{"api_version":"1","generated_at":"2026-04-22T23:08:53+00:00","cve":"CVE-2019-10934","urls":{"html":"https://cve.report/CVE-2019-10934","api":"https://cve.report/api/cve/CVE-2019-10934.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2019-10934","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2019-10934"},"summary":{"title":"CVE-2019-10934","description":"A vulnerability has been identified in TIA Portal V14 (All versions), TIA Portal V15 (All versions < V15.1 Update 7), TIA Portal V16 (All versions < V16 Update 6), TIA Portal V17 (All versions < V17 Update 4). Changing the contents of a configuration file could allow an attacker to execute arbitrary code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system. No user interaction is required. At the time of advisory publication no public exploitation of this security vulnerability was known.","state":"PUBLIC","assigner":"productcert@siemens.com","published_at":"2020-01-16 16:15:00","updated_at":"2022-08-10 20:28:00"},"problem_types":["CWE-22"],"metrics":[],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-629512.pdf","name":"https://cert-portal.siemens.com/productcert/pdf/ssa-629512.pdf","refsource":"MISC","tags":["Vendor Advisory"],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2019-10934","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2019-10934","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2019","cve_id":"10934","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"totally_integrated_automation_portal","cpe6":"15.1","cpe7":"-","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"10934","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"totally_integrated_automation_portal","cpe6":"15.1","cpe7":"update_1","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"10934","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"totally_integrated_automation_portal","cpe6":"15.1","cpe7":"update_2","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"10934","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"totally_integrated_automation_portal","cpe6":"15.1","cpe7":"update_3","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"10934","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"totally_integrated_automation_portal","cpe6":"16","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"10934","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"totally_integrated_automation_portal","cpe6":"15.1","cpe7":"-","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"10934","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"totally_integrated_automation_portal","cpe6":"15.1","cpe7":"update_1","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"10934","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"totally_integrated_automation_portal","cpe6":"15.1","cpe7":"update_2","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"10934","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"totally_integrated_automation_portal","cpe6":"15.1","cpe7":"update_3","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"10934","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"totally_integrated_automation_portal","cpe6":"16","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"10934","vulnerable":"1","versionEndIncluding":"14","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"totally_integrated_automation_portal","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"10934","vulnerable":"1","versionEndIncluding":"17","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"totally_integrated_automation_portal","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[{"cve":"CVE-2019-10934","qid":"591194","title":"Siemens TIA Portal Local Privilege Escalation Vulnerability (SSA-629512)"}]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"productcert@siemens.com","ID":"CVE-2019-10934","STATE":"PUBLIC"},"data_format":"MITRE","data_version":"4.0","data_type":"CVE","affects":{"vendor":{"vendor_data":[{"vendor_name":"Siemens","product":{"product_data":[{"product_name":"TIA Portal V14","version":{"version_data":[{"version_value":"All versions"}]}},{"product_name":"TIA Portal V15","version":{"version_data":[{"version_value":"All versions < V15.1 Update 7"}]}},{"product_name":"TIA Portal V16","version":{"version_data":[{"version_value":"All versions < V16 Update 6"}]}},{"product_name":"TIA Portal V17","version":{"version_data":[{"version_value":"All versions < V17 Update 4"}]}}]}}]}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')"}]}]},"description":{"description_data":[{"lang":"eng","value":"A vulnerability has been identified in TIA Portal V14 (All versions), TIA Portal V15 (All versions < V15.1 Update 7), TIA Portal V16 (All versions < V16 Update 6), TIA Portal V17 (All versions < V17 Update 4). Changing the contents of a configuration file could allow an attacker to execute arbitrary code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system. No user interaction is required. At the time of advisory publication no public exploitation of this security vulnerability was known."}]},"references":{"reference_data":[{"refsource":"MISC","url":"https://cert-portal.siemens.com/productcert/pdf/ssa-629512.pdf","name":"https://cert-portal.siemens.com/productcert/pdf/ssa-629512.pdf"}]}},"nvd":{"publishedDate":"2020-01-16 16:15:00","lastModifiedDate":"2022-08-10 20:28:00","problem_types":["CWE-22"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:L/AC:L/Au:N/C:C/I:C/A:C","accessVector":"LOCAL","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE","baseScore":7.2},"severity":"HIGH","exploitabilityScore":3.9,"impactScore":10,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*","versionStartIncluding":"14","versionEndIncluding":"17","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2019","CveId":"10934","Ordinal":"149215","Title":"CVE-2019-10934","CVE":"CVE-2019-10934","Year":"2019"},"notes":[{"CveYear":"2019","CveId":"10934","Ordinal":"1","NoteData":"A vulnerability has been identified in TIA Portal V14 (All versions), TIA Portal V15 (All versions), TIA Portal V16 (All versions), TIA Portal V17 (All versions). Changing the contents of a configuration file could allow an attacker to execute arbitrary code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system. No user interaction is required. At the time of advisory publication no public exploitation of this security vulnerability was known.","Type":"Description","Title":null},{"CveYear":"2019","CveId":"10934","Ordinal":"2","NoteData":"2020-01-16","Type":"Other","Title":"Published"},{"CveYear":"2019","CveId":"10934","Ordinal":"3","NoteData":"2021-12-14","Type":"Other","Title":"Modified"}]}}}