{"api_version":"1","generated_at":"2026-04-23T05:05:30+00:00","cve":"CVE-2018-4835","urls":{"html":"https://cve.report/CVE-2018-4835","api":"https://cve.report/api/cve/CVE-2018-4835.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2018-4835","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2018-4835"},"summary":{"title":"CVE-2018-4835","description":"A vulnerability has been identified in TeleControl Server Basic < V3.1. An attacker with network access to the TeleControl Server Basic's port 8000/tcp could bypass the authentication mechanism and read limited information.","state":"PUBLIC","assigner":"productcert@siemens.com","published_at":"2018-01-25 14:29:00","updated_at":"2019-10-09 23:41:00"},"problem_types":["CWE-200"],"metrics":[],"references":[{"url":"http://www.securityfocus.com/bid/102894","name":"102894","refsource":"BID","tags":["Third Party Advisory","VDB Entry"],"title":"Siemens TeleControl Server Basic CVE-2018-4835 Authentication Bypass Vulnerability","mime":"text/html","httpstatus":"200","archivestatus":"0"},{"url":"http://www.securityfocus.com/bid/102904","name":"102904","refsource":"BID","tags":["Third Party Advisory","VDB Entry"],"title":"Siemens TeleControl Server Basic Multiple Security Vulnerabilities","mime":"text/html","httpstatus":"200","archivestatus":"0"},{"url":"https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-651454.pdf","name":"https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-651454.pdf","refsource":"CONFIRM","tags":["Patch","Vendor Advisory"],"title":"Siemens","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"https://www.cve.org/CVERecord?id=CVE-2018-4835","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2018-4835","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2018","cve_id":"4835","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"telecontrol_server_basic","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2018","cve_id":"4835","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"telecontrol_server_basic","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"productcert@siemens.com","DATE_PUBLIC":"2018-01-25T00:00:00","ID":"CVE-2018-4835","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"TeleControl Server Basic","version":{"version_data":[{"version_value":"All versions < V3.1"}]}}]},"vendor_name":"Siemens AG"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"A vulnerability has been identified in TeleControl Server Basic < V3.1. An attacker with network access to the TeleControl Server Basic's port 8000/tcp could bypass the authentication mechanism and read limited information."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-287: Improper Authentication"}]}]},"references":{"reference_data":[{"name":"https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-651454.pdf","refsource":"CONFIRM","url":"https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-651454.pdf"},{"name":"102894","refsource":"BID","url":"http://www.securityfocus.com/bid/102894"},{"name":"102904","refsource":"BID","url":"http://www.securityfocus.com/bid/102904"}]}},"nvd":{"publishedDate":"2018-01-25 14:29:00","lastModifiedDate":"2019-10-09 23:41:00","problem_types":["CWE-200"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"NONE","availabilityImpact":"NONE","baseScore":5.3,"baseSeverity":"MEDIUM"},"exploitabilityScore":3.9,"impactScore":1.4},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:N/A:N","accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"NONE","availabilityImpact":"NONE","baseScore":5},"severity":"MEDIUM","exploitabilityScore":10,"impactScore":2.9,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*","versionEndExcluding":"3.1","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2018","CveId":"4835","Ordinal":"120749","Title":"CVE-2018-4835","CVE":"CVE-2018-4835","Year":"2018"},"notes":[{"CveYear":"2018","CveId":"4835","Ordinal":"1","NoteData":"A vulnerability has been identified in TeleControl Server Basic < V3.1. An attacker with network access to the TeleControl Server Basic's port 8000/tcp could bypass the authentication mechanism and read limited information.","Type":"Description","Title":null},{"CveYear":"2018","CveId":"4835","Ordinal":"2","NoteData":"2018-01-25","Type":"Other","Title":"Published"},{"CveYear":"2018","CveId":"4835","Ordinal":"3","NoteData":"2018-02-03","Type":"Other","Title":"Modified"}]}}}