{"api_version":"1","generated_at":"2026-04-22T21:51:49+00:00","cve":"CVE-2018-8848","urls":{"html":"https://cve.report/CVE-2018-8848","api":"https://cve.report/api/cve/CVE-2018-8848.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2018-8848","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2018-8848"},"summary":{"title":"CVE-2018-8848","description":"Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software, upon installation, sets incorrect permissions for an object that exposes it to an unintended actor.","state":"PUBLIC","assigner":"ics-cert@hq.dhs.gov","published_at":"2018-09-26 19:29:00","updated_at":"2020-09-29 19:12:00"},"problem_types":["CWE-732"],"metrics":[],"references":[{"url":"http://www.securityfocus.com/bid/105194","name":"105194","refsource":"BID","tags":["Third Party Advisory","VDB Entry"],"title":"Malformed Request","mime":"text/html","httpstatus":"200","archivestatus":"0"},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-18-242-01","name":"https://ics-cert.us-cert.gov/advisories/ICSA-18-242-01","refsource":"MISC","tags":["Mitigation","Third Party Advisory","US Government Resource"],"title":"Philips e-Alert Unit | ICS-CERT","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.usa.philips.com/healthcare/about/customer-support/product-security","name":"https://www.usa.philips.com/healthcare/about/customer-support/product-security","refsource":"CONFIRM","tags":["Vendor Advisory"],"title":"Product Security | Philips","mime":"text/html","httpstatus":"200","archivestatus":"403"},{"url":"https://www.cve.org/CVERecord?id=CVE-2018-8848","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2018-8848","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2018","cve_id":"8848","vulnerable":"1","versionEndIncluding":"r2.1","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"philips","cpe5":"e-alert_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","DATE_PUBLIC":"2018-08-31T00:00:00","ID":"CVE-2018-8848","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"e-Alert Unit (non-medical device)","version":{"version_data":[{"version_value":"R2.1 and prior"}]}}]},"vendor_name":"Philips"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software, upon installation, sets incorrect permissions for an object that exposes it to an unintended actor."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"INCORRECT DEFAULT PERMISSIONS CWE-276"}]}]},"references":{"reference_data":[{"name":"https://www.usa.philips.com/healthcare/about/customer-support/product-security","refsource":"CONFIRM","url":"https://www.usa.philips.com/healthcare/about/customer-support/product-security"},{"name":"105194","refsource":"BID","url":"http://www.securityfocus.com/bid/105194"},{"name":"https://ics-cert.us-cert.gov/advisories/ICSA-18-242-01","refsource":"MISC","url":"https://ics-cert.us-cert.gov/advisories/ICSA-18-242-01"}]}},"nvd":{"publishedDate":"2018-09-26 19:29:00","lastModifiedDate":"2020-09-29 19:12:00","problem_types":["CWE-732"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE","baseScore":7.5,"baseSeverity":"HIGH"},"exploitabilityScore":3.9,"impactScore":3.6},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:N/A:N","accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"NONE","availabilityImpact":"NONE","baseScore":5},"severity":"MEDIUM","exploitabilityScore":10,"impactScore":2.9,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:philips:e-alert_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"r2.1","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2018","CveId":"8848","Ordinal":"125217","Title":"CVE-2018-8848","CVE":"CVE-2018-8848","Year":"2018"},"notes":[{"CveYear":"2018","CveId":"8848","Ordinal":"1","NoteData":"Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software, upon installation, sets incorrect permissions for an object that exposes it to an unintended actor.","Type":"Description","Title":null},{"CveYear":"2018","CveId":"8848","Ordinal":"2","NoteData":"2018-09-26","Type":"Other","Title":"Published"},{"CveYear":"2018","CveId":"8848","Ordinal":"3","NoteData":"2018-09-27","Type":"Other","Title":"Modified"}]}}}