{"api_version":"1","generated_at":"2026-06-07T15:17:09+00:00","cve":"CVE-2019-12503","urls":{"html":"https://cve.report/CVE-2019-12503","api":"https://cve.report/api/cve/CVE-2019-12503.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2019-12503","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2019-12503"},"summary":{"title":"CVE-2019-12503","description":"Due to unencrypted and unauthenticated data communication, the wireless barcode scanner Inateck BCST-60 is prone to keystroke injection attacks. Thus, an attacker is able to send arbitrary keystrokes to a victim's computer system, e.g., to install malware when the target system is unattended. In this way, an attacker can remotely take control over the victim's computer that is operated with an affected receiver of this device.","state":"PUBLIC","assigner":"cve@mitre.org","published_at":"2019-12-02 17:15:00","updated_at":"2020-08-24 17:37:00"},"problem_types":["CWE-306","CWE-319"],"metrics":[],"references":[{"url":"http://seclists.org/fulldisclosure/2019/Nov/30","name":"20191129 [SYSS-2019-027]: Inateck BCST-60 Barcode Scanner - Keystroke Injection Vulnerability (CVE-2019-12503)","refsource":"FULLDISC","tags":["Mailing List","Third Party Advisory"],"title":"Full Disclosure: [SYSS-2019-027]: Inateck BCST-60 Barcode Scanner - Keystroke Injection Vulnerability (CVE-2019-12503)","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"http://packetstormsecurity.com/files/155503/Inateck-BCST-60-Barcode-Scanner-Keystroke-Injection.html","name":"http://packetstormsecurity.com/files/155503/Inateck-BCST-60-Barcode-Scanner-Keystroke-Injection.html","refsource":"MISC","tags":["Third Party Advisory","VDB Entry"],"title":"Inateck BCST-60 Barcode Scanner Keystroke Injection ≈ Packet Storm","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2019-027.txt","name":"https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2019-027.txt","refsource":"MISC","tags":["Broken Link","Third Party Advisory"],"title":"","mime":"text/plain","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2019-12503","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2019-12503","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2019","cve_id":"12503","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"inateck","cpe5":"bcst-60","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"12503","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"inateck","cpe5":"bcst-60","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"12503","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"inateck","cpe5":"bcst-60_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"12503","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"inateck","cpe5":"bcst-60_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"cve@mitre.org","ID":"CVE-2019-12503","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"n/a","version":{"version_data":[{"version_value":"n/a"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Due to unencrypted and unauthenticated data communication, the wireless barcode scanner Inateck BCST-60 is prone to keystroke injection attacks. Thus, an attacker is able to send arbitrary keystrokes to a victim's computer system, e.g., to install malware when the target system is unattended. In this way, an attacker can remotely take control over the victim's computer that is operated with an affected receiver of this device."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"n/a"}]}]},"references":{"reference_data":[{"url":"https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2019-027.txt","refsource":"MISC","name":"https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2019-027.txt"},{"refsource":"FULLDISC","name":"20191129 [SYSS-2019-027]: Inateck BCST-60 Barcode Scanner - Keystroke Injection Vulnerability (CVE-2019-12503)","url":"http://seclists.org/fulldisclosure/2019/Nov/30"},{"refsource":"MISC","name":"http://packetstormsecurity.com/files/155503/Inateck-BCST-60-Barcode-Scanner-Keystroke-Injection.html","url":"http://packetstormsecurity.com/files/155503/Inateck-BCST-60-Barcode-Scanner-Keystroke-Injection.html"}]}},"nvd":{"publishedDate":"2019-12-02 17:15:00","lastModifiedDate":"2020-08-24 17:37:00","problem_types":["CWE-306","CWE-319"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":9.8,"baseSeverity":"CRITICAL"},"exploitabilityScore":3.9,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:C/I:C/A:C","accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE","baseScore":10},"severity":"HIGH","exploitabilityScore":10,"impactScore":10,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:inateck:bcst-60_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:inateck:bcst-60:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":{"CveYear":"2019","CveId":"12503","Ordinal":"150841","Title":"CVE-2019-12503","CVE":"CVE-2019-12503","Year":"2019"},"notes":[{"CveYear":"2019","CveId":"12503","Ordinal":"1","NoteData":"Due to unencrypted and unauthenticated data communication, the wireless barcode scanner Inateck BCST-60 is prone to keystroke injection attacks. Thus, an attacker is able to send arbitrary keystrokes to a victim's computer system, e.g., to install malware when the target system is unattended. In this way, an attacker can remotely take control over the victim's computer that is operated with an affected receiver of this device.","Type":"Description","Title":null},{"CveYear":"2019","CveId":"12503","Ordinal":"2","NoteData":"2019-12-02","Type":"Other","Title":"Published"},{"CveYear":"2019","CveId":"12503","Ordinal":"3","NoteData":"2019-12-02","Type":"Other","Title":"Modified"}]}}}