{"api_version":"1","generated_at":"2026-04-22T23:21:57+00:00","cve":"CVE-2018-3991","urls":{"html":"https://cve.report/CVE-2018-3991","api":"https://cve.report/api/cve/CVE-2018-3991.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2018-3991","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2018-3991"},"summary":{"title":"CVE-2018-3991","description":"An exploitable heap overflow vulnerability exists in the WkbProgramLow function of WibuKey Network server management, version 6.40.2402.500. A specially crafted TCP packet can cause a heap overflow, potentially leading to remote code execution. An attacker can send a malformed TCP packet to trigger this vulnerability.","state":"PUBLIC","assigner":"talos-cna@cisco.com","published_at":"2019-02-05 23:29:00","updated_at":"2022-04-19 18:15:00"},"problem_types":["CWE-787"],"metrics":[],"references":[{"url":"http://www.securityfocus.com/bid/107005","name":"107005","refsource":"BID","tags":["Third Party Advisory","VDB Entry"],"title":"Wibu Systems WibuKey DRM Multiple Input Validation Vulnerabilities","mime":"text/html","httpstatus":"200","archivestatus":"0"},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-902727.pdf","name":"https://cert-portal.siemens.com/productcert/pdf/ssa-902727.pdf","refsource":"CONFIRM","tags":[],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"200"},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-760124.pdf","name":"https://cert-portal.siemens.com/productcert/pdf/ssa-760124.pdf","refsource":"CONFIRM","tags":["Mitigation","Third Party Advisory"],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"200"},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-844562.pdf","name":"https://cert-portal.siemens.com/productcert/pdf/ssa-844562.pdf","refsource":"CONFIRM","tags":["Third Party Advisory"],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"200"},{"url":"https://talosintelligence.com/vulnerability_reports/TALOS-2018-0659","name":"https://talosintelligence.com/vulnerability_reports/TALOS-2018-0659","refsource":"MISC","tags":["Exploit","Third Party Advisory"],"title":"TALOS-2018-0659 ||  Cisco Talos Intelligence Group - Comprehensive Threat Intelligence","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2018-3991","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2018-3991","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2018","cve_id":"3991","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"microsoft","cpe5":"windows","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2018","cve_id":"3991","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"microsoft","cpe5":"windows","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2018","cve_id":"3991","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"simatic_wincc_open_architecture","cpe6":"3.14","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2018","cve_id":"3991","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"simatic_wincc_open_architecture","cpe6":"3.15","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2018","cve_id":"3991","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"simatic_wincc_open_architecture","cpe6":"3.16","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2018","cve_id":"3991","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"simatic_wincc_open_architecture","cpe6":"3.14","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2018","cve_id":"3991","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"simatic_wincc_open_architecture","cpe6":"3.15","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2018","cve_id":"3991","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"simatic_wincc_open_architecture","cpe6":"3.16","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2018","cve_id":"3991","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"wibu","cpe5":"wibukey","cpe6":"6.40.2402.500","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2018","cve_id":"3991","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"wibu","cpe5":"wibukey","cpe6":"6.40.2402.500","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"talos-cna@cisco.com","ID":"CVE-2018-3991","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"n/a","version":{"version_data":[{"version_value":"n/a"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"An exploitable heap overflow vulnerability exists in the WkbProgramLow function of WibuKey Network server management, version 6.40.2402.500. A specially crafted TCP packet can cause a heap overflow, potentially leading to remote code execution. An attacker can send a malformed TCP packet to trigger this vulnerability."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"n/a"}]}]},"references":{"reference_data":[{"name":"107005","refsource":"BID","url":"http://www.securityfocus.com/bid/107005"},{"name":"https://cert-portal.siemens.com/productcert/pdf/ssa-844562.pdf","refsource":"CONFIRM","url":"https://cert-portal.siemens.com/productcert/pdf/ssa-844562.pdf"},{"name":"https://cert-portal.siemens.com/productcert/pdf/ssa-760124.pdf","refsource":"CONFIRM","url":"https://cert-portal.siemens.com/productcert/pdf/ssa-760124.pdf"},{"refsource":"CONFIRM","name":"https://cert-portal.siemens.com/productcert/pdf/ssa-902727.pdf","url":"https://cert-portal.siemens.com/productcert/pdf/ssa-902727.pdf"},{"name":"https://talosintelligence.com/vulnerability_reports/TALOS-2018-0659","refsource":"MISC","url":"https://talosintelligence.com/vulnerability_reports/TALOS-2018-0659"}]},"impact":{"cvss":{"baseScore":10,"baseSeverity":null,"vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H","version":"3.0"}}},"nvd":{"publishedDate":"2019-02-05 23:29:00","lastModifiedDate":"2022-04-19 18:15:00","problem_types":["CWE-787"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":9.8,"baseSeverity":"CRITICAL"},"exploitabilityScore":3.9,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:P/A:P","accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL","baseScore":7.5},"severity":"HIGH","exploitabilityScore":10,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:wibu:wibukey:6.40.2402.500:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:o:microsoft:windows:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:simatic_wincc_open_architecture:3.15:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:simatic_wincc_open_architecture:3.16:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:simatic_wincc_open_architecture:3.14:*:*:*:*:*:*:*","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2018","CveId":"3991","Ordinal":"119905","Title":"CVE-2018-3991","CVE":"CVE-2018-3991","Year":"2018"},"notes":[{"CveYear":"2018","CveId":"3991","Ordinal":"1","NoteData":"An exploitable heap overflow vulnerability exists in the WkbProgramLow function of WibuKey Network server management, version 6.40.2402.500. A specially crafted TCP packet can cause a heap overflow, potentially leading to remote code execution. An attacker can send a malformed TCP packet to trigger this vulnerability.","Type":"Description","Title":null},{"CveYear":"2018","CveId":"3991","Ordinal":"2","NoteData":"2019-02-05","Type":"Other","Title":"Published"},{"CveYear":"2018","CveId":"3991","Ordinal":"3","NoteData":"2019-05-14","Type":"Other","Title":"Modified"}]}}}