{"api_version":"1","generated_at":"2026-06-03T09:52:36+00:00","cve":"CVE-2018-7789","urls":{"html":"https://cve.report/CVE-2018-7789","api":"https://cve.report/api/cve/CVE-2018-7789.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2018-7789","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2018-7789"},"summary":{"title":"CVE-2018-7789","description":"An Improper Check for Unusual or Exceptional Conditions vulnerability exists in Schneider Electric's Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to remotely reboot Modicon M221 using crafted programing protocol frames.","state":"PUBLISHED","assigner":"schneider","published_at":"2018-08-29 20:29:00","updated_at":"2026-05-29 15:16:16"},"problem_types":["CWE-754","Improper Check for Unusual or Exceptional Conditions","CWE-754 CWE-754 Improper Check for Unusual or Exceptional Conditions"],"metrics":[{"version":"3.1","source":"nvd@nist.gov","type":"Primary","score":"7.5","severity":"HIGH","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"}},{"version":"3.1","source":"ADP","type":"DECLARED","score":"4.8","severity":"MEDIUM","vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:L","data":{"attackComplexity":"HIGH","attackVector":"NETWORK","availabilityImpact":"LOW","baseScore":4.8,"baseSeverity":"MEDIUM","confidentialityImpact":"NONE","integrityImpact":"LOW","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:L","version":"3.1"}},{"version":"3.1","source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","score":"4.8","severity":"MEDIUM","vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:L","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:L","baseScore":4.8,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"LOW","availabilityImpact":"LOW"}},{"version":"2.0","source":"nvd@nist.gov","type":"Primary","score":"7.8","severity":"","vector":"AV:N/AC:L/Au:N/C:N/I:N/A:C","data":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:N/I:N/A:C","baseScore":7.8,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"COMPLETE"}}],"references":[{"url":"https://www.schneider-electric.com/en/download/document/SEVD-2018-233-01/","name":"https://www.schneider-electric.com/en/download/document/SEVD-2018-233-01/","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Mitigation","Vendor Advisory"],"title":"Security Notification - Modicon M221 | Schneider Electric","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-18-240-02","name":"https://ics-cert.us-cert.gov/advisories/ICSA-18-240-02","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Mitigation","Third Party Advisory","US Government Resource"],"title":"Schneider Electric Modicon M221 | ICS-CERT","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"http://www.securityfocus.com/bid/105171","name":"http://www.securityfocus.com/bid/105171","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","VDB Entry"],"title":"Malformed Request","mime":"text/html","httpstatus":"200","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2018-7789","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2018-7789","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"Schneider Electric SE","product":"Modicon M221, all references, all versions prior to firmware V1.6.2.0","version":"affected Modicon M221, all references, all versions prior to firmware V1.6.2.0","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2018","cve_id":"7789","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"schneider-electric","cpe5":"modicon_m221","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2018","cve_id":"7789","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"schneider-electric","cpe5":"modicon_m221_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":{"cve_year":"2018","cve_id":"7789","cve":"CVE-2018-7789","epss":"0.007920000","percentile":"0.742230000","score_date":"2026-06-02","updated_at":"2026-06-03 00:08:16"},"legacy_qids":[{"cve":"CVE-2018-7789","qid":"590483","title":"Schneider Electric Modicon M221 Multiple Vulnerabilities (ICSA-18-240-02,ICSA-18-240-01)"}]},"source_records":{"cve_program":{"containers":{"adp":[{"providerMetadata":{"dateUpdated":"2024-08-05T06:37:59.299Z","orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE"},"references":[{"tags":["x_refsource_MISC","x_transferred"],"url":"https://ics-cert.us-cert.gov/advisories/ICSA-18-240-02"},{"tags":["x_refsource_CONFIRM","x_transferred"],"url":"https://www.schneider-electric.com/en/download/document/SEVD-2018-233-01/"},{"name":"105171","tags":["vdb-entry","x_refsource_BID","x_transferred"],"url":"http://www.securityfocus.com/bid/105171"}],"title":"CVE Program Container"},{"metrics":[{"cvssV3_1":{"attackComplexity":"HIGH","attackVector":"NETWORK","availabilityImpact":"LOW","baseScore":4.8,"baseSeverity":"MEDIUM","confidentialityImpact":"NONE","integrityImpact":"LOW","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:L","version":"3.1"}},{"other":{"content":{"id":"CVE-2018-7789","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","timestamp":"2026-05-29T13:42:20.871154Z","version":"2.0.3"},"type":"ssvc"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-754","description":"CWE-754 Improper Check for Unusual or Exceptional Conditions","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2026-05-29T13:50:59.507Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"product":"Modicon M221, all references, all versions prior to firmware V1.6.2.0","vendor":"Schneider Electric SE","versions":[{"status":"affected","version":"Modicon M221, all references, all versions prior to firmware V1.6.2.0"}]}],"datePublic":"2018-08-21T00:00:00.000Z","descriptions":[{"lang":"en","value":"An Improper Check for Unusual or Exceptional Conditions vulnerability exists in Schneider Electric's Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to remotely reboot Modicon M221 using crafted programing protocol frames."}],"problemTypes":[{"descriptions":[{"description":"Improper Check for Unusual or Exceptional Conditions","lang":"en","type":"text"}]}],"providerMetadata":{"dateUpdated":"2018-08-30T19:57:02.000Z","orgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","shortName":"schneider"},"references":[{"tags":["x_refsource_MISC"],"url":"https://ics-cert.us-cert.gov/advisories/ICSA-18-240-02"},{"tags":["x_refsource_CONFIRM"],"url":"https://www.schneider-electric.com/en/download/document/SEVD-2018-233-01/"},{"name":"105171","tags":["vdb-entry","x_refsource_BID"],"url":"http://www.securityfocus.com/bid/105171"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"cybersecurity@schneider-electric.com","DATE_PUBLIC":"2018-08-21T00:00:00","ID":"CVE-2018-7789","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Modicon M221, all references, all versions prior to firmware V1.6.2.0","version":{"version_data":[{"version_value":"Modicon M221, all references, all versions prior to firmware V1.6.2.0"}]}}]},"vendor_name":"Schneider Electric SE"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"An Improper Check for Unusual or Exceptional Conditions vulnerability exists in Schneider Electric's Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to remotely reboot Modicon M221 using crafted programing protocol frames."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"Improper Check for Unusual or Exceptional Conditions"}]}]},"references":{"reference_data":[{"name":"https://ics-cert.us-cert.gov/advisories/ICSA-18-240-02","refsource":"MISC","url":"https://ics-cert.us-cert.gov/advisories/ICSA-18-240-02"},{"name":"https://www.schneider-electric.com/en/download/document/SEVD-2018-233-01/","refsource":"CONFIRM","url":"https://www.schneider-electric.com/en/download/document/SEVD-2018-233-01/"},{"name":"105171","refsource":"BID","url":"http://www.securityfocus.com/bid/105171"}]}}}},"cveMetadata":{"assignerOrgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","assignerShortName":"schneider","cveId":"CVE-2018-7789","datePublished":"2018-08-29T20:00:00.000Z","dateReserved":"2018-03-08T00:00:00.000Z","dateUpdated":"2026-05-29T13:50:59.507Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2018-08-29 20:29:00","lastModifiedDate":"2026-05-29 15:16:16","problem_types":["CWE-754","Improper Check for Unusual or Exceptional Conditions","CWE-754 CWE-754 Improper Check for Unusual or Exceptional Conditions"],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":3.6},{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:L","baseScore":4.8,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"LOW","availabilityImpact":"LOW"},"exploitabilityScore":2.2,"impactScore":2.5}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:N/I:N/A:C","baseScore":7.8,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"COMPLETE"},"baseSeverity":"HIGH","exploitabilityScore":10,"impactScore":6.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:modicon_m221_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.6.2.0","matchCriteriaId":"55D26878-E5EB-4537-A252-34B3EBB758CC"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:modicon_m221:-:*:*:*:*:*:*:*","matchCriteriaId":"BB0D83F4-B718-47AB-AFB8-B576CB138AAC"}]}]}]},"legacy_mitre":{"record":{"CveYear":"2018","CveId":"7789","Ordinal":"1","Title":"CVE-2018-7789","CVE":"CVE-2018-7789","Year":"2018"},"notes":[{"CveYear":"2018","CveId":"7789","Ordinal":"1","NoteData":"An Improper Check for Unusual or Exceptional Conditions vulnerability exists in Schneider Electric's Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to remotely reboot Modicon M221 using crafted programing protocol frames.","Type":"Description","Title":"CVE-2018-7789"},{"CveYear":"2018","CveId":"7789","Ordinal":"2","NoteData":"2018-08-29","Type":"Other","Title":"Published"},{"CveYear":"2018","CveId":"7789","Ordinal":"3","NoteData":"2018-08-30","Type":"Other","Title":"Modified"}]}}}