{"api_version":"1","generated_at":"2026-04-23T06:19:19+00:00","cve":"CVE-2019-13537","urls":{"html":"https://cve.report/CVE-2019-13537","api":"https://cve.report/api/cve/CVE-2019-13537.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2019-13537","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2019-13537"},"summary":{"title":"CVE-2019-13537","description":"The IEC870IP driver for AVEVA’s Vijeo Citect and Citect SCADA and Schneider Electric’s Power SCADA Operation has a buffer overflow vulnerability that could result in a server-side crash.","state":"PUBLIC","assigner":"ics-cert@hq.dhs.gov","published_at":"2020-01-14 19:15:00","updated_at":"2020-02-10 21:50:00"},"problem_types":["CWE-787"],"metrics":[],"references":[{"url":"https://www.us-cert.gov/ics/advisories/icsa-19-290-01","name":"https://www.us-cert.gov/ics/advisories/icsa-19-290-01","refsource":"MISC","tags":["Third Party Advisory","US Government Resource"],"title":"AVEVA Vijeo Citect and Citect SCADA (Update A) | CISA","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://sw.aveva.com/hubfs/assets-2018/pdf/security-bulletin/SecurityBulletin_LFSec139.pdf","name":"https://sw.aveva.com/hubfs/assets-2018/pdf/security-bulletin/SecurityBulletin_LFSec139.pdf","refsource":"CONFIRM","tags":["Vendor Advisory"],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2019-13537","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2019-13537","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2019","cve_id":"13537","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"aveva","cpe5":"iec870ip","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"13537","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"aveva","cpe5":"iec870ip","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"13537","vulnerable":"1","versionEndIncluding":"4.14.02","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"aveva","cpe5":"iec870ip_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"data_type":"CVE","data_format":"MITRE","data_version":"4.0","CVE_data_meta":{"ID":"CVE-2019-13537","ASSIGNER":"ics-cert@hq.dhs.gov","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"vendor_name":"AVEVA","product":{"product_data":[{"product_name":"Vijeo Citect and Citect SCADA","version":{"version_data":[{"version_value":"IEC870IP driver v4.14.02 and prior"}]}}]}}]}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"STACK-BASED BUFFER OVERFLOW CWE-121"}]}]},"references":{"reference_data":[{"refsource":"MISC","name":"https://www.us-cert.gov/ics/advisories/icsa-19-290-01","url":"https://www.us-cert.gov/ics/advisories/icsa-19-290-01"},{"refsource":"CONFIRM","name":"https://sw.aveva.com/hubfs/assets-2018/pdf/security-bulletin/SecurityBulletin_LFSec139.pdf","url":"https://sw.aveva.com/hubfs/assets-2018/pdf/security-bulletin/SecurityBulletin_LFSec139.pdf"}]},"description":{"description_data":[{"lang":"eng","value":"The IEC870IP driver for AVEVA’s Vijeo Citect and Citect SCADA and Schneider Electric’s Power SCADA Operation has a buffer overflow vulnerability that could result in a server-side crash."}]}},"nvd":{"publishedDate":"2020-01-14 19:15:00","lastModifiedDate":"2020-02-10 21:50:00","problem_types":["CWE-787"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH","baseScore":7.5,"baseSeverity":"HIGH"},"exploitabilityScore":3.9,"impactScore":3.6},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:N/I:N/A:P","accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"PARTIAL","baseScore":5},"severity":"MEDIUM","exploitabilityScore":10,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:aveva:iec870ip_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"4.14.02","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:aveva:iec870ip:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":{"CveYear":"2019","CveId":"13537","Ordinal":"151897","Title":"CVE-2019-13537","CVE":"CVE-2019-13537","Year":"2019"},"notes":[{"CveYear":"2019","CveId":"13537","Ordinal":"1","NoteData":"The IEC870IP driver for AVEVA’s Vijeo Citect and Citect SCADA and Schneider Electric’s Power SCADA Operation has a buffer overflow vulnerability that could result in a server-side crash.","Type":"Description","Title":null},{"CveYear":"2019","CveId":"13537","Ordinal":"2","NoteData":"2020-01-14","Type":"Other","Title":"Published"},{"CveYear":"2019","CveId":"13537","Ordinal":"3","NoteData":"2020-01-14","Type":"Other","Title":"Modified"}]}}}