{"api_version":"1","generated_at":"2026-07-23T14:52:36+00:00","cve":"CVE-2019-13922","urls":{"html":"https://cve.report/CVE-2019-13922","api":"https://cve.report/api/cve/CVE-2019-13922.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2019-13922","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2019-13922"},"summary":{"title":"CVE-2019-13922","description":"A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0 SP1). An attacker with administrative privileges can obtain the hash of a connected device's password. The security vulnerability could be exploited by an attacker with network access to the SINEMA Remote Connect Server and administrative privileges. At the time of advisory publication no public exploitation of this security vulnerability was known.","state":"PUBLIC","assigner":"productcert@siemens.com","published_at":"2019-09-13 17:15:00","updated_at":"2021-10-28 16:45:00"},"problem_types":["CWE-311"],"metrics":[],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-884497.pdf","name":"https://cert-portal.siemens.com/productcert/pdf/ssa-884497.pdf","refsource":"MISC","tags":["Patch","Vendor Advisory"],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2019-13922","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2019-13922","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2019","cve_id":"13922","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"sinema_remote_connect_server","cpe6":"2.0","cpe7":"hf1","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"13922","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"sinema_remote_connect_server","cpe6":"2.0","cpe7":"hf1","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"13922","vulnerable":"1","versionEndIncluding":"2.0","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"sinema_remote_connect_server","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"productcert@siemens.com","ID":"CVE-2019-13922","STATE":"PUBLIC"},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","affects":{"vendor":{"vendor_data":[{"vendor_name":"Siemens AG","product":{"product_data":[{"product_name":"SINEMA Remote Connect Server","version":{"version_data":[{"version_value":"All versions < V2.0 SP1"}]}}]}}]}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-311: Missing Encryption of Sensitive Data"}]}]},"references":{"reference_data":[{"refsource":"MISC","url":"https://cert-portal.siemens.com/productcert/pdf/ssa-884497.pdf","name":"https://cert-portal.siemens.com/productcert/pdf/ssa-884497.pdf"}]},"description":{"description_data":[{"lang":"eng","value":"A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0 SP1). An attacker with administrative privileges can obtain the hash of a connected device's password. The security vulnerability could be exploited by an attacker with network access to the SINEMA Remote Connect Server and administrative privileges. At the time of advisory publication no public exploitation of this security vulnerability was known."}]}},"nvd":{"publishedDate":"2019-09-13 17:15:00","lastModifiedDate":"2021-10-28 16:45:00","problem_types":["CWE-311"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"NONE","availabilityImpact":"NONE","baseScore":2.7,"baseSeverity":"LOW"},"exploitabilityScore":1.2,"impactScore":1.4},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:L/Au:S/C:P/I:N/A:N","accessVector":"NETWORK","accessComplexity":"LOW","authentication":"SINGLE","confidentialityImpact":"PARTIAL","integrityImpact":"NONE","availabilityImpact":"NONE","baseScore":4},"severity":"MEDIUM","exploitabilityScore":8,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:sinema_remote_connect_server:2.0:hf1:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:sinema_remote_connect_server:*:*:*:*:*:*:*:*","versionEndIncluding":"2.0","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2019","CveId":"13922","Ordinal":"152779","Title":"CVE-2019-13922","CVE":"CVE-2019-13922","Year":"2019"},"notes":[{"CveYear":"2019","CveId":"13922","Ordinal":"1","NoteData":"A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0 SP1). An attacker with administrative privileges can obtain the hash of a connected device's password. The security vulnerability could be exploited by an attacker with network access to the SINEMA Remote Connect Server and administrative privileges. At the time of advisory publication no public exploitation of this security vulnerability was known.","Type":"Description","Title":null},{"CveYear":"2019","CveId":"13922","Ordinal":"2","NoteData":"2019-09-13","Type":"Other","Title":"Published"},{"CveYear":"2019","CveId":"13922","Ordinal":"3","NoteData":"2019-09-13","Type":"Other","Title":"Modified"}]}}}