{"api_version":"1","generated_at":"2026-07-23T01:54:12+00:00","cve":"CVE-2018-3602","urls":{"html":"https://cve.report/CVE-2018-3602","api":"https://cve.report/api/cve/CVE-2018-3602.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2018-3602","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2018-3602"},"summary":{"title":"CVE-2018-3602","description":"An AdHocQuery_Processor SQL injection remote code execution (RCE) vulnerability in Trend Micro Control Manager 6.0 could allow a remote attacker to execute arbitrary code on vulnerable installations.","state":"PUBLIC","assigner":"security@trendmicro.com","published_at":"2018-02-09 22:29:00","updated_at":"2018-02-27 19:28:00"},"problem_types":["CWE-89"],"metrics":[],"references":[{"url":"https://success.trendmicro.com/solution/1119158","name":"https://success.trendmicro.com/solution/1119158","refsource":"CONFIRM","tags":["Patch","Vendor Advisory"],"title":"New build to resolve multiple vulnerabilities - Control Manager","mime":"text/html","httpstatus":"200","archivestatus":"0"},{"url":"https://www.zerodayinitiative.com/advisories/ZDI-18-068/","name":"https://www.zerodayinitiative.com/advisories/ZDI-18-068/","refsource":"MISC","tags":["Third Party Advisory","VDB Entry"],"title":"ZDI-18-068 | Zero Day Initiative","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2018-3602","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2018-3602","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2018","cve_id":"3602","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trendmicro","cpe5":"control_manager","cpe6":"6.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2018","cve_id":"3602","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trendmicro","cpe5":"control_manager","cpe6":"6.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"security@trendmicro.com","ID":"CVE-2018-3602","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Trend Micro Control Manager","version":{"version_data":[{"version_value":"6.0"}]}}]},"vendor_name":"Trend Micro"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"An AdHocQuery_Processor SQL injection remote code execution (RCE) vulnerability in Trend Micro Control Manager 6.0 could allow a remote attacker to execute arbitrary code on vulnerable installations."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"SQL Injection"}]}]},"references":{"reference_data":[{"name":"https://success.trendmicro.com/solution/1119158","refsource":"CONFIRM","url":"https://success.trendmicro.com/solution/1119158"},{"name":"https://www.zerodayinitiative.com/advisories/ZDI-18-068/","refsource":"MISC","url":"https://www.zerodayinitiative.com/advisories/ZDI-18-068/"}]}},"nvd":{"publishedDate":"2018-02-09 22:29:00","lastModifiedDate":"2018-02-27 19:28:00","problem_types":["CWE-89"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":8.8,"baseSeverity":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:L/Au:S/C:P/I:P/A:P","accessVector":"NETWORK","accessComplexity":"LOW","authentication":"SINGLE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL","baseScore":6.5},"severity":"MEDIUM","exploitabilityScore":8,"impactScore":6.4,"acInsufInfo":true,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:trendmicro:control_manager:6.0:*:*:*:*:*:*:*","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2018","CveId":"3602","Ordinal":"119395","Title":"CVE-2018-3602","CVE":"CVE-2018-3602","Year":"2018"},"notes":[{"CveYear":"2018","CveId":"3602","Ordinal":"1","NoteData":"An AdHocQuery_Processor SQL injection remote code execution (RCE) vulnerability in Trend Micro Control Manager 6.0 could allow a remote attacker to execute arbitrary code on vulnerable installations.","Type":"Description","Title":null},{"CveYear":"2018","CveId":"3602","Ordinal":"2","NoteData":"2018-02-09","Type":"Other","Title":"Published"},{"CveYear":"2018","CveId":"3602","Ordinal":"3","NoteData":"2018-02-09","Type":"Other","Title":"Modified"}]}}}