{"api_version":"1","generated_at":"2026-07-24T19:35:00+00:00","cve":"CVE-2018-7793","urls":{"html":"https://cve.report/CVE-2018-7793","api":"https://cve.report/api/cve/CVE-2018-7793.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2018-7793","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2018-7793"},"summary":{"title":"CVE-2018-7793","description":"A Credential Management vulnerability exists in FoxView HMI SCADA (All Foxboro DCS, Foxboro Evo, and IA Series versions prior to Foxboro DCS Control Core Services 9.4 (CCS 9.4) and FoxView 10.5.) which could cause unauthorized disclosure, modification, or disruption in service when the password is modified without permission.","state":"PUBLIC","assigner":"cybersecurity@schneider-electric.com","published_at":"2018-12-24 16:29:00","updated_at":"2020-08-24 17:37:00"},"problem_types":["NVD-CWE-noinfo"],"metrics":[],"references":[{"url":"https://www.schneider-electric.com/en/download/document/SEVD-2018-353-03/","name":"https://www.schneider-electric.com/en/download/document/SEVD-2018-353-03/","refsource":"CONFIRM","tags":["Vendor Advisory"],"title":"Security Notification - FoxView HMI SCADA | Schneider Electric","mime":"text/html","httpstatus":"200","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2018-7793","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2018-7793","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2018","cve_id":"7793","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"foxboro_dcs","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2018","cve_id":"7793","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"foxboro_dcs","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2018","cve_id":"7793","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"foxboro_evo","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2018","cve_id":"7793","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"foxboro_evo","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2018","cve_id":"7793","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"foxview","cpe6":"10.5","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2018","cve_id":"7793","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"foxview","cpe6":"10.5","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2018","cve_id":"7793","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"ia_series","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2018","cve_id":"7793","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"ia_series","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"cybersecurity@schneider-electric.com","ID":"CVE-2018-7793","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"FoxView HMI SCADA (All Foxboro DCS, Foxboro Evo, and IA Series versions prior to Foxboro DCS Control Core Services 9.4 (CCS 9.4) and FoxView 10.5.)","version":{"version_data":[{"version_value":"FoxView HMI SCADA (All Foxboro DCS, Foxboro Evo, and IA Series versions prior to Foxboro DCS Control Core Services 9.4 (CCS 9.4) and FoxView 10.5.)"}]}}]},"vendor_name":"Schneider Electric SE"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"A Credential Management vulnerability exists in FoxView HMI SCADA (All Foxboro DCS, Foxboro Evo, and IA Series versions prior to Foxboro DCS Control Core Services 9.4 (CCS 9.4) and FoxView 10.5.) which could cause unauthorized disclosure, modification, or disruption in service when the password is modified without permission."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"Credential Management"}]}]},"references":{"reference_data":[{"name":"https://www.schneider-electric.com/en/download/document/SEVD-2018-353-03/","refsource":"CONFIRM","url":"https://www.schneider-electric.com/en/download/document/SEVD-2018-353-03/"}]}},"nvd":{"publishedDate":"2018-12-24 16:29:00","lastModifiedDate":"2020-08-24 17:37:00","problem_types":["NVD-CWE-noinfo"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.0","vectorString":"CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:L","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"CHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"LOW","baseScore":8.7,"baseSeverity":"HIGH"},"exploitabilityScore":2,"impactScore":6},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:L/AC:L/Au:N/C:P/I:P/A:P","accessVector":"LOCAL","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL","baseScore":4.6},"severity":"MEDIUM","exploitabilityScore":3.9,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:schneider-electric:foxview:10.5:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:schneider-electric:ia_series:*:*:*:*:*:*:*:*","versionEndExcluding":"ccs_9.4","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:schneider-electric:foxboro_evo:*:*:*:*:*:*:*:*","versionEndExcluding":"ccs_9.4","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:schneider-electric:foxboro_dcs:*:*:*:*:*:*:*:*","versionEndExcluding":"ccs_9.4","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2018","CveId":"7793","Ordinal":"124107","Title":"CVE-2018-7793","CVE":"CVE-2018-7793","Year":"2018"},"notes":[{"CveYear":"2018","CveId":"7793","Ordinal":"1","NoteData":"A Credential Management vulnerability exists in FoxView HMI SCADA (All Foxboro DCS, Foxboro Evo, and IA Series versions prior to Foxboro DCS Control Core Services 9.4 (CCS 9.4) and FoxView 10.5.) which could cause unauthorized disclosure, modification, or disruption in service when the password is modified without permission.","Type":"Description","Title":null},{"CveYear":"2018","CveId":"7793","Ordinal":"2","NoteData":"2018-12-24","Type":"Other","Title":"Published"},{"CveYear":"2018","CveId":"7793","Ordinal":"3","NoteData":"2018-12-24","Type":"Other","Title":"Modified"}]}}}