{"api_version":"1","generated_at":"2026-04-23T05:57:44+00:00","cve":"CVE-2019-18255","urls":{"html":"https://cve.report/CVE-2019-18255","api":"https://cve.report/api/cve/CVE-2019-18255.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2019-18255","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2019-18255"},"summary":{"title":"CVE-2019-18255","description":"HMI/SCADA iFIX (Versions 6.1 and prior) allows a local authenticated user to modify system-wide iFIX configurations through section objects. This may allow privilege escalation.","state":"PUBLIC","assigner":"ics-cert@hq.dhs.gov","published_at":"2021-02-18 15:15:00","updated_at":"2021-02-24 19:12:00"},"problem_types":["CWE-732"],"metrics":[],"references":[{"url":"https://us-cert.cisa.gov/ics/advisories/icsa-21-040-01","name":"https://us-cert.cisa.gov/ics/advisories/icsa-21-040-01","refsource":"MISC","tags":["Third Party Advisory","US Government Resource"],"title":"GE Digital HMI/SCADA iFIX | CISA","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2019-18255","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2019-18255","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2019","cve_id":"18255","vulnerable":"1","versionEndIncluding":"6.1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"ge","cpe5":"ifix","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[{"cve":"CVE-2019-18255","qid":"590558","title":"GE Digital HMI/SCADA iFIX Multiple Vulnerabilities (ICSA-21-040-01)"}]},"source_records":{"cve_program":{"data_type":"CVE","data_format":"MITRE","data_version":"4.0","CVE_data_meta":{"ID":"CVE-2019-18255","ASSIGNER":"ics-cert@hq.dhs.gov","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"vendor_name":"n/a","product":{"product_data":[{"product_name":"HMI/SCADA iFIX","version":{"version_data":[{"version_value":"Versions 6.1 and prior"}]}}]}}]}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"INCORRECT PERMISSION ASSIGNMENT FOR CRITICAL RESOURCE CWE-732"}]}]},"references":{"reference_data":[{"refsource":"MISC","name":"https://us-cert.cisa.gov/ics/advisories/icsa-21-040-01","url":"https://us-cert.cisa.gov/ics/advisories/icsa-21-040-01"}]},"description":{"description_data":[{"lang":"eng","value":"HMI/SCADA iFIX (Versions 6.1 and prior) allows a local authenticated user to modify system-wide iFIX configurations through section objects. This may allow privilege escalation."}]}},"nvd":{"publishedDate":"2021-02-18 15:15:00","lastModifiedDate":"2021-02-24 19:12:00","problem_types":["CWE-732"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"HIGH","availabilityImpact":"NONE","baseScore":5.5,"baseSeverity":"MEDIUM"},"exploitabilityScore":1.8,"impactScore":3.6},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:L/AC:L/Au:N/C:N/I:P/A:N","accessVector":"LOCAL","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"PARTIAL","availabilityImpact":"NONE","baseScore":2.1},"severity":"LOW","exploitabilityScore":3.9,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:ge:ifix:*:*:*:*:*:*:*:*","versionEndIncluding":"6.1","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2019","CveId":"18255","Ordinal":"158629","Title":"CVE-2019-18255","CVE":"CVE-2019-18255","Year":"2019"},"notes":[{"CveYear":"2019","CveId":"18255","Ordinal":"1","NoteData":"HMI/SCADA iFIX (Versions 6.1 and prior) allows a local authenticated user to modify system-wide iFIX configurations through section objects. This may allow privilege escalation.","Type":"Description","Title":null},{"CveYear":"2019","CveId":"18255","Ordinal":"2","NoteData":"2021-02-18","Type":"Other","Title":"Published"},{"CveYear":"2019","CveId":"18255","Ordinal":"3","NoteData":"2021-02-18","Type":"Other","Title":"Modified"}]}}}