{"api_version":"1","generated_at":"2026-05-12T09:35:47+00:00","cve":"CVE-2018-19029","urls":{"html":"https://cve.report/CVE-2018-19029","api":"https://cve.report/api/cve/CVE-2018-19029.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2018-19029","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2018-19029"},"summary":{"title":"CVE-2018-19029","description":"LCDS Laquis SCADA prior to version 4.1.0.4150 allows an attacker using a specially crafted project file to supply a pointer for a controlled memory address, which may allow remote code execution, data exfiltration, or cause a system crash.","state":"PUBLIC","assigner":"ics-cert@hq.dhs.gov","published_at":"2019-02-05 18:29:00","updated_at":"2019-10-09 23:37:00"},"problem_types":["CWE-476"],"metrics":[],"references":[{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01","name":"https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01","refsource":"MISC","tags":["Third Party Advisory","US Government Resource"],"title":"LCDS - Leão Consultoria e Desenvolvimento de Sistemas Ltda ME LAquis SCADA | CISA","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"http://www.securityfocus.com/bid/106634","name":"106634","refsource":"BID","tags":["Third Party Advisory","VDB Entry"],"title":"LCDS LAquis SCADA Multiple Security Vulnerabilities","mime":"text/html","httpstatus":"200","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2018-19029","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2018-19029","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2018","cve_id":"19029","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"lcds","cpe5":"laquis_scada","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2018","cve_id":"19029","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"lcds","cpe5":"laquis_scada","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","DATE_PUBLIC":"2019-01-15T00:00:00","ID":"CVE-2018-19029","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"LCDS Laquis SCADA","version":{"version_data":[{"version_value":"All versions prior to version 4.1.0.4150"}]}}]},"vendor_name":"LCDS"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"LCDS Laquis SCADA prior to version 4.1.0.4150 allows an attacker using a specially crafted project file to supply a pointer for a controlled memory address, which may allow remote code execution, data exfiltration, or cause a system crash."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"UNTRUSTED POINTER DEREFERENCE CWE-822"}]}]},"references":{"reference_data":[{"name":"https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01","refsource":"MISC","url":"https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01"},{"name":"106634","refsource":"BID","url":"http://www.securityfocus.com/bid/106634"}]}},"nvd":{"publishedDate":"2019-02-05 18:29:00","lastModifiedDate":"2019-10-09 23:37:00","problem_types":["CWE-476"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.0","vectorString":"CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:P/I:P/A:C","accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"COMPLETE","baseScore":8.3},"severity":"HIGH","exploitabilityScore":8.6,"impactScore":8.5,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:lcds:laquis_scada:*:*:*:*:*:*:*:*","versionEndExcluding":"4.1.0.4150","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2018","CveId":"19029","Ordinal":"135955","Title":"CVE-2018-19029","CVE":"CVE-2018-19029","Year":"2018"},"notes":[{"CveYear":"2018","CveId":"19029","Ordinal":"1","NoteData":"LCDS Laquis SCADA prior to version 4.1.0.4150 allows an attacker using a specially crafted project file to supply a pointer for a controlled memory address, which may allow remote code execution, data exfiltration, or cause a system crash.","Type":"Description","Title":null},{"CveYear":"2018","CveId":"19029","Ordinal":"2","NoteData":"2019-02-05","Type":"Other","Title":"Published"},{"CveYear":"2018","CveId":"19029","Ordinal":"3","NoteData":"2019-02-06","Type":"Other","Title":"Modified"}]}}}