{"api_version":"1","generated_at":"2026-04-23T11:33:02+00:00","cve":"CVE-2019-8268","urls":{"html":"https://cve.report/CVE-2019-8268","api":"https://cve.report/api/cve/CVE-2019-8268.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2019-8268","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2019-8268"},"summary":{"title":"CVE-2019-8268","description":"UltraVNC revision 1206 has multiple off-by-one vulnerabilities in VNC client code connected with improper usage of ClientConnection::ReadString function, which can potentially result code execution. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1207.","state":"PUBLIC","assigner":"vulnerability@kaspersky.com","published_at":"2019-03-08 23:29:00","updated_at":"2020-10-19 17:56:00"},"problem_types":["CWE-193"],"metrics":[],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf","name":"https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf","refsource":"CONFIRM","tags":["Third Party Advisory"],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"0"},{"url":"https://www.us-cert.gov/ics/advisories/icsa-20-161-06","name":"https://www.us-cert.gov/ics/advisories/icsa-20-161-06","refsource":"MISC","tags":["Third Party Advisory","US Government Resource"],"title":"Siemens SINUMERIK | CISA","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-015-ultravnc-off-by-one-error/","name":"https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-015-ultravnc-off-by-one-error/","refsource":"MISC","tags":["Third Party Advisory"],"title":"KLCERT-19-015: UltraVNC Off-by-one Error | Kaspersky ICS CERT","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2019-8268","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2019-8268","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2019","cve_id":"8268","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"sinumerik_access_mymachine/p2p","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"8268","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"sinumerik_access_mymachine\\/p2p","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"8268","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"sinumerik_access_mymachine\\/p2p","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"8268","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"sinumerik_pcu_base_win10_software/ipc","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"8268","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"sinumerik_pcu_base_win10_software\\/ipc","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"8268","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"sinumerik_pcu_base_win10_software\\/ipc","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"8268","vulnerable":"1","versionEndIncluding":"12.01","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"sinumerik_pcu_base_win7_software/ipc","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"8268","vulnerable":"1","versionEndIncluding":"12.01","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"sinumerik_pcu_base_win7_software\\/ipc","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"8268","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"uvnc","cpe5":"ultravnc","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2019","cve_id":"8268","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"uvnc","cpe5":"ultravnc","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[{"cve":"CVE-2019-8268","qid":"590854","title":"Schneider Electric TelevisGo Multiple Vulnerabilities (SEVD-2019-225-05)"}]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"vulnerability@kaspersky.com","DATE_PUBLIC":"2019-03-01T00:00:00","ID":"CVE-2019-8268","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"UltraVNC","version":{"version_data":[{"version_value":"1.2.2.3"}]}}]},"vendor_name":"Kaspersky Lab"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"UltraVNC revision 1206 has multiple off-by-one vulnerabilities in VNC client code connected with improper usage of ClientConnection::ReadString function, which can potentially result code execution. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1207."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-193: Off-by-one Error"}]}]},"references":{"reference_data":[{"name":"https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-015-ultravnc-off-by-one-error/","refsource":"MISC","url":"https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-015-ultravnc-off-by-one-error/"},{"refsource":"CONFIRM","name":"https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf","url":"https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"},{"refsource":"MISC","name":"https://www.us-cert.gov/ics/advisories/icsa-20-161-06","url":"https://www.us-cert.gov/ics/advisories/icsa-20-161-06"}]}},"nvd":{"publishedDate":"2019-03-08 23:29:00","lastModifiedDate":"2020-10-19 17:56:00","problem_types":["CWE-193"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":9.8,"baseSeverity":"CRITICAL"},"exploitabilityScore":3.9,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:P/A:P","accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL","baseScore":7.5},"severity":"HIGH","exploitabilityScore":10,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:uvnc:ultravnc:*:*:*:*:*:*:*:*","versionEndExcluding":"1.2.2.3","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:sinumerik_pcu_base_win7_software\\/ipc:*:*:*:*:*:*:*:*","versionEndIncluding":"12.01","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:sinumerik_pcu_base_win10_software\\/ipc:*:*:*:*:*:*:*:*","versionEndExcluding":"14.00","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:sinumerik_access_mymachine\\/p2p:*:*:*:*:*:*:*:*","versionEndExcluding":"4.8","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2019","CveId":"8268","Ordinal":"146101","Title":"CVE-2019-8268","CVE":"CVE-2019-8268","Year":"2019"},"notes":[{"CveYear":"2019","CveId":"8268","Ordinal":"1","NoteData":"UltraVNC revision 1206 has multiple off-by-one vulnerabilities in VNC client code connected with improper usage of ClientConnection::ReadString function, which can potentially result code execution. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1207.","Type":"Description","Title":null},{"CveYear":"2019","CveId":"8268","Ordinal":"2","NoteData":"2019-03-08","Type":"Other","Title":"Published"},{"CveYear":"2019","CveId":"8268","Ordinal":"3","NoteData":"2020-06-12","Type":"Other","Title":"Modified"}]}}}