{"api_version":"1","generated_at":"2026-06-15T03:01:14+00:00","cve":"CVE-2018-8880","urls":{"html":"https://cve.report/CVE-2018-8880","api":"https://cve.report/api/cve/CVE-2018-8880.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2018-8880","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2018-8880"},"summary":{"title":"CVE-2018-8880","description":"Lutron Quantum BACnet Integration 2.0 (firmware 3.2.243) doesn't check for correct user authentication before showing the /deviceIP information, which leads to internal network information disclosure.","state":"PUBLIC","assigner":"cve@mitre.org","published_at":"2018-04-23 18:29:00","updated_at":"2018-05-25 15:39:00"},"problem_types":["CWE-200"],"metrics":[],"references":[{"url":"http://sadfud.me/explotos/deviceip.txt","name":"http://sadfud.me/explotos/deviceip.txt","refsource":"MISC","tags":["Exploit","Third Party Advisory"],"title":"","mime":"text/x-python","httpstatus":"200","archivestatus":"200"},{"url":"https://www.exploit-db.com/exploits/44488/","name":"44488","refsource":"EXPLOIT-DB","tags":["Exploit","Third Party Advisory","VDB Entry"],"title":"Lutron Quantum 2.0 - 3.2.243 - Information Disclosure - Hardware webapps Exploit","mime":"text/html","httpstatus":"200","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2018-8880","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2018-8880","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2018","cve_id":"8880","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"lutron","cpe5":"quantum_bacnet_integration","cpe6":"2.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2018","cve_id":"8880","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"lutron","cpe5":"quantum_bacnet_integration","cpe6":"2.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2018","cve_id":"8880","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"lutron","cpe5":"quantum_bacnet_integration_firmware","cpe6":"3.2.243","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2018","cve_id":"8880","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"lutron","cpe5":"quantum_bacnet_integration_firmware","cpe6":"3.2.243","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"cve@mitre.org","ID":"CVE-2018-8880","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"n/a","version":{"version_data":[{"version_value":"n/a"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Lutron Quantum BACnet Integration 2.0 (firmware 3.2.243) doesn't check for correct user authentication before showing the /deviceIP information, which leads to internal network information disclosure."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"n/a"}]}]},"references":{"reference_data":[{"name":"http://sadfud.me/explotos/deviceip.txt","refsource":"MISC","url":"http://sadfud.me/explotos/deviceip.txt"},{"name":"44488","refsource":"EXPLOIT-DB","url":"https://www.exploit-db.com/exploits/44488/"}]}},"nvd":{"publishedDate":"2018-04-23 18:29:00","lastModifiedDate":"2018-05-25 15:39:00","problem_types":["CWE-200"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE","baseScore":7.5,"baseSeverity":"HIGH"},"exploitabilityScore":3.9,"impactScore":3.6},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:N/A:N","accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"NONE","availabilityImpact":"NONE","baseScore":5},"severity":"MEDIUM","exploitabilityScore":10,"impactScore":2.9,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:lutron:quantum_bacnet_integration_firmware:3.2.243:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:lutron:quantum_bacnet_integration:2.0:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":{"CveYear":"2018","CveId":"8880","Ordinal":"125249","Title":"CVE-2018-8880","CVE":"CVE-2018-8880","Year":"2018"},"notes":[{"CveYear":"2018","CveId":"8880","Ordinal":"1","NoteData":"Lutron Quantum BACnet Integration 2.0 (firmware 3.2.243) doesn't check for correct user authentication before showing the /deviceIP information, which leads to internal network information disclosure.","Type":"Description","Title":null},{"CveYear":"2018","CveId":"8880","Ordinal":"2","NoteData":"2018-04-23","Type":"Other","Title":"Published"},{"CveYear":"2018","CveId":"8880","Ordinal":"3","NoteData":"2018-04-23","Type":"Other","Title":"Modified"}]}}}