{"api_version":"1","generated_at":"2026-05-06T07:23:54+00:00","cve":"CVE-2018-7832","urls":{"html":"https://cve.report/CVE-2018-7832","api":"https://cve.report/api/cve/CVE-2018-7832.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2018-7832","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2018-7832"},"summary":{"title":"CVE-2018-7832","description":"An Improper Input Validation vulnerability exists in Pro-Face GP-Pro EX v4.08 and previous versions which could cause the execution arbitrary executable when GP-Pro EX is launched.","state":"PUBLIC","assigner":"cybersecurity@schneider-electric.com","published_at":"2018-12-24 16:29:00","updated_at":"2019-05-28 18:29:00"},"problem_types":["CWE-20"],"metrics":[],"references":[{"url":"http://www.securityfocus.com/bid/106441","name":"106441","refsource":"BID","tags":["Third Party Advisory","VDB Entry"],"title":"","mime":"text/html","httpstatus":"200","archivestatus":"0"},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-19-003-01","name":"https://ics-cert.us-cert.gov/advisories/ICSA-19-003-01","refsource":"MISC","tags":[],"title":"Schneider Electric Pro-face GP-Pro EX | ICS-CERT","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.schneider-electric.com/en/download/document/SEVD-2018-354-02/","name":"https://www.schneider-electric.com/en/download/document/SEVD-2018-354-02/","refsource":"CONFIRM","tags":["Vendor Advisory"],"title":"","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2018-7832","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2018-7832","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2018","cve_id":"7832","vulnerable":"1","versionEndIncluding":"4.08","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"pro-face_gp-pro_ex","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"cybersecurity@schneider-electric.com","ID":"CVE-2018-7832","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Pro-Face GP-Pro EX v4.08 and previous versions","version":{"version_data":[{"version_value":"Pro-Face GP-Pro EX v4.08 and previous versions"}]}}]},"vendor_name":"Schneider Electric SE"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"An Improper Input Validation vulnerability exists in Pro-Face GP-Pro EX v4.08 and previous versions which could cause the execution arbitrary executable when GP-Pro EX is launched."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"Improper Input Validation"}]}]},"references":{"reference_data":[{"name":"https://www.schneider-electric.com/en/download/document/SEVD-2018-354-02/","refsource":"CONFIRM","url":"https://www.schneider-electric.com/en/download/document/SEVD-2018-354-02/"},{"name":"106441","refsource":"BID","url":"http://www.securityfocus.com/bid/106441"},{"refsource":"MISC","name":"https://ics-cert.us-cert.gov/advisories/ICSA-19-003-01","url":"https://ics-cert.us-cert.gov/advisories/ICSA-19-003-01"}]}},"nvd":{"publishedDate":"2018-12-24 16:29:00","lastModifiedDate":"2019-05-28 18:29:00","problem_types":["CWE-20"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":8.8,"baseSeverity":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:L/Au:S/C:P/I:P/A:P","accessVector":"NETWORK","accessComplexity":"LOW","authentication":"SINGLE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL","baseScore":6.5},"severity":"MEDIUM","exploitabilityScore":8,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:schneider-electric:pro-face_gp-pro_ex:*:*:*:*:*:*:*:*","versionEndIncluding":"4.08","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2018","CveId":"7832","Ordinal":"124146","Title":"CVE-2018-7832","CVE":"CVE-2018-7832","Year":"2018"},"notes":[{"CveYear":"2018","CveId":"7832","Ordinal":"1","NoteData":"An Improper Input Validation vulnerability exists in Pro-Face GP-Pro EX v4.08 and previous versions which could cause the execution arbitrary executable when GP-Pro EX is launched.","Type":"Description","Title":null},{"CveYear":"2018","CveId":"7832","Ordinal":"2","NoteData":"2018-12-24","Type":"Other","Title":"Published"},{"CveYear":"2018","CveId":"7832","Ordinal":"3","NoteData":"2019-05-28","Type":"Other","Title":"Modified"}]}}}