{"api_version":"1","generated_at":"2026-07-23T11:11:44+00:00","cve":"CVE-2019-18256","urls":{"html":"https://cve.report/CVE-2019-18256","api":"https://cve.report/api/cve/CVE-2019-18256.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2019-18256","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2019-18256"},"summary":{"title":"CVE-2019-18256","description":"BIOTRONIK CardioMessenger II, The affected products use individual per-device credentials that are stored in a recoverable format. An attacker with physical access to the CardioMessenger can use these credentials for network authentication and decryption of local data in transit.","state":"PUBLIC","assigner":"ics-cert@hq.dhs.gov","published_at":"2020-06-29 14:15:00","updated_at":"2021-10-29 19:58:00"},"problem_types":["CWE-522"],"metrics":[],"references":[{"url":"https://www.us-cert.gov/ics/advisories/icsma-20-170-05","name":"https://www.us-cert.gov/ics/advisories/icsma-20-170-05","refsource":"MISC","tags":["Third Party Advisory","US Government Resource"],"title":"BIOTRONIK CardioMessenger II | CISA","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2019-18256","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2019-18256","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2019","cve_id":"18256","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"biotronik","cpe5":"cardiomessenger_ii-s_gsm","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"18256","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"biotronik","cpe5":"cardiomessenger_ii-s_gsm","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"18256","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"biotronik","cpe5":"cardiomessenger_ii-s_gsm_firmware","cpe6":"2.20","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"18256","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"biotronik","cpe5":"cardiomessenger_ii-s_gsm_firmware","cpe6":"2.20","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"18256","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"biotronik","cpe5":"cardiomessenger_ii-s_t-line","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"18256","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"biotronik","cpe5":"cardiomessenger_ii-s_t-line","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"18256","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"biotronik","cpe5":"cardiomessenger_ii-s_t-line_firmware","cpe6":"2.20","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"18256","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"biotronik","cpe5":"cardiomessenger_ii-s_t-line_firmware","cpe6":"2.20","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"data_type":"CVE","data_format":"MITRE","data_version":"4.0","CVE_data_meta":{"ID":"CVE-2019-18256","ASSIGNER":"ics-cert@hq.dhs.gov","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"vendor_name":"n/a","product":{"product_data":[{"product_name":"BIOTRONIK CardioMessenger II-S T-Line, CardioMessenger II-S GSM","version":{"version_data":[{"version_value":"CardioMessenger II-S T-Line T4APP 2.20, CardioMessenger II-S GSM T4APP 2.20"}]}}]}}]}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"STORING PASSWORDS IN A RECOVERABLE FORMAT CWE-257"}]}]},"references":{"reference_data":[{"refsource":"MISC","name":"https://www.us-cert.gov/ics/advisories/icsma-20-170-05","url":"https://www.us-cert.gov/ics/advisories/icsma-20-170-05"}]},"description":{"description_data":[{"lang":"eng","value":"BIOTRONIK CardioMessenger II, The affected products use individual per-device credentials that are stored in a recoverable format. An attacker with physical access to the CardioMessenger can use these credentials for network authentication and decryption of local data in transit."}]}},"nvd":{"publishedDate":"2020-06-29 14:15:00","lastModifiedDate":"2021-10-29 19:58:00","problem_types":["CWE-522"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","attackVector":"PHYSICAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE","baseScore":4.6,"baseSeverity":"MEDIUM"},"exploitabilityScore":0.9,"impactScore":3.6},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:L/AC:L/Au:N/C:P/I:N/A:N","accessVector":"LOCAL","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"NONE","availabilityImpact":"NONE","baseScore":2.1},"severity":"LOW","exploitabilityScore":3.9,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:biotronik:cardiomessenger_ii-s_gsm_firmware:2.20:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:biotronik:cardiomessenger_ii-s_gsm:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:biotronik:cardiomessenger_ii-s_t-line_firmware:2.20:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:biotronik:cardiomessenger_ii-s_t-line:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":{"CveYear":"2019","CveId":"18256","Ordinal":"158630","Title":"CVE-2019-18256","CVE":"CVE-2019-18256","Year":"2019"},"notes":[{"CveYear":"2019","CveId":"18256","Ordinal":"1","NoteData":"BIOTRONIK CardioMessenger II, The affected products use individual per-device credentials that are stored in a recoverable format. An attacker with physical access to the CardioMessenger can use these credentials for network authentication and decryption of local data in transit.","Type":"Description","Title":null},{"CveYear":"2019","CveId":"18256","Ordinal":"2","NoteData":"2020-06-29","Type":"Other","Title":"Published"},{"CveYear":"2019","CveId":"18256","Ordinal":"3","NoteData":"2020-06-29","Type":"Other","Title":"Modified"}]}}}