Improper Authentication"}]}]},"references":{"reference_data":[{"name":"https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-339433.pdf","refsource":"CONFIRM","url":"https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-339433.pdf"},{"name":"99578","refsource":"BID","url":"http://www.securityfocus.com/bid/99578"}]}},"nvd":{"publishedDate":"2017-08-08 00:29:00","lastModifiedDate":"2019-10-09 23:30:00","problem_types":["CWE-287"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":9.8,"baseSeverity":"CRITICAL"},"exploitabilityScore":3.9,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:P/A:P","accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL","baseScore":7.5},"severity":"HIGH","exploitabilityScore":10,"impactScore":6.4,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:sipass_integrated:*:sp2:*:*:*:*:*:*","versionEndIncluding":"2.65","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2017","CveId":"9939","Ordinal":"107579","Title":"CVE-2017-9939","CVE":"CVE-2017-9939","Year":"2017"},"notes":[{"CveYear":"2017","CveId":"9939","Ordinal":"1","NoteData":"A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker with network access to the SiPass integrated server to bypass the authentication mechanism and perform administrative operations.","Type":"Description","Title":null},{"CveYear":"2017","CveId":"9939","Ordinal":"2","NoteData":"2017-08-07","Type":"Other","Title":"Published"},{"CveYear":"2017","CveId":"9939","Ordinal":"3","NoteData":"2017-08-08","Type":"Other","Title":"Modified"}]}}}