{"api_version":"1","generated_at":"2026-07-23T12:53:25+00:00","cve":"CVE-2019-10966","urls":{"html":"https://cve.report/CVE-2019-10966","api":"https://cve.report/api/cve/CVE-2019-10966.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2019-10966","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2019-10966"},"summary":{"title":"CVE-2019-10966","description":"In GE Aestiva and Aespire versions 7100 and 7900, a vulnerability exists where serial devices are connected via an added unsecured terminal server to a TCP/IP network configuration, which could allow an attacker to remotely modify device configuration and silence alarms.","state":"PUBLIC","assigner":"ics-cert@hq.dhs.gov","published_at":"2019-07-10 18:15:00","updated_at":"2020-10-02 14:32:00"},"problem_types":["CWE-287"],"metrics":[],"references":[{"url":"http://www.securityfocus.com/bid/109102","name":"109102","refsource":"BID","tags":["Third Party Advisory","VDB Entry"],"title":"GE Aestiva and Aespire Anesthesia CVE-2019-10966 Authentication Bypass Vulnerability","mime":"text/html","httpstatus":"200","archivestatus":"0"},{"url":"https://www.us-cert.gov/ics/advisories/icsma-19-190-01","name":"https://www.us-cert.gov/ics/advisories/icsma-19-190-01","refsource":"MISC","tags":["Mitigation","Third Party Advisory","US Government Resource"],"title":"GE Aestiva and Aespire Anesthesia | CISA","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2019-10966","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2019-10966","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2019","cve_id":"10966","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"ge","cpe5":"aespire_7100","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"10966","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"ge","cpe5":"aespire_7100","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"10966","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"ge","cpe5":"aespire_7100_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"10966","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"ge","cpe5":"aespire_7100_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"10966","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"ge","cpe5":"aespire_7900","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"10966","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"ge","cpe5":"aespire_7900","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"10966","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"ge","cpe5":"aespire_7900_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"10966","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"ge","cpe5":"aespire_7900_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"10966","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"ge","cpe5":"aestiva_7100","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"10966","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"ge","cpe5":"aestiva_7100","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"10966","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"ge","cpe5":"aestiva_7100_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"10966","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"ge","cpe5":"aestiva_7100_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"10966","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"ge","cpe5":"aestiva_7900","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"10966","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"ge","cpe5":"aestiva_7900","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"10966","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"ge","cpe5":"aestiva_7900_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"10966","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"ge","cpe5":"aestiva_7900_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"data_type":"CVE","data_format":"MITRE","data_version":"4.0","CVE_data_meta":{"ID":"CVE-2019-10966","ASSIGNER":"ics-cert@hq.dhs.gov","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"vendor_name":"GE","product":{"product_data":[{"product_name":"Aestiva and Aespire","version":{"version_data":[{"version_value":"versions 7100"},{"version_value":"versions 7900"}]}}]}}]}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"IMPROPER AUTHENTICATION CWE-287"}]}]},"references":{"reference_data":[{"refsource":"BID","name":"109102","url":"http://www.securityfocus.com/bid/109102"},{"refsource":"MISC","name":"https://www.us-cert.gov/ics/advisories/icsma-19-190-01","url":"https://www.us-cert.gov/ics/advisories/icsma-19-190-01"}]},"description":{"description_data":[{"lang":"eng","value":"In GE Aestiva and Aespire versions 7100 and 7900, a vulnerability exists where serial devices are connected via an added unsecured terminal server to a TCP/IP network configuration, which could allow an attacker to remotely modify device configuration and silence alarms."}]}},"nvd":{"publishedDate":"2019-07-10 18:15:00","lastModifiedDate":"2020-10-02 14:32:00","problem_types":["CWE-287"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"LOW","availabilityImpact":"NONE","baseScore":5.3,"baseSeverity":"MEDIUM"},"exploitabilityScore":3.9,"impactScore":1.4},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:N/I:P/A:N","accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"PARTIAL","availabilityImpact":"NONE","baseScore":5},"severity":"MEDIUM","exploitabilityScore":10,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:ge:aestiva_7100_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:ge:aestiva_7100:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:ge:aestiva_7900_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:ge:aestiva_7900:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:ge:aespire_7100_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:ge:aespire_7100:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:ge:aespire_7900_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:ge:aespire_7900:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":{"CveYear":"2019","CveId":"10966","Ordinal":"149247","Title":"CVE-2019-10966","CVE":"CVE-2019-10966","Year":"2019"},"notes":[{"CveYear":"2019","CveId":"10966","Ordinal":"1","NoteData":"In GE Aestiva and Aespire versions 7100 and 7900, a vulnerability exists where serial devices are connected via an added unsecured terminal server to a TCP/IP network configuration, which could allow an attacker to remotely modify device configuration and silence alarms.","Type":"Description","Title":null},{"CveYear":"2019","CveId":"10966","Ordinal":"2","NoteData":"2019-07-10","Type":"Other","Title":"Published"},{"CveYear":"2019","CveId":"10966","Ordinal":"3","NoteData":"2019-07-10","Type":"Other","Title":"Modified"}]}}}