{"api_version":"1","generated_at":"2026-04-26T18:53:24+00:00","cve":"CVE-2018-7494","urls":{"html":"https://cve.report/CVE-2018-7494","api":"https://cve.report/api/cve/CVE-2018-7494.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2018-7494","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2018-7494"},"summary":{"title":"CVE-2018-7494","description":"WPLSoft in Delta Electronics versions 2.45.0 and prior utilizes a fixed length stack buffer where a value larger than the buffer can be read from a file into the buffer, causing the buffer to be overwritten, which may allow remote code execution or cause the application to crash.","state":"PUBLIC","assigner":"ics-cert@hq.dhs.gov","published_at":"2018-05-04 19:29:00","updated_at":"2019-10-09 23:42:00"},"problem_types":["CWE-119"],"metrics":[],"references":[{"url":"http://www.securityfocus.com/bid/103179","name":"103179","refsource":"BID","tags":["Third Party Advisory","VDB Entry"],"title":"Malformed Request","mime":"text/html","httpstatus":"200","archivestatus":"0"},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-18-058-02","name":"https://ics-cert.us-cert.gov/advisories/ICSA-18-058-02","refsource":"MISC","tags":["Third Party Advisory","US Government Resource"],"title":"Delta Electronics WPLSoft | ICS-CERT","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2018-7494","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2018-7494","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2018","cve_id":"7494","vulnerable":"1","versionEndIncluding":"2.45.0","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"deltaww","cpe5":"wplsoft","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","DATE_PUBLIC":"2018-02-27T00:00:00","ID":"CVE-2018-7494","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Delta Electronics WPLSoft","version":{"version_data":[{"version_value":"WPLSoft, Versions 2.45.0 and prior."}]}}]},"vendor_name":"ICS-CERT"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"WPLSoft in Delta Electronics versions 2.45.0 and prior utilizes a fixed length stack buffer where a value larger than the buffer can be read from a file into the buffer, causing the buffer to be overwritten, which may allow remote code execution or cause the application to crash."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"STACK-BASED BUFFER OVERFLOW CWE-121"}]}]},"references":{"reference_data":[{"name":"103179","refsource":"BID","url":"http://www.securityfocus.com/bid/103179"},{"name":"https://ics-cert.us-cert.gov/advisories/ICSA-18-058-02","refsource":"MISC","url":"https://ics-cert.us-cert.gov/advisories/ICSA-18-058-02"}]}},"nvd":{"publishedDate":"2018-05-04 19:29:00","lastModifiedDate":"2019-10-09 23:42:00","problem_types":["CWE-119"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":8.8,"baseSeverity":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:P/I:P/A:P","accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL","baseScore":6.8},"severity":"MEDIUM","exploitabilityScore":8.6,"impactScore":6.4,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:deltaww:wplsoft:*:*:*:*:*:*:*:*","versionEndIncluding":"2.45.0","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2018","CveId":"7494","Ordinal":"123776","Title":"CVE-2018-7494","CVE":"CVE-2018-7494","Year":"2018"},"notes":[{"CveYear":"2018","CveId":"7494","Ordinal":"1","NoteData":"WPLSoft in Delta Electronics versions 2.45.0 and prior utilizes a fixed length stack buffer where a value larger than the buffer can be read from a file into the buffer, causing the buffer to be overwritten, which may allow remote code execution or cause the application to crash.","Type":"Description","Title":null},{"CveYear":"2018","CveId":"7494","Ordinal":"2","NoteData":"2018-05-04","Type":"Other","Title":"Published"},{"CveYear":"2018","CveId":"7494","Ordinal":"3","NoteData":"2018-05-05","Type":"Other","Title":"Modified"}]}}}