{"api_version":"1","generated_at":"2026-07-23T09:41:31+00:00","cve":"CVE-2019-6812","urls":{"html":"https://cve.report/CVE-2019-6812","api":"https://cve.report/api/cve/CVE-2019-6812.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2019-6812","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2019-6812"},"summary":{"title":"CVE-2019-6812","description":"A CWE-798 use of hardcoded credentials vulnerability exists in BMX-NOR-0200H with firmware versions prior to V1.7 IR 19 which could cause a confidentiality issue when using FTP protocol.","state":"PUBLIC","assigner":"cybersecurity@schneider-electric.com","published_at":"2019-05-22 20:29:00","updated_at":"2022-10-14 02:55:00"},"problem_types":["CWE-798"],"metrics":[],"references":[{"url":"https://security.cse.iitk.ac.in/responsible-disclosure","name":"https://security.cse.iitk.ac.in/responsible-disclosure","refsource":"MISC","tags":[],"title":"Responsible Disclosure | Indian Institute of Technology, Kanpur","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.schneider-electric.com/en/download/document/SEVD-2019-134-06/","name":"https://www.schneider-electric.com/en/download/document/SEVD-2019-134-06/","refsource":"MISC","tags":["Vendor Advisory"],"title":"Security Notification - Modicon RTU Module | Schneider Electric","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2019-6812","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2019-6812","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2019","cve_id":"6812","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"schneider-electric","cpe5":"bmx-nor-0200h","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"6812","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"schneider-electric","cpe5":"bmx-nor-0200h","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"6812","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"schneider-electric","cpe5":"bmx-nor-0200h_firmware","cpe6":"1.7","cpe7":"ir17","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"6812","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"schneider-electric","cpe5":"bmx-nor-0200h_firmware","cpe6":"1.7","cpe7":"ir18","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"6812","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"schneider-electric","cpe5":"bmx-nor-0200h_firmware","cpe6":"1.7","cpe7":"ir17","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"6812","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"schneider-electric","cpe5":"bmx-nor-0200h_firmware","cpe6":"1.7","cpe7":"ir18","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[{"cve":"CVE-2019-6812","qid":"590825","title":"Schneider Electric Modicon RTU Module Vulnerability (SEVD-2019-134-06)"}]},"source_records":{"cve_program":{"data_type":"CVE","data_format":"MITRE","data_version":"4.0","CVE_data_meta":{"ID":"CVE-2019-6812","ASSIGNER":"cybersecurity@schneider-electric.com","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"vendor_name":"n/a","product":{"product_data":[{"product_name":"Modicon RTU Module, BMX-NOR-0200H with firmware versions prior to V1.7 IR 19","version":{"version_data":[{"version_value":"Modicon RTU Module, BMX-NOR-0200H with firmware versions prior to V1.7 IR 19"}]}}]}}]}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-798: Use of hardcoded credentials"}]}]},"references":{"reference_data":[{"refsource":"MISC","name":"https://www.schneider-electric.com/en/download/document/SEVD-2019-134-06/","url":"https://www.schneider-electric.com/en/download/document/SEVD-2019-134-06/"},{"refsource":"MISC","name":"https://security.cse.iitk.ac.in/responsible-disclosure","url":"https://security.cse.iitk.ac.in/responsible-disclosure"}]},"description":{"description_data":[{"lang":"eng","value":"A CWE-798 use of hardcoded credentials vulnerability exists in BMX-NOR-0200H with firmware versions prior to V1.7 IR 19 which could cause a confidentiality issue when using FTP protocol."}]}},"nvd":{"publishedDate":"2019-05-22 20:29:00","lastModifiedDate":"2022-10-14 02:55:00","problem_types":["CWE-798"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":7.2,"baseSeverity":"HIGH"},"exploitabilityScore":1.2,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:L/Au:S/C:P/I:N/A:N","accessVector":"NETWORK","accessComplexity":"LOW","authentication":"SINGLE","confidentialityImpact":"PARTIAL","integrityImpact":"NONE","availabilityImpact":"NONE","baseScore":4},"severity":"MEDIUM","exploitabilityScore":8,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:schneider-electric:bmx-nor-0200h_firmware:1.7:ir17:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:schneider-electric:bmx-nor-0200h_firmware:1.7:ir18:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:schneider-electric:bmx-nor-0200h:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":{"CveYear":"2019","CveId":"6812","Ordinal":"144546","Title":"CVE-2019-6812","CVE":"CVE-2019-6812","Year":"2019"},"notes":[{"CveYear":"2019","CveId":"6812","Ordinal":"1","NoteData":"A CWE-798 use of hardcoded credentials vulnerability exists in BMX-NOR-0200H with firmware versions prior to V1.7 IR 19 which could cause a confidentiality issue when using FTP protocol.","Type":"Description","Title":null},{"CveYear":"2019","CveId":"6812","Ordinal":"2","NoteData":"2019-05-22","Type":"Other","Title":"Published"},{"CveYear":"2019","CveId":"6812","Ordinal":"3","NoteData":"2019-10-02","Type":"Other","Title":"Modified"}]}}}