{"api_version":"1","generated_at":"2026-07-04T17:21:44+00:00","cve":"CVE-2020-12004","urls":{"html":"https://cve.report/CVE-2020-12004","api":"https://cve.report/api/cve/CVE-2020-12004.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2020-12004","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2020-12004"},"summary":{"title":"CVE-2020-12004","description":"The affected product lacks proper authentication required to query the server on the Ignition 8 Gateway (versions prior to 8.0.10) and Ignition 7 Gateway (versions prior to 7.9.14), allowing an attacker to obtain sensitive information.","state":"PUBLIC","assigner":"ics-cert@hq.dhs.gov","published_at":"2020-06-09 18:15:00","updated_at":"2020-06-25 23:15:00"},"problem_types":["CWE-306"],"metrics":[],"references":[{"url":"https://www.us-cert.gov/ics/advisories/icsa-20-147-01","name":"https://www.us-cert.gov/ics/advisories/icsa-20-147-01","refsource":"MISC","tags":["Third Party Advisory","US Government Resource"],"title":"Inductive Automation Ignition (Update A) | CISA","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"http://packetstormsecurity.com/files/158226/Inductive-Automation-Ignition-Remote-Code-Execution.html","name":"http://packetstormsecurity.com/files/158226/Inductive-Automation-Ignition-Remote-Code-Execution.html","refsource":"MISC","tags":[],"title":"Inductive Automation Ignition Remote Code Execution ≈ Packet Storm","mime":"text/html","httpstatus":"200","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2020-12004","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2020-12004","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2020","cve_id":"12004","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"inductiveautomation","cpe5":"ignition_gateway","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"12004","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"inductiveautomation","cpe5":"ignition_gateway","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"data_type":"CVE","data_format":"MITRE","data_version":"4.0","CVE_data_meta":{"ID":"CVE-2020-12004","ASSIGNER":"ics-cert@hq.dhs.gov","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"vendor_name":"n/a","product":{"product_data":[{"product_name":"Ignition 8 Gateway","version":{"version_data":[{"version_value":"versions prior to 7.9.14 and 8.0.10"}]}}]}}]}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"MISSING AUTHENTICATION FOR CRITICAL FUNCTION CWE-306"}]}]},"references":{"reference_data":[{"refsource":"MISC","name":"https://www.us-cert.gov/ics/advisories/icsa-20-147-01","url":"https://www.us-cert.gov/ics/advisories/icsa-20-147-01"},{"refsource":"MISC","name":"http://packetstormsecurity.com/files/158226/Inductive-Automation-Ignition-Remote-Code-Execution.html","url":"http://packetstormsecurity.com/files/158226/Inductive-Automation-Ignition-Remote-Code-Execution.html"}]},"description":{"description_data":[{"lang":"eng","value":"The affected product lacks proper authentication required to query the server on the Ignition 8 Gateway (versions prior to 8.0.10) and Ignition 7 Gateway (versions prior to 7.9.14), allowing an attacker to obtain sensitive information."}]}},"nvd":{"publishedDate":"2020-06-09 18:15:00","lastModifiedDate":"2020-06-25 23:15:00","problem_types":["CWE-306"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE","baseScore":7.5,"baseSeverity":"HIGH"},"exploitabilityScore":3.9,"impactScore":3.6},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:N/A:N","accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"NONE","availabilityImpact":"NONE","baseScore":5},"severity":"MEDIUM","exploitabilityScore":10,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:inductiveautomation:ignition_gateway:*:*:*:*:*:*:*:*","versionStartIncluding":"8.0","versionEndExcluding":"8.0.10","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:inductiveautomation:ignition_gateway:*:*:*:*:*:*:*:*","versionStartIncluding":"7.2.4.48","versionEndExcluding":"7.9.14","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2020","CveId":"12004","Ordinal":"173142","Title":"CVE-2020-12004","CVE":"CVE-2020-12004","Year":"2020"},"notes":[{"CveYear":"2020","CveId":"12004","Ordinal":"1","NoteData":"The affected product lacks proper authentication required to query the server on the Ignition 8 Gateway (versions prior to 8.0.10) and Ignition 7 Gateway (versions prior to 7.9.14), allowing an attacker to obtain sensitive information.","Type":"Description","Title":null},{"CveYear":"2020","CveId":"12004","Ordinal":"2","NoteData":"2020-06-09","Type":"Other","Title":"Published"},{"CveYear":"2020","CveId":"12004","Ordinal":"3","NoteData":"2020-06-25","Type":"Other","Title":"Modified"}]}}}