{"api_version":"1","generated_at":"2026-04-23T22:08:23+00:00","cve":"CVE-2018-10619","urls":{"html":"https://cve.report/CVE-2018-10619","api":"https://cve.report/api/cve/CVE-2018-10619.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2018-10619","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2018-10619"},"summary":{"title":"CVE-2018-10619","description":"An unquoted search path or element in RSLinx Classic Versions 3.90.01 and prior and FactoryTalk Linx Gateway Versions 3.90.00 and prior may allow an authorized, but non-privileged local user to execute arbitrary code and allow a threat actor to escalate user privileges on the affected workstation.","state":"PUBLIC","assigner":"ics-cert@hq.dhs.gov","published_at":"2018-06-07 20:29:00","updated_at":"2019-10-09 23:32:00"},"problem_types":["CWE-428"],"metrics":[],"references":[{"url":"http://www.securityfocus.com/bid/104415","name":"104415","refsource":"BID","tags":["Third Party Advisory","VDB Entry"],"title":"Multiplle Rockwell Automation Products CVE-2018-10619 Local Privilege Escalation Vulnerability","mime":"text/html","httpstatus":"200","archivestatus":"0"},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-18-158-01","name":"https://ics-cert.us-cert.gov/advisories/ICSA-18-158-01","refsource":"MISC","tags":["Third Party Advisory","US Government Resource","VDB Entry"],"title":"Rockwell Automation RSLinx Classic and FactoryTalk Linx Gateway | ICS-CERT","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.exploit-db.com/exploits/44892/","name":"44892","refsource":"EXPLOIT-DB","tags":["Exploit","Third Party Advisory","VDB Entry"],"title":"RSLinx Classic and FactoryTalk Linx Gateway - Privilege Escalation - Windows local Exploit","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2018-10619","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2018-10619","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2018","cve_id":"10619","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"rockwellautomation","cpe5":"factorytalk_linx_gateway","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2018","cve_id":"10619","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"rockwellautomation","cpe5":"factorytalk_linx_gateway","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2018","cve_id":"10619","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"rockwellautomation","cpe5":"rslinx_classic","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2018","cve_id":"10619","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"rockwellautomation","cpe5":"rslinx_classic","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","DATE_PUBLIC":"2018-06-07T00:00:00","ID":"CVE-2018-10619","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Rockwell Automation RSLinx Classic and FactoryTalk Linx Gateway","version":{"version_data":[{"version_value":"RSLinx Classic Versions 3.90.01 and prior, FactoryTalk Linx Gateway Versions 3.90.00 and prior."}]}}]},"vendor_name":"ICS-CERT"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"An unquoted search path or element in RSLinx Classic Versions 3.90.01 and prior and FactoryTalk Linx Gateway Versions 3.90.00 and prior may allow an authorized, but non-privileged local user to execute arbitrary code and allow a threat actor to escalate user privileges on the affected workstation."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"UNQUOTED SEARCH PATH OR ELEMENT CWE-428"}]}]},"references":{"reference_data":[{"name":"44892","refsource":"EXPLOIT-DB","url":"https://www.exploit-db.com/exploits/44892/"},{"name":"https://ics-cert.us-cert.gov/advisories/ICSA-18-158-01","refsource":"MISC","url":"https://ics-cert.us-cert.gov/advisories/ICSA-18-158-01"},{"name":"104415","refsource":"BID","url":"http://www.securityfocus.com/bid/104415"}]}},"nvd":{"publishedDate":"2018-06-07 20:29:00","lastModifiedDate":"2019-10-09 23:32:00","problem_types":["CWE-428"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.0","vectorString":"CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:L/AC:L/Au:N/C:P/I:P/A:P","accessVector":"LOCAL","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL","baseScore":4.6},"severity":"MEDIUM","exploitabilityScore":3.9,"impactScore":6.4,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:rockwellautomation:rslinx_classic:*:*:*:*:*:*:*:*","versionEndExcluding":"3.90.01","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:rockwellautomation:factorytalk_linx_gateway:*:*:*:*:*:*:*:*","versionEndExcluding":"3.90.00","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2018","CveId":"10619","Ordinal":"127060","Title":"CVE-2018-10619","CVE":"CVE-2018-10619","Year":"2018"},"notes":[{"CveYear":"2018","CveId":"10619","Ordinal":"1","NoteData":"An unquoted search path or element in RSLinx Classic Versions 3.90.01 and prior and FactoryTalk Linx Gateway Versions 3.90.00 and prior may allow an authorized, but non-privileged local user to execute arbitrary code and allow a threat actor to escalate user privileges on the affected workstation.","Type":"Description","Title":null},{"CveYear":"2018","CveId":"10619","Ordinal":"2","NoteData":"2018-06-07","Type":"Other","Title":"Published"},{"CveYear":"2018","CveId":"10619","Ordinal":"3","NoteData":"2018-06-15","Type":"Other","Title":"Modified"}]}}}