{"api_version":"1","generated_at":"2026-07-23T04:59:01+00:00","cve":"CVE-2017-9967","urls":{"html":"https://cve.report/CVE-2017-9967","api":"https://cve.report/api/cve/CVE-2017-9967.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2017-9967","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2017-9967"},"summary":{"title":"CVE-2017-9967","description":"A security misconfiguration vulnerability exists in Schneider Electric's IGSS SCADA Software versions 12 and prior. Security configuration settings such as Address Space Layout Randomization (ASLR) and Data Execution prevention (DEP) were not properly configured resulting in weak security.","state":"PUBLIC","assigner":"cybersecurity@schneider-electric.com","published_at":"2018-02-12 23:29:00","updated_at":"2019-10-03 00:03:00"},"problem_types":["NVD-CWE-noinfo"],"metrics":[],"references":[{"url":"http://www.securityfocus.com/bid/103022","name":"103022","refsource":"BID","tags":["Third Party Advisory","VDB Entry"],"title":"Malformed Request","mime":"text/html","httpstatus":"200","archivestatus":"0"},{"url":"https://www.schneider-electric.com/en/download/document/SEVD-2018-037-01/","name":"https://www.schneider-electric.com/en/download/document/SEVD-2018-037-01/","refsource":"CONFIRM","tags":["Vendor Advisory"],"title":"Security Notification- IGSS SCADA Software | Schneider Electric","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2017-9967","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2017-9967","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2017","cve_id":"9967","vulnerable":"1","versionEndIncluding":"12.0","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"interactive_graphical_scada_system","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"cybersecurity@schneider-electric.com","DATE_PUBLIC":"2018-02-12T00:00:00","ID":"CVE-2017-9967","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"n/a","version":{"version_data":[{"version_value":"n/a"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"A security misconfiguration vulnerability exists in Schneider Electric's IGSS SCADA Software versions 12 and prior. Security configuration settings such as Address Space Layout Randomization (ASLR) and Data Execution prevention (DEP) were not properly configured resulting in weak security."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"n/a"}]}]},"references":{"reference_data":[{"name":"https://www.schneider-electric.com/en/download/document/SEVD-2018-037-01/","refsource":"CONFIRM","url":"https://www.schneider-electric.com/en/download/document/SEVD-2018-037-01/"},{"name":"103022","refsource":"BID","url":"http://www.securityfocus.com/bid/103022"}]}},"nvd":{"publishedDate":"2018-02-12 23:29:00","lastModifiedDate":"2019-10-03 00:03:00","problem_types":["NVD-CWE-noinfo"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.0","vectorString":"CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:L/AC:L/Au:N/C:P/I:P/A:P","accessVector":"LOCAL","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL","baseScore":4.6},"severity":"MEDIUM","exploitabilityScore":3.9,"impactScore":6.4,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:schneider-electric:interactive_graphical_scada_system:*:*:*:*:*:*:*:*","versionEndIncluding":"12.0","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2017","CveId":"9967","Ordinal":"107607","Title":"CVE-2017-9967","CVE":"CVE-2017-9967","Year":"2017"},"notes":[{"CveYear":"2017","CveId":"9967","Ordinal":"1","NoteData":"A security misconfiguration vulnerability exists in Schneider Electric's IGSS SCADA Software versions 12 and prior. Security configuration settings such as Address Space Layout Randomization (ASLR) and Data Execution prevention (DEP) were not properly configured resulting in weak security.","Type":"Description","Title":null},{"CveYear":"2017","CveId":"9967","Ordinal":"2","NoteData":"2018-02-12","Type":"Other","Title":"Published"},{"CveYear":"2017","CveId":"9967","Ordinal":"3","NoteData":"2018-02-15","Type":"Other","Title":"Modified"}]}}}