{"api_version":"1","generated_at":"2026-05-13T19:41:23+00:00","cve":"CVE-2019-3754","urls":{"html":"https://cve.report/CVE-2019-3754","api":"https://cve.report/api/cve/CVE-2019-3754.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2019-3754","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2019-3754"},"summary":{"title":"CVE-2019-3754","description":"Dell EMC Unity Operating Environment versions prior to 5.0.0.0.5.116, Dell EMC UnityVSA versions prior to 5.0.0.0.5.116 and Dell EMC VNXe3200 versions prior to 3.1.10.9946299 contain a reflected cross-site scripting vulnerability on the cas/logout page. A remote unauthenticated attacker could potentially exploit this vulnerability by tricking a victim application user to supply malicious HTML or Java Script code to Unisphere, which is then reflected back to the victim and executed by the web browser.","state":"PUBLIC","assigner":"secure@dell.com","published_at":"2019-09-03 17:15:00","updated_at":"2019-10-09 23:49:00"},"problem_types":["CWE-79"],"metrics":[],"references":[{"url":"https://www.dell.com/support/security/en-us/details/536796/DSA-2019-125-Dell-EMC-Unity-and-VNXe3200-Family-Reflected-Cross-Site-Scripting-Vulnerability","name":"https://www.dell.com/support/security/en-us/details/536796/DSA-2019-125-Dell-EMC-Unity-and-VNXe3200-Family-Reflected-Cross-Site-Scripting-Vulnerability","refsource":"CONFIRM","tags":["Vendor Advisory"],"title":"DSA-2019-125: Dell EMC Unity and VNXe3200 Family Reflected Cross-Site Scripting Vulnerability | Dell US","mime":"text/html","httpstatus":"403","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2019-3754","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2019-3754","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2019","cve_id":"3754","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"dell","cpe5":"emc_unityvsa_operating_environment","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"3754","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"dell","cpe5":"emc_unityvsa_operating_environment","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"3754","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"dell","cpe5":"emc_unity_operating_environment","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"3754","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"dell","cpe5":"emc_unity_operating_environment","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"3754","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"dell","cpe5":"emc_vnxe3200","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"3754","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"dell","cpe5":"emc_vnxe3200","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"3754","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"dell","cpe5":"emc_vnxe3200_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"3754","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"dell","cpe5":"emc_vnxe3200_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"secure@dell.com","DATE_PUBLIC":"2019-08-27T16:00:00.000Z","ID":"CVE-2019-3754","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":" Unity Operating Environment","version":{"version_data":[{"version_affected":"<","version_value":"5.0.0.0.5.116"}]}},{"product_name":"UnityVSA Operating Environment","version":{"version_data":[{"version_affected":"<","version_value":"5.0.0.0.5.116"}]}},{"product_name":"VNXe3200 Operating Environment","version":{"version_data":[{"version_affected":"<","version_value":"3.1.10.9946299"}]}}]},"vendor_name":"DELL EMC"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Dell EMC Unity Operating Environment versions prior to 5.0.0.0.5.116, Dell EMC UnityVSA versions prior to 5.0.0.0.5.116 and Dell EMC VNXe3200 versions prior to 3.1.10.9946299 contain a reflected cross-site scripting vulnerability on the cas/logout page. A remote unauthenticated attacker could potentially exploit this vulnerability by tricking a victim application user to supply malicious HTML or Java Script code to Unisphere, which is then reflected back to the victim and executed by the web browser."}]},"generator":{"engine":"Vulnogram 0.0.7"},"impact":{"cvss":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":4.7,"baseSeverity":"MEDIUM","confidentialityImpact":"LOW","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"CHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:N/A:N","version":"3.0"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-79 Cross-site Scripting (XSS)"}]}]},"references":{"reference_data":[{"refsource":"CONFIRM","name":"https://www.dell.com/support/security/en-us/details/536796/DSA-2019-125-Dell-EMC-Unity-and-VNXe3200-Family-Reflected-Cross-Site-Scripting-Vulnerability","url":"https://www.dell.com/support/security/en-us/details/536796/DSA-2019-125-Dell-EMC-Unity-and-VNXe3200-Family-Reflected-Cross-Site-Scripting-Vulnerability"}]},"source":{"discovery":"UNKNOWN"}},"nvd":{"publishedDate":"2019-09-03 17:15:00","lastModifiedDate":"2019-10-09 23:49:00","problem_types":["CWE-79"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"CHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"NONE","baseScore":6.1,"baseSeverity":"MEDIUM"},"exploitabilityScore":2.8,"impactScore":2.7},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:N/I:P/A:N","accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"PARTIAL","availabilityImpact":"NONE","baseScore":4.3},"severity":"MEDIUM","exploitabilityScore":8.6,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:dell:emc_unity_operating_environment:*:*:*:*:*:*:*:*","versionEndExcluding":"5.0.0.0.5.116","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:dell:emc_unityvsa_operating_environment:*:*:*:*:*:*:*:*","versionEndExcluding":"5.0.0.0.5.116","cpe_name":[]}]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:dell:emc_vnxe3200_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"3.1.10.9946299","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:dell:emc_vnxe3200:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":{"CveYear":"2019","CveId":"3754","Ordinal":"141363","Title":"CVE-2019-3754","CVE":"CVE-2019-3754","Year":"2019"},"notes":[{"CveYear":"2019","CveId":"3754","Ordinal":"1","NoteData":"Dell EMC Unity Operating Environment versions prior to 5.0.0.0.5.116, Dell EMC UnityVSA versions prior to 5.0.0.0.5.116 and Dell EMC VNXe3200 versions prior to 3.1.10.9946299 contain a reflected cross-site scripting vulnerability on the cas/logout page. A remote unauthenticated attacker could potentially exploit this vulnerability by tricking a victim application user to supply malicious HTML or Java Script code to Unisphere, which is then reflected back to the victim and executed by the web browser.","Type":"Description","Title":null},{"CveYear":"2019","CveId":"3754","Ordinal":"2","NoteData":"2019-09-03","Type":"Other","Title":"Published"},{"CveYear":"2019","CveId":"3754","Ordinal":"3","NoteData":"2019-09-03","Type":"Other","Title":"Modified"}]}}}