{"api_version":"1","generated_at":"2026-05-06T21:27:08+00:00","cve":"CVE-2018-5476","urls":{"html":"https://cve.report/CVE-2018-5476","api":"https://cve.report/api/cve/CVE-2018-5476.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2018-5476","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2018-5476"},"summary":{"title":"CVE-2018-5476","description":"A Stack-based Buffer Overflow issue was discovered in Delta Electronics Delta Industrial Automation DOPSoft, Version 4.00.01 or prior. Stack-based buffer overflow vulnerabilities caused by processing specially crafted .dop or .dpb files may allow an attacker to remotely execute arbitrary code.","state":"PUBLIC","assigner":"ics-cert@hq.dhs.gov","published_at":"2018-03-15 23:29:00","updated_at":"2020-09-18 16:08:00"},"problem_types":["CWE-787"],"metrics":[],"references":[{"url":"http://www.securityfocus.com/bid/103195","name":"103195","refsource":"BID","tags":["Third Party Advisory","VDB Entry"],"title":"","mime":"text/html","httpstatus":"200","archivestatus":"0"},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-18-060-03","name":"https://ics-cert.us-cert.gov/advisories/ICSA-18-060-03","refsource":"MISC","tags":["Third Party Advisory","US Government Resource"],"title":"Delta Electronics Delta Industrial Automation DOPSoft | ICS-CERT","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2018-5476","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2018-5476","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2018","cve_id":"5476","vulnerable":"1","versionEndIncluding":"4.00.01","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"deltaww","cpe5":"delta_industrial_automation_dopsoft","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","ID":"CVE-2018-5476","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Delta Electronics Delta Industrial Automation DOPSoft","version":{"version_data":[{"version_value":"Delta Electronics Delta Industrial Automation DOPSoft"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"A Stack-based Buffer Overflow issue was discovered in Delta Electronics Delta Industrial Automation DOPSoft, Version 4.00.01 or prior. Stack-based buffer overflow vulnerabilities caused by processing specially crafted .dop or .dpb files may allow an attacker to remotely execute arbitrary code."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-121"}]}]},"references":{"reference_data":[{"name":"103195","refsource":"BID","url":"http://www.securityfocus.com/bid/103195"},{"name":"https://ics-cert.us-cert.gov/advisories/ICSA-18-060-03","refsource":"MISC","url":"https://ics-cert.us-cert.gov/advisories/ICSA-18-060-03"}]}},"nvd":{"publishedDate":"2018-03-15 23:29:00","lastModifiedDate":"2020-09-18 16:08:00","problem_types":["CWE-787"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:P/I:P/A:P","accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL","baseScore":6.8},"severity":"MEDIUM","exploitabilityScore":8.6,"impactScore":6.4,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:deltaww:delta_industrial_automation_dopsoft:*:*:*:*:*:*:*:*","versionEndIncluding":"4.00.01","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2018","CveId":"5476","Ordinal":"121446","Title":"CVE-2018-5476","CVE":"CVE-2018-5476","Year":"2018"},"notes":[{"CveYear":"2018","CveId":"5476","Ordinal":"1","NoteData":"A Stack-based Buffer Overflow issue was discovered in Delta Electronics Delta Industrial Automation DOPSoft, Version 4.00.01 or prior. Stack-based buffer overflow vulnerabilities caused by processing specially crafted .dop or .dpb files may allow an attacker to remotely execute arbitrary code.","Type":"Description","Title":null},{"CveYear":"2018","CveId":"5476","Ordinal":"2","NoteData":"2018-03-15","Type":"Other","Title":"Published"},{"CveYear":"2018","CveId":"5476","Ordinal":"3","NoteData":"2018-03-16","Type":"Other","Title":"Modified"}]}}}