{"api_version":"1","generated_at":"2026-07-23T14:46:56+00:00","cve":"CVE-2020-10611","urls":{"html":"https://cve.report/CVE-2020-10611","api":"https://cve.report/api/cve/CVE-2020-10611.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2020-10611","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2020-10611"},"summary":{"title":"CVE-2020-10611","description":"Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type confusion condition. Authentication is not required to exploit this vulnerability. Only applicable to installations using DNP3 Data Sets.","state":"PUBLIC","assigner":"ics-cert@hq.dhs.gov","published_at":"2020-04-15 19:15:00","updated_at":"2020-04-22 17:32:00"},"problem_types":["CWE-843"],"metrics":[],"references":[{"url":"https://www.zerodayinitiative.com/advisories/ZDI-20-549/","name":"https://www.zerodayinitiative.com/advisories/ZDI-20-549/","refsource":"MISC","tags":["Third Party Advisory","VDB Entry"],"title":"ZDI-20-549 | Zero Day Initiative","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.us-cert.gov/ics/advisories/icsa-20-105-03","name":"https://www.us-cert.gov/ics/advisories/icsa-20-105-03","refsource":"MISC","tags":["Third Party Advisory","US Government Resource"],"title":"Triangle MicroWorks SCADA Data Gateway  | CISA","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2020-10611","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2020-10611","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2020","cve_id":"10611","vulnerable":"1","versionEndIncluding":"4.0.122","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trianglemicroworks","cpe5":"scada_data_gateway","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"data_type":"CVE","data_format":"MITRE","data_version":"4.0","CVE_data_meta":{"ID":"CVE-2020-10611","ASSIGNER":"ics-cert@hq.dhs.gov","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"vendor_name":"n/a","product":{"product_data":[{"product_name":"Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122","version":{"version_data":[{"version_value":"Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122"}]}}]}}]}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"ACCESS OF RESOURCE USING INCOMPATIBLE TYPE ('TYPE CONFUSION') CWE-843"}]}]},"references":{"reference_data":[{"refsource":"MISC","name":"https://www.us-cert.gov/ics/advisories/icsa-20-105-03","url":"https://www.us-cert.gov/ics/advisories/icsa-20-105-03"},{"refsource":"MISC","name":"https://www.zerodayinitiative.com/advisories/ZDI-20-549/","url":"https://www.zerodayinitiative.com/advisories/ZDI-20-549/"}]},"description":{"description_data":[{"lang":"eng","value":"Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type confusion condition. Authentication is not required to exploit this vulnerability. Only applicable to installations using DNP3 Data Sets."}]}},"nvd":{"publishedDate":"2020-04-15 19:15:00","lastModifiedDate":"2020-04-22 17:32:00","problem_types":["CWE-843"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":9.8,"baseSeverity":"CRITICAL"},"exploitabilityScore":3.9,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:P/A:P","accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL","baseScore":7.5},"severity":"HIGH","exploitabilityScore":10,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:*:*:*:*:*:*:*:*","versionStartIncluding":"2.41.0213","versionEndIncluding":"4.0.122","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2020","CveId":"10611","Ordinal":"171030","Title":"CVE-2020-10611","CVE":"CVE-2020-10611","Year":"2020"},"notes":[{"CveYear":"2020","CveId":"10611","Ordinal":"1","NoteData":"Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type confusion condition. Authentication is not required to exploit this vulnerability. Only applicable to installations using DNP3 Data Sets.","Type":"Description","Title":null},{"CveYear":"2020","CveId":"10611","Ordinal":"2","NoteData":"2020-04-15","Type":"Other","Title":"Published"},{"CveYear":"2020","CveId":"10611","Ordinal":"3","NoteData":"2020-04-16","Type":"Other","Title":"Modified"}]}}}