{"api_version":"1","generated_at":"2026-05-12T10:32:25+00:00","cve":"CVE-2018-17897","urls":{"html":"https://cve.report/CVE-2018-17897","api":"https://cve.report/api/cve/CVE-2018-17897.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2018-17897","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2018-17897"},"summary":{"title":"CVE-2018-17897","description":"LAquis SCADA Versions 4.1.0.3870 and prior has several integer overflow to buffer overflow vulnerabilities, which may allow remote code execution.","state":"PUBLIC","assigner":"ics-cert@hq.dhs.gov","published_at":"2018-10-17 02:29:00","updated_at":"2018-11-30 15:26:00"},"problem_types":["CWE-190"],"metrics":[],"references":[{"url":"http://www.securityfocus.com/bid/105719","name":"105719","refsource":"BID","tags":["Third Party Advisory","VDB Entry"],"title":"Malformed Request","mime":"text/html","httpstatus":"200","archivestatus":"0"},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-18-289-01","name":"https://ics-cert.us-cert.gov/advisories/ICSA-18-289-01","refsource":"MISC","tags":["Third Party Advisory","US Government Resource"],"title":"LCDS – Leão Consultoria e Desenvolvimento de Sistemas Ltda ME LAquis SCADA | ICS-CERT","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"http://laquisscada.com/instale1.php","name":"http://laquisscada.com/instale1.php","refsource":"MISC","tags":["Product","Vendor Advisory"],"title":"Install LAquis SCADA software","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2018-17897","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2018-17897","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2018","cve_id":"17897","vulnerable":"1","versionEndIncluding":"4.1.0.3870","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"lcds","cpe5":"laquis_scada","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[{"cve":"CVE-2018-17897","qid":"590866","title":"LCDS LAquis SCADA Multiple Vulnerabilities (ICSA-18-289-01)"}]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","ID":"CVE-2018-17897","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"n/a","version":{"version_data":[{"version_value":"n/a"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"LAquis SCADA Versions 4.1.0.3870 and prior has several integer overflow to buffer overflow vulnerabilities, which may allow remote code execution."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"n/a"}]}]},"references":{"reference_data":[{"name":"http://laquisscada.com/instale1.php","refsource":"MISC","url":"http://laquisscada.com/instale1.php"},{"name":"105719","refsource":"BID","url":"http://www.securityfocus.com/bid/105719"},{"name":"https://ics-cert.us-cert.gov/advisories/ICSA-18-289-01","refsource":"MISC","url":"https://ics-cert.us-cert.gov/advisories/ICSA-18-289-01"}]}},"nvd":{"publishedDate":"2018-10-17 02:29:00","lastModifiedDate":"2018-11-30 15:26:00","problem_types":["CWE-190"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":9.8,"baseSeverity":"CRITICAL"},"exploitabilityScore":3.9,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:P/A:P","accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL","baseScore":7.5},"severity":"HIGH","exploitabilityScore":10,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:lcds:laquis_scada:*:*:*:*:*:*:*:*","versionEndIncluding":"4.1.0.3870","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2018","CveId":"17897","Ordinal":"134714","Title":"CVE-2018-17897","CVE":"CVE-2018-17897","Year":"2018"},"notes":[{"CveYear":"2018","CveId":"17897","Ordinal":"1","NoteData":"LAquis SCADA Versions 4.1.0.3870 and prior has several integer overflow to buffer overflow vulnerabilities, which may allow remote code execution.","Type":"Description","Title":null},{"CveYear":"2018","CveId":"17897","Ordinal":"2","NoteData":"2018-10-16","Type":"Other","Title":"Published"},{"CveYear":"2018","CveId":"17897","Ordinal":"3","NoteData":"2018-10-25","Type":"Other","Title":"Modified"}]}}}