{"api_version":"1","generated_at":"2026-04-23T15:29:07+00:00","cve":"CVE-2020-12518","urls":{"html":"https://cve.report/CVE-2020-12518","api":"https://cve.report/api/cve/CVE-2020-12518.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2020-12518","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2020-12518"},"summary":{"title":"CVE-2020-12518","description":"On Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS an attacker can use the knowledge gained by reading the insufficiently protected sensitive information to plan further attacks.","state":"PUBLIC","assigner":"info@cert.vde.com","published_at":"2020-12-17 23:15:00","updated_at":"2020-12-21 18:30:00"},"problem_types":["CWE-200"],"metrics":[],"references":[{"url":"https://cert.vde.com/en-us/advisories/vde-2020-049","name":"https://cert.vde.com/en-us/advisories/vde-2020-049","refsource":"CONFIRM","tags":["Third Party Advisory"],"title":"PHOENIX CONTACT: Multiple vulnerabilities in PLCnext Control devices — English (USA)","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2020-12518","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2020-12518","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[{"source":"LEGACY","value":"Discovered by Patrick Muench, Torsten Loebner, Maurice Rothe, Pascal Keul and Daniel Hackel of SVA Systemvertrieb Alexander GmbH, coordinated by CERT@VDE","lang":""}],"nvd_cpes":[{"cve_year":"2020","cve_id":"12518","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"phoenixcontact","cpe5":"axc_f_1152","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"12518","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"phoenixcontact","cpe5":"axc_f_1152","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"12518","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"phoenixcontact","cpe5":"axc_f_2152","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"12518","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"phoenixcontact","cpe5":"axc_f_2152","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"12518","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"phoenixcontact","cpe5":"axc_f_2152_starterkit","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"12518","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"phoenixcontact","cpe5":"axc_f_2152_starterkit","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"12518","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"phoenixcontact","cpe5":"axc_f_3152","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"12518","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"phoenixcontact","cpe5":"axc_f_3152","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"12518","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"phoenixcontact","cpe5":"plcnext_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"long_term_support","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"12518","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"phoenixcontact","cpe5":"plcnext_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"long_term_support","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"12518","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"phoenixcontact","cpe5":"plcnext_technology_starterkit","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"12518","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"phoenixcontact","cpe5":"plcnext_technology_starterkit","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"12518","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"phoenixcontact","cpe5":"rfc_4072s","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"12518","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"phoenixcontact","cpe5":"rfc_4072s","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"data_type":"CVE","data_format":"MITRE","data_version":"4.0","generator":{"engine":"Vulnogram 0.0.9"},"CVE_data_meta":{"ID":"CVE-2020-12518","ASSIGNER":"info@cert.vde.com","DATE_PUBLIC":"2020-12-17T09:00:00.000Z","TITLE":"Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS: An attacker can use the knowledge gained by reading the insufficiently protected sensitive information to plan further attacks.","AKA":"","STATE":"PUBLIC"},"source":{"defect":["VDE-2020-049"],"advisory":"VDE-2020-049","discovery":"EXTERNAL"},"affects":{"vendor":{"vendor_data":[{"vendor_name":"Phoenix Contact","product":{"product_data":[{"product_name":"AXC F 1152 (1151412)","version":{"version_data":[{"version_name":"","version_affected":"<","version_value":"2021.0 LTS","platform":""}]}},{"product_name":"AXC F 2152 (2404267)","version":{"version_data":[{"version_name":"","version_affected":"<","version_value":"2021.0 LTS","platform":""}]}},{"product_name":"AXC F 3152 (1069208)","version":{"version_data":[{"version_name":"","version_affected":"<","version_value":"2021.0 LTS","platform":""}]}},{"product_name":"RFC 4072S (1051328","version":{"version_data":[{"version_name":"","version_affected":"<","version_value":"2021.0 LTS","platform":""}]}},{"product_name":"AXC F 2152 Starterkit (1046568)","version":{"version_data":[{"version_name":"","version_affected":"<","version_value":"2021.0 LTS","platform":""}]}},{"product_name":"PLCnext Technology Starterkit (1188165)","version":{"version_data":[{"version_name":"","version_affected":"<","version_value":"2021.0 LTS","platform":""}]}}]}}]}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-200 Information Exposure"}]}]},"description":{"description_data":[{"lang":"eng","value":"On Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS an attacker can use the knowledge gained by reading the insufficiently protected sensitive information to plan further attacks."}]},"references":{"reference_data":[{"refsource":"CONFIRM","url":"https://cert.vde.com/en-us/advisories/vde-2020-049","name":"https://cert.vde.com/en-us/advisories/vde-2020-049"}]},"configuration":[],"impact":{"cvss":{"version":"3.1","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N","baseScore":5.5,"baseSeverity":"MEDIUM"}},"exploit":[],"work_around":[{"lang":"eng","value":"Phoenix Contact recommends operating network-capable devices in closed networks or protected with a suitable firewall. For detailed information on our recommendations for measures to protect network-capable devices, please refer to the Phoenix Contact application note."}],"solution":[{"lang":"eng","value":"Phoenix Contact recommends affected users to upgrade to the current Firmware 2021.0 LTS or higher which fixes these vulnerabilities."}],"credit":[{"lang":"eng","value":"Discovered by Patrick Muench, Torsten Loebner, Maurice Rothe, Pascal Keul and Daniel Hackel of SVA Systemvertrieb Alexander GmbH, coordinated by CERT@VDE"}]},"nvd":{"publishedDate":"2020-12-17 23:15:00","lastModifiedDate":"2020-12-21 18:30:00","problem_types":["CWE-200"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE","baseScore":5.5,"baseSeverity":"MEDIUM"},"exploitabilityScore":1.8,"impactScore":3.6},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:N/A:N","accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"NONE","availabilityImpact":"NONE","baseScore":5},"severity":"MEDIUM","exploitabilityScore":10,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:phoenixcontact:plcnext_firmware:*:*:*:*:long_term_support:*:*:*","versionEndExcluding":"2021.0","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:phoenixcontact:axc_f_1152:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:phoenixcontact:plcnext_firmware:*:*:*:*:long_term_support:*:*:*","versionEndExcluding":"2021.0","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:phoenixcontact:axc_f_2152:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:phoenixcontact:plcnext_firmware:*:*:*:*:long_term_support:*:*:*","versionEndExcluding":"2021.0","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:phoenixcontact:axc_f_3152:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:phoenixcontact:plcnext_firmware:*:*:*:*:long_term_support:*:*:*","versionEndExcluding":"2021.0","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:phoenixcontact:rfc_4072s:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:phoenixcontact:plcnext_firmware:*:*:*:*:long_term_support:*:*:*","versionEndExcluding":"2021.0","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:phoenixcontact:axc_f_2152_starterkit:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:phoenixcontact:plcnext_firmware:*:*:*:*:long_term_support:*:*:*","versionEndExcluding":"2021.0","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:phoenixcontact:plcnext_technology_starterkit:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":{"CveYear":"2020","CveId":"12518","Ordinal":"173683","Title":"CVE-2020-12518","CVE":"CVE-2020-12518","Year":"2020"},"notes":[{"CveYear":"2020","CveId":"12518","Ordinal":"1","NoteData":"On Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS an attacker can use the knowledge gained by reading the insufficiently protected sensitive information to plan further attacks.","Type":"Description","Title":null},{"CveYear":"2020","CveId":"12518","Ordinal":"2","NoteData":"2020-12-17","Type":"Other","Title":"Published"},{"CveYear":"2020","CveId":"12518","Ordinal":"3","NoteData":"2020-12-17","Type":"Other","Title":"Modified"}]}}}