{"api_version":"1","generated_at":"2026-07-23T08:39:45+00:00","cve":"CVE-2019-7670","urls":{"html":"https://cve.report/CVE-2019-7670","api":"https://cve.report/api/cve/CVE-2019-7670.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2019-7670","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2019-7670"},"summary":{"title":"CVE-2019-7670","description":"Prima Systems FlexAir, Versions 2.3.38 and prior. The application incorrectly neutralizes special elements that could modify the intended OS command when it is sent to a downstream component, which could allow attackers to execute commands directly on the operating system.","state":"PUBLIC","assigner":"cve@mitre.org","published_at":"2019-07-01 19:15:00","updated_at":"2022-10-21 19:14:00"},"problem_types":["CWE-78"],"metrics":[],"references":[{"url":"http://packetstormsecurity.com/files/155271/FlexAir-Access-Control-2.3.38-Remote-Root.html","name":"http://packetstormsecurity.com/files/155271/FlexAir-Access-Control-2.3.38-Remote-Root.html","refsource":"MISC","tags":[],"title":"FlexAir Access Control 2.3.38 Remote Root ≈ Packet Storm","mime":"text/html","httpstatus":"200","archivestatus":"0"},{"url":"https://www.applied-risk.com/resources/ar-2019-007","name":"https://www.applied-risk.com/resources/ar-2019-007","refsource":"MISC","tags":["Third Party Advisory"],"title":"Prima Systems FlexAir Multiple Vulnerabilities Prima Systems FlexAir Multiple Vulnerabilities - Applied Risk","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://applied-risk.com/labs/advisories","name":"https://applied-risk.com/labs/advisories","refsource":"MISC","tags":["Third Party Advisory"],"title":"Applied Risk :: Advisories","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.us-cert.gov/ics/advisories/icsa-19-211-02","name":"https://www.us-cert.gov/ics/advisories/icsa-19-211-02","refsource":"MISC","tags":[],"title":"Prima Systems FlexAir | CISA","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2019-7670","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2019-7670","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2019","cve_id":"7670","vulnerable":"1","versionEndIncluding":"2.3.38","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"primasystems","cpe5":"flexair","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"cve@mitre.org","ID":"CVE-2019-7670","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"n/a","version":{"version_data":[{"version_value":"n/a"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Prima Systems FlexAir, Versions 2.3.38 and prior. The application incorrectly neutralizes special elements that could modify the intended OS command when it is sent to a downstream component, which could allow attackers to execute commands directly on the operating system."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"n/a"}]}]},"references":{"reference_data":[{"url":"https://applied-risk.com/labs/advisories","refsource":"MISC","name":"https://applied-risk.com/labs/advisories"},{"refsource":"MISC","name":"https://www.us-cert.gov/ics/advisories/icsa-19-211-02","url":"https://www.us-cert.gov/ics/advisories/icsa-19-211-02"},{"refsource":"MISC","name":"http://packetstormsecurity.com/files/155271/FlexAir-Access-Control-2.3.38-Remote-Root.html","url":"http://packetstormsecurity.com/files/155271/FlexAir-Access-Control-2.3.38-Remote-Root.html"}]}},"nvd":{"publishedDate":"2019-07-01 19:15:00","lastModifiedDate":"2022-10-21 19:14:00","problem_types":["CWE-78"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":7.2,"baseSeverity":"HIGH"},"exploitabilityScore":1.2,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:L/Au:S/C:C/I:C/A:C","accessVector":"NETWORK","accessComplexity":"LOW","authentication":"SINGLE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE","baseScore":9},"severity":"HIGH","exploitabilityScore":8,"impactScore":10,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:primasystems:flexair:*:*:*:*:*:*:*:*","versionEndIncluding":"2.3.38","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2019","CveId":"7670","Ordinal":"145485","Title":"CVE-2019-7670","CVE":"CVE-2019-7670","Year":"2019"},"notes":[{"CveYear":"2019","CveId":"7670","Ordinal":"1","NoteData":"Prima Systems FlexAir, Versions 2.3.38 and prior. The application incorrectly neutralizes special elements that could modify the intended OS command when it is sent to a downstream component, which could allow attackers to execute commands directly on the operating system.","Type":"Description","Title":null},{"CveYear":"2019","CveId":"7670","Ordinal":"2","NoteData":"2019-07-01","Type":"Other","Title":"Published"},{"CveYear":"2019","CveId":"7670","Ordinal":"3","NoteData":"2019-11-12","Type":"Other","Title":"Modified"}]}}}