{"api_version":"1","generated_at":"2026-04-22T19:59:34+00:00","cve":"CVE-2018-5474","urls":{"html":"https://cve.report/CVE-2018-5474","api":"https://cve.report/api/cve/CVE-2018-5474.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2018-5474","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2018-5474"},"summary":{"title":"CVE-2018-5474","description":"Philips Intellispace Portal all versions 7.0.x and 8.0.x have an input validation vulnerability that could allow a remote attacker to execute arbitrary code or cause the application to crash.","state":"PUBLIC","assigner":"ics-cert@hq.dhs.gov","published_at":"2018-03-26 14:29:00","updated_at":"2019-10-09 23:41:00"},"problem_types":["CWE-20"],"metrics":[],"references":[{"url":"https://ics-cert.us-cert.gov/advisories/ICSMA-18-058-02","name":"https://ics-cert.us-cert.gov/advisories/ICSMA-18-058-02","refsource":"MISC","tags":["Third Party Advisory","US Government Resource"],"title":"Philips Intellispace Portal ISP Vulnerabilities | ICS-CERT","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"http://www.securityfocus.com/bid/103182","name":"103182","refsource":"BID","tags":["Third Party Advisory","VDB Entry"],"title":"Philips Intellispace Portal Multiple Security Vulnerabilities","mime":"text/html","httpstatus":"200","archivestatus":"0"},{"url":"https://www.usa.philips.com/healthcare/about/customer-support/product-security","name":"https://www.usa.philips.com/healthcare/about/customer-support/product-security","refsource":"CONFIRM","tags":["Vendor Advisory"],"title":"Product Security | Philips","mime":"text/html","httpstatus":"200","archivestatus":"403"},{"url":"https://www.cve.org/CVERecord?id=CVE-2018-5474","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2018-5474","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2018","cve_id":"5474","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"philips","cpe5":"intellispace_portal","cpe6":"8.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2018","cve_id":"5474","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"philips","cpe5":"intellispace_portal","cpe6":"9.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2018","cve_id":"5474","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"philips","cpe5":"intellispace_portal","cpe6":"8.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2018","cve_id":"5474","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"philips","cpe5":"intellispace_portal","cpe6":"9.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","DATE_PUBLIC":"2018-02-27T00:00:00","ID":"CVE-2018-5474","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Philips IntelliSpace Portal","version":{"version_data":[{"version_value":"8.0.x"},{"version_value":"7.0.x"}]}}]},"vendor_name":"Philips"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Philips Intellispace Portal all versions 7.0.x and 8.0.x have an input validation vulnerability that could allow a remote attacker to execute arbitrary code or cause the application to crash."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"IMPROPER INPUT VALIDATION CWE-20"}]}]},"references":{"reference_data":[{"name":"https://www.usa.philips.com/healthcare/about/customer-support/product-security","refsource":"CONFIRM","url":"https://www.usa.philips.com/healthcare/about/customer-support/product-security"},{"name":"103182","refsource":"BID","url":"http://www.securityfocus.com/bid/103182"},{"name":"https://ics-cert.us-cert.gov/advisories/ICSMA-18-058-02","refsource":"MISC","url":"https://ics-cert.us-cert.gov/advisories/ICSMA-18-058-02"}]}},"nvd":{"publishedDate":"2018-03-26 14:29:00","lastModifiedDate":"2019-10-09 23:41:00","problem_types":["CWE-20"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":9.8,"baseSeverity":"CRITICAL"},"exploitabilityScore":3.9,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:P/A:P","accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL","baseScore":7.5},"severity":"HIGH","exploitabilityScore":10,"impactScore":6.4,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:philips:intellispace_portal:9.0:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:philips:intellispace_portal:8.0:*:*:*:*:*:*:*","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2018","CveId":"5474","Ordinal":"121444","Title":"CVE-2018-5474","CVE":"CVE-2018-5474","Year":"2018"},"notes":[{"CveYear":"2018","CveId":"5474","Ordinal":"1","NoteData":"Philips Intellispace Portal all versions 7.0.x and 8.0.x have an input validation vulnerability that could allow a remote attacker to execute arbitrary code or cause the application to crash.","Type":"Description","Title":null},{"CveYear":"2018","CveId":"5474","Ordinal":"2","NoteData":"2018-03-26","Type":"Other","Title":"Published"},{"CveYear":"2018","CveId":"5474","Ordinal":"3","NoteData":"2018-03-27","Type":"Other","Title":"Modified"}]}}}