{"api_version":"1","generated_at":"2026-07-23T21:10:07+00:00","cve":"CVE-2019-5035","urls":{"html":"https://cve.report/CVE-2019-5035","api":"https://cve.report/api/cve/CVE-2019-5035.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2019-5035","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2019-5035"},"summary":{"title":"CVE-2019-5035","description":"An exploitable information disclosure vulnerability exists in the Weave PASE pairing functionality of the Nest Cam IQ Indoor, version 4620002. A set of specially crafted weave packets can brute force a pairing code, resulting in greater Weave access and potentially full device control. An attacker can send specially crafted packets to trigger this vulnerability.","state":"PUBLIC","assigner":"talos-cna@cisco.com","published_at":"2019-08-20 22:15:00","updated_at":"2022-06-27 17:28:00"},"problem_types":["CWE-327"],"metrics":[],"references":[{"url":"https://talosintelligence.com/vulnerability_reports/TALOS-2019-0798","name":"https://talosintelligence.com/vulnerability_reports/TALOS-2019-0798","refsource":"MISC","tags":["Exploit","Third Party Advisory"],"title":"TALOS-2019-0798 ||  Cisco Talos Intelligence Group - Comprehensive Threat Intelligence","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2019-5035","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2019-5035","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2019","cve_id":"5035","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"google","cpe5":"nest_cam_iq","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"5035","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"google","cpe5":"nest_cam_iq","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"5035","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"google","cpe5":"nest_cam_iq_indoor_firmware","cpe6":"4620002","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"5035","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"google","cpe5":"nest_cam_iq_indoor_firmware","cpe6":"4620002","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"data_type":"CVE","data_format":"MITRE","data_version":"4.0","CVE_data_meta":{"ID":"CVE-2019-5035","ASSIGNER":"talos-cna@cisco.com","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"vendor_name":"n/a","product":{"product_data":[{"product_name":"Nest Labs","version":{"version_data":[{"version_value":"Nest Labs Nest Cam IQ Indoor version 4620002"}]}}]}}]}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-307: Improper Restriction of Excessive Authentication Attempts"}]}]},"references":{"reference_data":[{"refsource":"MISC","name":"https://talosintelligence.com/vulnerability_reports/TALOS-2019-0798","url":"https://talosintelligence.com/vulnerability_reports/TALOS-2019-0798"}]},"description":{"description_data":[{"lang":"eng","value":"An exploitable information disclosure vulnerability exists in the Weave PASE pairing functionality of the Nest Cam IQ Indoor, version 4620002. A set of specially crafted weave packets can brute force a pairing code, resulting in greater Weave access and potentially full device control. An attacker can send specially crafted packets to trigger this vulnerability."}]},"impact":{"cvss":{"baseScore":9,"baseSeverity":"Critical","vectorString":"CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H","version":"3.0"}}},"nvd":{"publishedDate":"2019-08-20 22:15:00","lastModifiedDate":"2022-06-27 17:28:00","problem_types":["CWE-327"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H","attackVector":"NETWORK","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"NONE","scope":"CHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":9,"baseSeverity":"CRITICAL"},"exploitabilityScore":2.2,"impactScore":6},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:P/I:P/A:P","accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL","baseScore":6.8},"severity":"MEDIUM","exploitabilityScore":8.6,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:google:nest_cam_iq_indoor_firmware:4620002:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:google:nest_cam_iq:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":{"CveYear":"2019","CveId":"5035","Ordinal":"142651","Title":"CVE-2019-5035","CVE":"CVE-2019-5035","Year":"2019"},"notes":[{"CveYear":"2019","CveId":"5035","Ordinal":"1","NoteData":"An exploitable information disclosure vulnerability exists in the Weave PASE pairing functionality of the Nest Cam IQ Indoor, version 4620002. A set of specially crafted weave packets can brute force a pairing code, resulting in greater Weave access and potentially full device control. An attacker can send specially crafted packets to trigger this vulnerability.","Type":"Description","Title":null},{"CveYear":"2019","CveId":"5035","Ordinal":"2","NoteData":"2019-08-20","Type":"Other","Title":"Published"},{"CveYear":"2019","CveId":"5035","Ordinal":"3","NoteData":"2019-08-20","Type":"Other","Title":"Modified"}]}}}