{"api_version":"1","generated_at":"2026-05-06T23:21:14+00:00","cve":"CVE-2018-7839","urls":{"html":"https://cve.report/CVE-2018-7839","api":"https://cve.report/api/cve/CVE-2018-7839.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2018-7839","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2018-7839"},"summary":{"title":"CVE-2018-7839","description":"A Cryptographic Issue (CWE-310) vulnerability exists in IIoT Monitor 3.1.38 which could allow information disclosure.","state":"PUBLIC","assigner":"cybersecurity@schneider-electric.com","published_at":"2019-02-06 23:29:00","updated_at":"2019-06-07 16:29:00"},"problem_types":["CWE-310"],"metrics":[],"references":[{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-19-008-02","name":"https://ics-cert.us-cert.gov/advisories/ICSA-19-008-02","refsource":"MISC","tags":[],"title":"Schneider Electric IIoT Monitor (Update A) | ICS-CERT","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.schneider-electric.com/en/download/document/SEVD-2018-354-03/","name":"https://www.schneider-electric.com/en/download/document/SEVD-2018-354-03/","refsource":"CONFIRM","tags":["Vendor Advisory"],"title":"Security Notification - IIoT Monitor V1.1 | Schneider Electric","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2018-7839","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2018-7839","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2018","cve_id":"7839","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"iiot_monitor","cpe6":"3.1.38","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2018","cve_id":"7839","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"iiot_monitor","cpe6":"3.1.38","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"cybersecurity@schneider-electric.com","ID":"CVE-2018-7839","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"IIoT Monitor 3.1.38","version":{"version_data":[{"version_value":"IIoT Monitor 3.1.38"}]}}]},"vendor_name":"Schneider Electric SE"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"A Cryptographic Issue (CWE-310) vulnerability exists in IIoT Monitor 3.1.38 which could allow information disclosure."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"Cryptographic Issue"}]}]},"references":{"reference_data":[{"name":"https://www.schneider-electric.com/en/download/document/SEVD-2018-354-03/","refsource":"CONFIRM","url":"https://www.schneider-electric.com/en/download/document/SEVD-2018-354-03/"},{"refsource":"MISC","name":"https://ics-cert.us-cert.gov/advisories/ICSA-19-008-02","url":"https://ics-cert.us-cert.gov/advisories/ICSA-19-008-02"}]}},"nvd":{"publishedDate":"2019-02-06 23:29:00","lastModifiedDate":"2019-06-07 16:29:00","problem_types":["CWE-310"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.0","vectorString":"CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE","baseScore":5.5,"baseSeverity":"MEDIUM"},"exploitabilityScore":1.8,"impactScore":3.6},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:L/AC:L/Au:N/C:P/I:N/A:N","accessVector":"LOCAL","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"NONE","availabilityImpact":"NONE","baseScore":2.1},"severity":"LOW","exploitabilityScore":3.9,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:schneider-electric:iiot_monitor:3.1.38:*:*:*:*:*:*:*","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2018","CveId":"7839","Ordinal":"124153","Title":"CVE-2018-7839","CVE":"CVE-2018-7839","Year":"2018"},"notes":[{"CveYear":"2018","CveId":"7839","Ordinal":"1","NoteData":"A Cryptographic Issue (CWE-310) vulnerability exists in IIoT Monitor 3.1.38 which could allow information disclosure.","Type":"Description","Title":null},{"CveYear":"2018","CveId":"7839","Ordinal":"2","NoteData":"2019-02-06","Type":"Other","Title":"Published"},{"CveYear":"2018","CveId":"7839","Ordinal":"3","NoteData":"2019-06-07","Type":"Other","Title":"Modified"}]}}}