{"api_version":"1","generated_at":"2026-04-23T00:40:21+00:00","cve":"CVE-2019-6585","urls":{"html":"https://cve.report/CVE-2019-6585","api":"https://cve.report/api/cve/CVE-2019-6585.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2019-6585","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2019-6585"},"summary":{"title":"CVE-2019-6585","description":"A vulnerability has been identified in SCALANCE S602 (All versions >= V3.0 and < V4.1), SCALANCE S612 (All versions >= V3.0 and < V4.1), SCALANCE S623 (All versions >= V3.0 and < V4.1), SCALANCE S627-2M (All versions >= V3.0 and < V4.1). The integrated configuration web server of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed.","state":"PUBLIC","assigner":"productcert@siemens.com","published_at":"2020-03-10 20:15:00","updated_at":"2023-04-25 18:25:00"},"problem_types":["CWE-80"],"metrics":[],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf","name":"https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf","refsource":"MISC","tags":["Vendor Advisory"],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"0"},{"url":"https://www.us-cert.gov/ics/advisories/icsa-20-042-10","name":"https://www.us-cert.gov/ics/advisories/icsa-20-042-10","refsource":"MISC","tags":[],"title":"Siemens SCALANCE S-600 (Update A) | CISA","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2019-6585","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2019-6585","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2019","cve_id":"6585","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"scalance_s602","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"6585","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"scalance_s602","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"6585","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"scalance_s602_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"6585","vulnerable":"1","versionEndIncluding":"3.0","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"scalance_s602_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"6585","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"scalance_s612","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"6585","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"scalance_s612","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"6585","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"scalance_s612_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"6585","vulnerable":"1","versionEndIncluding":"3.0","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"scalance_s612_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"6585","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"scalance_s623","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"6585","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"scalance_s623","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"6585","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"scalance_s623_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"6585","vulnerable":"1","versionEndIncluding":"3.0","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"scalance_s623_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"6585","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"scalance_s627-2m","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"6585","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"scalance_s627-2m","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"6585","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"scalance_s627-2m_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"6585","vulnerable":"1","versionEndIncluding":"3.0","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"scalance_s627-2m_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[{"cve":"CVE-2019-6585","qid":"590389","title":"Siemens SCALANCE S-600 (Update B) Multiple Vulnerabilities (ICSA-20-042-10)"}]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"productcert@siemens.com","ID":"CVE-2019-6585","STATE":"PUBLIC"},"data_format":"MITRE","data_version":"4.0","data_type":"CVE","affects":{"vendor":{"vendor_data":[{"vendor_name":"Siemens","product":{"product_data":[{"product_name":"SCALANCE S602","version":{"version_data":[{"version_value":"All versions >= V3.0 and < V4.1"}]}},{"product_name":"SCALANCE S612","version":{"version_data":[{"version_value":"All versions >= V3.0 and < V4.1"}]}},{"product_name":"SCALANCE S623","version":{"version_data":[{"version_value":"All versions >= V3.0 and < V4.1"}]}},{"product_name":"SCALANCE S627-2M","version":{"version_data":[{"version_value":"All versions >= V3.0 and < V4.1"}]}}]}}]}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)"}]}]},"description":{"description_data":[{"lang":"eng","value":"A vulnerability has been identified in SCALANCE S602 (All versions >= V3.0 and < V4.1), SCALANCE S612 (All versions >= V3.0 and < V4.1), SCALANCE S623 (All versions >= V3.0 and < V4.1), SCALANCE S627-2M (All versions >= V3.0 and < V4.1). The integrated configuration web server of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed."}]},"references":{"reference_data":[{"refsource":"CONFIRM","name":"https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf","url":"https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf"},{"refsource":"MISC","name":"https://www.us-cert.gov/ics/advisories/icsa-20-042-10","url":"https://www.us-cert.gov/ics/advisories/icsa-20-042-10"}]}},"nvd":{"publishedDate":"2020-03-10 20:15:00","lastModifiedDate":"2023-04-25 18:25:00","problem_types":["CWE-80"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"CHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"NONE","baseScore":6.1,"baseSeverity":"MEDIUM"},"exploitabilityScore":2.8,"impactScore":2.7},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:N/I:P/A:N","accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"PARTIAL","availabilityImpact":"NONE","baseScore":4.3},"severity":"MEDIUM","exploitabilityScore":8.6,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:scalance_s602_firmware:*:*:*:*:*:*:*:*","versionStartIncluding":"3.0","versionEndExcluding":"4.1","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:siemens:scalance_s602:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:scalance_s612_firmware:*:*:*:*:*:*:*:*","versionStartIncluding":"3.0","versionEndExcluding":"4.1","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:siemens:scalance_s612:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:scalance_s623_firmware:*:*:*:*:*:*:*:*","versionStartIncluding":"3.0","versionEndExcluding":"4.1","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:siemens:scalance_s623:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:scalance_s627-2m_firmware:*:*:*:*:*:*:*:*","versionStartIncluding":"3.0","versionEndExcluding":"4.1","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:siemens:scalance_s627-2m:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":{"CveYear":"2019","CveId":"6585","Ordinal":"144316","Title":"CVE-2019-6585","CVE":"CVE-2019-6585","Year":"2019"},"notes":[{"CveYear":"2019","CveId":"6585","Ordinal":"1","NoteData":"A vulnerability has been identified in SCALANCE S602 (All versions >= V3.0 and < V4.1), SCALANCE S612 (All versions >= V3.0 and < V4.1), SCALANCE S623 (All versions >= V3.0 and < V4.1), SCALANCE S627-2M (All versions >= V3.0 and < V4.1). The integrated configuration web server of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed.","Type":"Description","Title":null},{"CveYear":"2019","CveId":"6585","Ordinal":"2","NoteData":"2020-03-10","Type":"Other","Title":"Published"},{"CveYear":"2019","CveId":"6585","Ordinal":"3","NoteData":"2021-04-22","Type":"Other","Title":"Modified"}]}}}