{"api_version":"1","generated_at":"2026-07-24T01:58:56+00:00","cve":"CVE-2019-19279","urls":{"html":"https://cve.report/CVE-2019-19279","api":"https://cve.report/api/cve/CVE-2019-19279.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2019-19279","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2019-19279"},"summary":{"title":"CVE-2019-19279","description":"A vulnerability has been identified in SIPROTEC 4 and SIPROTEC Compact relays equipped with EN100 Ethernet communication modules (All versions). Specially crafted packets sent to port 50000/UDP of the EN100 Ethernet communication modules could cause a Denial-of-Service of the affected device. A manual reboot is required to recover the service of the device. At the time of advisory publication no public exploitation of this security vulnerability was known to Siemens.","state":"PUBLIC","assigner":"productcert@siemens.com","published_at":"2020-03-10 20:15:00","updated_at":"2020-03-13 19:49:00"},"problem_types":["CWE-20"],"metrics":[],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-974843.pdf","name":"https://cert-portal.siemens.com/productcert/pdf/ssa-974843.pdf","refsource":"MISC","tags":["Vendor Advisory"],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2019-19279","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2019-19279","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2019","cve_id":"19279","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"siprotec_4","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"19279","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"siprotec_4","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"19279","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"siprotec_compact","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"19279","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"siprotec_compact","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"productcert@siemens.com","ID":"CVE-2019-19279","STATE":"PUBLIC"},"data_format":"MITRE","data_version":"4.0","data_type":"CVE","affects":{"vendor":{"vendor_data":[{"vendor_name":"Siemens AG","product":{"product_data":[{"product_name":"SIPROTEC 4 and SIPROTEC Compact relays equipped with EN100 Ethernet communication modules","version":{"version_data":[{"version_value":"All versions"}]}}]}}]}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-20: Improper Input Validation"}]}]},"description":{"description_data":[{"lang":"eng","value":"A vulnerability has been identified in SIPROTEC 4 and SIPROTEC Compact relays equipped with EN100 Ethernet communication modules (All versions). Specially crafted packets sent to port 50000/UDP of the EN100 Ethernet communication modules could cause a Denial-of-Service of the affected device. A manual reboot is required to recover the service of the device. At the time of advisory publication no public exploitation of this security vulnerability was known to Siemens."}]},"references":{"reference_data":[{"refsource":"MISC","url":"https://cert-portal.siemens.com/productcert/pdf/ssa-974843.pdf","name":"https://cert-portal.siemens.com/productcert/pdf/ssa-974843.pdf"}]}},"nvd":{"publishedDate":"2020-03-10 20:15:00","lastModifiedDate":"2020-03-13 19:49:00","problem_types":["CWE-20"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH","baseScore":7.5,"baseSeverity":"HIGH"},"exploitabilityScore":3.9,"impactScore":3.6},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:N/I:N/A:C","accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"COMPLETE","baseScore":7.8},"severity":"HIGH","exploitabilityScore":10,"impactScore":6.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:siprotec_4:*:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:siprotec_compact:*:*:*:*:*:*:*:*","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2019","CveId":"19279","Ordinal":"160848","Title":"CVE-2019-19279","CVE":"CVE-2019-19279","Year":"2019"},"notes":[{"CveYear":"2019","CveId":"19279","Ordinal":"1","NoteData":"A vulnerability has been identified in SIPROTEC 4 and SIPROTEC Compact relays equipped with EN100 Ethernet communication modules (All versions). Specially crafted packets sent to port 50000/UDP of the EN100 Ethernet communication modules could cause a Denial-of-Service of the affected device. A manual reboot is required to recover the service of the device. At the time of advisory publication no public exploitation of this security vulnerability was known to Siemens.","Type":"Description","Title":null},{"CveYear":"2019","CveId":"19279","Ordinal":"2","NoteData":"2020-03-10","Type":"Other","Title":"Published"},{"CveYear":"2019","CveId":"19279","Ordinal":"3","NoteData":"2020-03-10","Type":"Other","Title":"Modified"}]}}}