{"api_version":"1","generated_at":"2026-05-13T15:54:08+00:00","cve":"CVE-2020-10598","urls":{"html":"https://cve.report/CVE-2020-10598","api":"https://cve.report/api/cve/CVE-2020-10598.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2020-10598","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2020-10598"},"summary":{"title":"CVE-2020-10598","description":"In BD Pyxis MedStation ES System v1.6.1 and Pyxis Anesthesia (PAS) ES System v1.6.1, a restricted desktop environment escape vulnerability exists in the kiosk mode functionality of affected devices. Specially crafted inputs could allow the user to escape the restricted environment, resulting in access to sensitive data.","state":"PUBLIC","assigner":"ics-cert@hq.dhs.gov","published_at":"2020-04-01 21:15:00","updated_at":"2021-09-14 13:35:00"},"problem_types":["NVD-CWE-Other"],"metrics":[],"references":[{"url":"https://www.us-cert.gov/ics/advisories/icsma-20-091-01","name":"https://www.us-cert.gov/ics/advisories/icsma-20-091-01","refsource":"MISC","tags":["Third Party Advisory","US Government Resource"],"title":"BD Pyxis MedStation and Pyxis Anesthesia (PAS) ES System | CISA","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2020-10598","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2020-10598","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2020","cve_id":"10598","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"bd","cpe5":"pyxis_anesthesia_station_es","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"10598","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"bd","cpe5":"pyxis_anesthesia_station_es","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"10598","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"bd","cpe5":"pyxis_anesthesia_station_es_firmware","cpe6":"1.6.1","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"10598","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"bd","cpe5":"pyxis_anesthesia_station_es_firmware","cpe6":"1.6.1","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"10598","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"bd","cpe5":"pyxis_medstation_es","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"10598","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"bd","cpe5":"pyxis_medstation_es","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"10598","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"bd","cpe5":"pyxis_medstation_es_firmware","cpe6":"1.6.1","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"10598","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"bd","cpe5":"pyxis_medstation_es_firmware","cpe6":"1.6.1","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"data_type":"CVE","data_format":"MITRE","data_version":"4.0","CVE_data_meta":{"ID":"CVE-2020-10598","ASSIGNER":"ics-cert@hq.dhs.gov","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"vendor_name":"Becton, Dickinson and Company (BD)","product":{"product_data":[{"product_name":"Pyxis MedStation ES System","version":{"version_data":[{"version_value":"v1.6.1"}]}},{"product_name":"Pyxis Anesthesia (PAS) ES System","version":{"version_data":[{"version_value":"v1.6.1"}]}}]}}]}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"PROTECTION MECHANISM FAILURE CWE-693"}]}]},"references":{"reference_data":[{"refsource":"MISC","name":"https://www.us-cert.gov/ics/advisories/icsma-20-091-01","url":"https://www.us-cert.gov/ics/advisories/icsma-20-091-01"}]},"description":{"description_data":[{"lang":"eng","value":"In BD Pyxis MedStation ES System v1.6.1 and Pyxis Anesthesia (PAS) ES System v1.6.1, a restricted desktop environment escape vulnerability exists in the kiosk mode functionality of affected devices. Specially crafted inputs could allow the user to escape the restricted environment, resulting in access to sensitive data."}]}},"nvd":{"publishedDate":"2020-04-01 21:15:00","lastModifiedDate":"2021-09-14 13:35:00","problem_types":["NVD-CWE-Other"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N","attackVector":"PHYSICAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"NONE","baseScore":6.1,"baseSeverity":"MEDIUM"},"exploitabilityScore":0.9,"impactScore":5.2},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:L/AC:L/Au:N/C:P/I:P/A:N","accessVector":"LOCAL","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"NONE","baseScore":3.6},"severity":"LOW","exploitabilityScore":3.9,"impactScore":4.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:bd:pyxis_medstation_es_firmware:1.6.1:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:bd:pyxis_medstation_es:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:bd:pyxis_anesthesia_station_es_firmware:1.6.1:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:bd:pyxis_anesthesia_station_es:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":{"CveYear":"2020","CveId":"10598","Ordinal":"171017","Title":"CVE-2020-10598","CVE":"CVE-2020-10598","Year":"2020"},"notes":[{"CveYear":"2020","CveId":"10598","Ordinal":"1","NoteData":"In BD Pyxis MedStation ES System v1.6.1 and Pyxis Anesthesia (PAS) ES System v1.6.1, a restricted desktop environment escape vulnerability exists in the kiosk mode functionality of affected devices. Specially crafted inputs could allow the user to escape the restricted environment, resulting in access to sensitive data.","Type":"Description","Title":null},{"CveYear":"2020","CveId":"10598","Ordinal":"2","NoteData":"2020-04-01","Type":"Other","Title":"Published"},{"CveYear":"2020","CveId":"10598","Ordinal":"3","NoteData":"2020-04-01","Type":"Other","Title":"Modified"}]}}}