{"api_version":"1","generated_at":"2026-07-23T22:21:51+00:00","cve":"CVE-2018-14558","urls":{"html":"https://cve.report/CVE-2018-14558","api":"https://cve.report/api/cve/CVE-2018-14558.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2018-14558","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2018-14558"},"summary":{"title":"CVE-2018-14558","description":"An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A command Injection vulnerability allows attackers to execute arbitrary OS commands via a crafted goform/setUsbUnload request. This occurs because the \"formsetUsbUnload\" function executes a dosystemCmd function with untrusted input.","state":"PUBLIC","assigner":"cve@mitre.org","published_at":"2018-10-30 18:29:00","updated_at":"2019-10-03 00:03:00"},"problem_types":["CWE-78"],"metrics":[],"references":[{"url":"https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-01/Tenda.md","name":"https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-01/Tenda.md","refsource":"MISC","tags":["Exploit","Third Party Advisory"],"title":"iot/Tenda.md at master · zsjevilhex/iot · GitHub","mime":"text/html","httpstatus":"200","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2018-14558","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2018-14558","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2018","cve_id":"14558","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"tenda","cpe5":"ac10","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2018","cve_id":"14558","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"tenda","cpe5":"ac10","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2018","cve_id":"14558","vulnerable":"1","versionEndIncluding":"15.03.06.23_cn","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"tenda","cpe5":"ac10_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2018","cve_id":"14558","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"tenda","cpe5":"ac7","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2018","cve_id":"14558","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"tenda","cpe5":"ac7","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2018","cve_id":"14558","vulnerable":"1","versionEndIncluding":"15.03.06.44_cn","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"tenda","cpe5":"ac7_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2018","cve_id":"14558","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"tenda","cpe5":"ac9","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2018","cve_id":"14558","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"tenda","cpe5":"ac9","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2018","cve_id":"14558","vulnerable":"1","versionEndIncluding":"15.03.05.19(6318)_cn","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"tenda","cpe5":"ac9_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2018","cve_id":"14558","vulnerable":"1","versionEndIncluding":"15.03.05.19\\(6318\\)_cn","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"tenda","cpe5":"ac9_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":{"cve_year":"2018","cve_id":"14558","cve":"CVE-2018-14558","vendorProject":"Tenda","product":"AC7, AC9, and AC10 Routers","vulnerabilityName":"Tenda AC7, AC9, and AC10 Routers Command Injection Vulnerability","dateAdded":"2021-11-03","shortDescription":"Tenda AC7, AC9, and AC10 devices contain a command injection vulnerability due to  the \"formsetUsbUnload\" function executes a dosystemCmd function with untrusted input. Successful exploitation allows an attacker to execute OS commands via a crafted goform/setUsbUnload request.","requiredAction":"Apply updates per vendor instructions.","dueDate":"2022-05-03","knownRansomwareCampaignUse":"Unknown","notes":"https://nvd.nist.gov/vuln/detail/CVE-2018-14558","cwes":"CWE-78","catalogVersion":"2026.07.23","updated_at":"2026-07-23 17:19:19"},"epss":{"cve_year":"2018","cve_id":"14558","cve":"CVE-2018-14558","epss":"0.086720000","percentile":"0.945600000","score_date":"2026-07-22","updated_at":"2026-07-23 00:09:34"},"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"cve@mitre.org","ID":"CVE-2018-14558","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"n/a","version":{"version_data":[{"version_value":"n/a"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A command Injection vulnerability allows attackers to execute arbitrary OS commands via a crafted goform/setUsbUnload request. This occurs because the \"formsetUsbUnload\" function executes a dosystemCmd function with untrusted input."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"n/a"}]}]},"references":{"reference_data":[{"name":"https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-01/Tenda.md","refsource":"MISC","url":"https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-01/Tenda.md"}]}},"nvd":{"publishedDate":"2018-10-30 18:29:00","lastModifiedDate":"2019-10-03 00:03:00","problem_types":["CWE-78"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":9.8,"baseSeverity":"CRITICAL"},"exploitabilityScore":3.9,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:C/I:C/A:C","accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE","baseScore":10},"severity":"HIGH","exploitabilityScore":10,"impactScore":10,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:tenda:ac7_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"15.03.06.44_cn","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"15.03.05.19\\(6318\\)_cn","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:tenda:ac10_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"15.03.06.23_cn","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":{"CveYear":"2018","CveId":"14558","Ordinal":"131229","Title":"CVE-2018-14558","CVE":"CVE-2018-14558","Year":"2018"},"notes":[{"CveYear":"2018","CveId":"14558","Ordinal":"1","NoteData":"An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A command Injection vulnerability allows attackers to execute arbitrary OS commands via a crafted goform/setUsbUnload request. This occurs because the \"formsetUsbUnload\" function executes a dosystemCmd function with untrusted input.","Type":"Description","Title":null},{"CveYear":"2018","CveId":"14558","Ordinal":"2","NoteData":"2018-10-30","Type":"Other","Title":"Published"},{"CveYear":"2018","CveId":"14558","Ordinal":"3","NoteData":"2018-10-30","Type":"Other","Title":"Modified"}]}}}