{"api_version":"1","generated_at":"2026-07-23T21:09:56+00:00","cve":"CVE-2019-3753","urls":{"html":"https://cve.report/CVE-2019-3753","api":"https://cve.report/api/cve/CVE-2019-3753.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2019-3753","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2019-3753"},"summary":{"title":"CVE-2019-3753","description":"Dell EMC PowerConnect 8024, 7000, M6348, M6220, M8024 and M8024-K running firmware versions prior to 5.1.15.2 contain a plain-text password storage vulnerability. TACACS\\Radius credentials are stored in plain text in the system settings menu. An authenticated malicious user with access to the system settings menu may obtain the exposed password to use it in further attacks.","state":"PUBLIC","assigner":"secure@dell.com","published_at":"2019-08-20 19:15:00","updated_at":"2020-10-16 14:49:00"},"problem_types":["CWE-522"],"metrics":[],"references":[{"url":"https://www.dell.com/support/article/sln318359/","name":"https://www.dell.com/support/article/sln318359/","refsource":"CONFIRM","tags":["Vendor Advisory"],"title":"DSA-2019-124: Dell EMC PowerConnect Security Vulnerability | Dell US","mime":"text/html","httpstatus":"403","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2019-3753","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2019-3753","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2019","cve_id":"3753","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"dell","cpe5":"emc_powerconnect_7000","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"3753","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"dell","cpe5":"emc_powerconnect_7000","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"3753","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"dell","cpe5":"emc_powerconnect_7000_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"3753","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"dell","cpe5":"emc_powerconnect_7000_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"3753","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"dell","cpe5":"emc_powerconnect_8024","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"3753","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"dell","cpe5":"emc_powerconnect_8024","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"3753","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"dell","cpe5":"emc_powerconnect_8024_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"3753","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"dell","cpe5":"emc_powerconnect_8024_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"3753","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"dell","cpe5":"emc_powerconnect_m6220","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"3753","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"dell","cpe5":"emc_powerconnect_m6220","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"3753","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"dell","cpe5":"emc_powerconnect_m6220_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"3753","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"dell","cpe5":"emc_powerconnect_m6220_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"3753","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"dell","cpe5":"emc_powerconnect_m6348","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"3753","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"dell","cpe5":"emc_powerconnect_m6348","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"3753","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"dell","cpe5":"emc_powerconnect_m6348_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"3753","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"dell","cpe5":"emc_powerconnect_m6348_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"3753","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"dell","cpe5":"emc_powerconnect_m8024","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"3753","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"dell","cpe5":"emc_powerconnect_m8024","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"3753","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"dell","cpe5":"emc_powerconnect_m8024-k","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"3753","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"dell","cpe5":"emc_powerconnect_m8024-k","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"3753","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"dell","cpe5":"emc_powerconnect_m8024-k_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"3753","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"dell","cpe5":"emc_powerconnect_m8024-k_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"3753","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"dell","cpe5":"emc_powerconnect_m8024_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"3753","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"dell","cpe5":"emc_powerconnect_m8024_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"secure@dell.com","DATE_PUBLIC":"2019-08-16T04:00:00.000Z","ID":"CVE-2019-3753","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"PowerConnect 8024","version":{"version_data":[{"version_affected":"<","version_value":"5.1.15.2"}]}},{"product_name":"PowerConnect 7000","version":{"version_data":[{"version_affected":"<","version_value":"5.1.15.2"}]}},{"product_name":"PowerConnect M6348","version":{"version_data":[{"version_affected":"<","version_value":"5.1.15.2"}]}},{"product_name":"PowerConnect M6220","version":{"version_data":[{"version_affected":"<","version_value":"5.1.15.2"}]}},{"product_name":"PowerConnect M8024 ","version":{"version_data":[{"version_affected":"<","version_value":"5.1.15.2"}]}},{"product_name":"PowerConnect  M8024-K","version":{"version_data":[{"version_affected":"<","version_value":"5.1.15.2"}]}}]},"vendor_name":"Dell EMC"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Dell EMC PowerConnect 8024, 7000, M6348, M6220, M8024 and M8024-K running firmware versions prior to 5.1.15.2 contain a plain-text password storage vulnerability. TACACS\\Radius credentials are stored in plain text in the system settings menu. An authenticated malicious user with access to the system settings menu may obtain the exposed password to use it in further attacks."}]},"generator":{"engine":"Vulnogram 0.0.7"},"impact":{"cvss":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":7.2,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"HIGH","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","version":"3.0"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-312 Cleartext Storage of Sensitive Information"}]}]},"references":{"reference_data":[{"refsource":"CONFIRM","name":"https://www.dell.com/support/article/sln318359/","url":"https://www.dell.com/support/article/sln318359/"}]},"source":{"discovery":"UNKNOWN"}},"nvd":{"publishedDate":"2019-08-20 19:15:00","lastModifiedDate":"2020-10-16 14:49:00","problem_types":["CWE-522"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE","baseScore":6.5,"baseSeverity":"MEDIUM"},"exploitabilityScore":2.8,"impactScore":3.6},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:L/Au:S/C:P/I:N/A:N","accessVector":"NETWORK","accessComplexity":"LOW","authentication":"SINGLE","confidentialityImpact":"PARTIAL","integrityImpact":"NONE","availabilityImpact":"NONE","baseScore":4},"severity":"MEDIUM","exploitabilityScore":8,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:dell:emc_powerconnect_8024_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"5.1.15.2","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:dell:emc_powerconnect_8024:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:dell:emc_powerconnect_7000_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"5.1.15.2","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:dell:emc_powerconnect_7000:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:dell:emc_powerconnect_m6348_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"5.1.15.2","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:dell:emc_powerconnect_m6348:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:dell:emc_powerconnect_m6220_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"5.1.15.2","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:dell:emc_powerconnect_m6220:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:dell:emc_powerconnect_m8024_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"5.1.15.2","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:dell:emc_powerconnect_m8024:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:dell:emc_powerconnect_m8024-k_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"5.1.15.2","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:dell:emc_powerconnect_m8024-k:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":{"CveYear":"2019","CveId":"3753","Ordinal":"141362","Title":"CVE-2019-3753","CVE":"CVE-2019-3753","Year":"2019"},"notes":[{"CveYear":"2019","CveId":"3753","Ordinal":"1","NoteData":"Dell EMC PowerConnect 8024, 7000, M6348, M6220, M8024 and M8024-K running firmware versions prior to 5.1.15.2 contain a plain-text password storage vulnerability. TACACS\\Radius credentials are stored in plain text in the system settings menu. An authenticated malicious user with access to the system settings menu may obtain the exposed password to use it in further attacks.","Type":"Description","Title":null},{"CveYear":"2019","CveId":"3753","Ordinal":"2","NoteData":"2019-08-20","Type":"Other","Title":"Published"},{"CveYear":"2019","CveId":"3753","Ordinal":"3","NoteData":"2019-08-20","Type":"Other","Title":"Modified"}]}}}